Partial Discharge Calibrators
See Also: Partial Discharge Detectors
-
Product
Digital Light Meter, Calibrated
93-172-C
-
Measures incandescent, fluorescent, metal halide, high-pressure sodium and halogen lampoutput. Color and cosine-corrected for enhanced accuracy. Measures up to 50,000 lux. Peak and data hold means no lost measurements. Accessories included: (1) 9V battery and carrying case. Lifetime Limited Warranty.
-
Product
Temperature Calibration
-
Process Instruments maintains primary temperature standards for the calibration of Standard Platinum Resistance Thermometers. SPRT''s are measured against a Thomas-type Ten Ohm Standard Resistor (a Leeds & Northrup 4211-B), using a Measurements International automated bridge. Primary thermometry points are maintained at the Water, Tin, Zinc and Gallium points.
-
Product
Intelligent Digital Multimeter, Calibrated, 3999 Count, Mean Value, Auto, Manual Range, 3.75 Digit
72-7755 CAL DU
-
The 72-7755 CAL DU from Tenma is an intelligent digital multimeter. It has auto range or manual range options and dual display with maximum reading 3,999 displayed in 40 analogue bars in scale making the measured value to be seen clearly and indicating the trend of changing quickly. In addition to conventional measuring functions, there is a new breakthrough in frequency test with maximum range of 400MHz. RS232C standard serial port is equipped with meter for easy connection with computer to realize macro recording and monitoring and capture of transient dynamic data, displaying change of waveform during measurement, providing data and evidence to engineering technicians for scientific research. This is also a highly applied digital multimeter of high performance with full input protection and display backlight. The orange and grey colour meter features 73mm × 50mm size LCD, CAT III 1000V and CAT IV 600V safety ratings.
-
Product
Trace-Level Photometric Ozone Calibrator
Model T703U
-
Teledyne Advanced Pollution Instrumentation
The Model T703U is a microprocessor controlled ozone calibrator for precision gas analyzers. Expanded ozone audit levels have created a need for precise ozone calibration well below the capabilities of standard calibrators. The Model T703U is designed to meet the requirements of ultra-low ozone production.In addition to a high range with similar performance to the Model T703, the Model T703U has the capability to generate ozone in a low range, or "fractional" mode, for producing ozone levels down to 3 ppb, with exceptional accuracy. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperature and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703U, covering time periods up to a year.
-
Product
Calibration Hex Step Adapters
-
When performing torque wrench calibration or testing, adapters are often needed, especially with torque wrenches that have open-end heads. Mountz’s calibration hex step adapter features four common sizes, which will increase the productivity of your torque wrench calibration process. This adapter will make testing and calibration simple and efficient.
-
Product
Partial Discharge Testing Of Transformer & Localization System
AE-150™
-
The is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors' data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors.
-
Product
Argon Calibration Source
AR-1
-
The AR-1 produces low-pressure argon emission lines from 696-1704 nm for use in performing fast, reliable spectrometer wavelength calibrations.
-
Product
Calibrator, Calibrated w/Data, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL D
-
The 72-6694 CAL D from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
IEC60068-2-75 Spring Hammer Calibration Device
-
Shenzhen Chuangxin Instruments Co., Ltd.
It is mainly used for the calibration of the spring hammer, which is based on IEC60068-2-75-1997 and GB2423.55-2006 standard design and manufacture, primarily for third-party testing organization, the National immigration department and appliance-related research institutes.
-
Product
ECPR System (Electrically Calibrated Pyroelectric Radiometer)
Rs-5900
-
Developed in conjunction with NIST, the Rs-5900 ECPR is a ±1% absolute accuracy radiometric transfer standard for the visible to near-IR (0.25-2.0µm), with the RsIR Option extending the ±1% accuracy to >20µm. The RsP-590 Pyroelectric Probe requires no cooling and maintains ±1% accuracy from 1 µW to 100 mW. The ECPR uses an auto-nulling, electrical substitution technique that allows the instrument to be referenced against NIST electrical standards, insuring maximum accuracy and precision. Unlike most electrically calibrated radiometers, there is a direct correlation between electrical and optical heating because the same material serves as both the optical absorber and electrical heating element.
-
Product
Light / Lux Meter, Calibrated, 50000 lx, 100 lx, 4 %, 185 mm, 78 mm, 38 mm
72-7250 CAL
-
The 72-7250 CAL from Tenma is a digital light meter with RS232 capability. It has custom one-chip microprocessor LSI circuit which ensures high accuracy. The meter features 13mm (0.5”) super large LCD display with contrast adjustment for best viewing angle, data hold and auto power off. It records maximum, minimum and average readings with RECALL facility. The 72-7250 has RS-232 PC serial interface, user selectable lighting type (tungsten, fluorescent, sodium or mercury, daylight) and zero adjustment by push button. The meter operates from 9V battery.
-
Product
CableEye 4-Wire Calibration Verification Board | Cable & Harness Testers
CB52
-
The CB52 is intended for periodic calibration verification of the Kelvin 4-wire resistance measurement module – an optional, add-on module that may be purchased with any new hipot system, or added to an existing high voltage tester as an upgrade.
-
Product
Calibration Lead Precision Resistor - Single
40-975-009-SL1
-
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
Calibration Software
-
Calibration software is available to automate all or part of many calibration processes, manage calibration and asset data, and perform other useful tasks as well. Fluke Calibration offers a variety of market leading software applications in each of its product disciplines.
-
Product
Calibrators/ Digital Manometers
-
Meriam has earned the reputation as a world leader in the accuracy of our calibrators and digital manometers. We offer excellent hand held performance at a value price. Features include min/max capture, data record, pressure measurement, averaging and timed pressure tests. "Smart" digital manometers are well suited for field measurement and process control.
-
Product
Robot Calibration
-
Achieve improved absolute robot positioning accuracy via dynamic robot calibration using API’s Laser Tracker and Active Target a self-orienting motorized 360° rotation SMR.
-
Product
Multifunction Calibrators
-
Easy-to-use Multipurpose instruments for advanced documented calibration and process control.
-
Product
Transducer Calibration
-
When it comes to finding the perfect transducer calibration system, look no further than MB Dynamics. Our Calibration Systems offer an extensive range, from the Win475-Basic, the trusted calibration solution for the United States Air Force; to the first of its kind Win475-TS, which measures a transducer’s transverse sensitivity. No matter what your needs, you’ll find the calibration equipment that works for you.
-
Product
Standard Voltage 9 Pin D-Type Cables - Calibration Cables for Pickering Products
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 9-pin D-type calibration port connector.
-
Product
Cryostat Calibrators
-
Electronic Development Labs, Inc.
Specialized, low-temperature, passively cooled, or liquid nitrogen-based apparatuses designed to calibrate temperature sensors (RTDs, thermocouples, PRTs) at cryogenic levels.
-
Product
Calibration Plates
-
MVTec provides precision-manufactured calibration plates to its customers. The plates are necessary to accurately calibrate a machine vision setup. MVTec’s calibration plates are available in different materials and in sizes ranging from 2cm×2cm up to 32cm×32cm. Contact your local distributor for assistance with choosing the right plate size and material for your application.
-
Product
Balanced and UFL Calibration Kit
CAL-UFL-BAL
-
The Balanced Calibration Kit is an interface kit for UFL and balanced VNA measurements. It contains SMA-UFL adapters and several adapters from SMA and UFL to balanced pinheaders. The UFL connector was introduced by Hirose as the U.FL connector and became very popular for connecting RF signals in consumer electronics. There are several varieties from other manufacturors and are also known as UMC or UMCC connectors.
-
Product
Automatic Calibration Module
ACM4520
-
ACM4520 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 20 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
Product
RF Calibration Accessories
-
Employing good connector practice when using an RF calibrator not only avoids measurement errors and minimizes connector repeatability uncertainties but also reduces risk of damage to connectors and equipment. The 96000CONN and 9600CONN connector kits include a range of adapters and torque wrenches intended for use with the 96000 Series RF Reference Sources (9600CONN for the 96040A and 96000CONN for the 96270).The 9600CONN connector kit includes one each of 50 Ω and 75 N-Type male-female adapter for use with the 96000 Series levelling head as a “connector saver” or “sacrificial connector” to avoid risk of damage when making connections to UUT/DUT instruments.
-
Product
Instrument Transformer Calibrators
CTPT 81
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
Product
Trace-Level Dilution Calibrator
Model T700U
-
Teledyne Advanced Pollution Instrumentation
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.
-
Product
Calibrator
-
Sanwa Electric Instrument Co., Ltd
Is an equipment used to adjust an instrument accuracy, often associated with a specific application: temperature, pressure, weight.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (f)
85561A
Mechanical Calibration Kit
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight.
-
Product
Portable Calibration Shaker Table
AT-2030
-
The AT-2030 portable calibration shaker table is designed for simple accelerometer and vibration transducer calibration without the need for advanced features. AT-2030 shaker table and vibration calibrator is a variable frequency, variable amplitude, battery operated portable shaker capable of calibrating accelerometers, transducers, and proximity probes. Applications are producing a known vibration signal in g’s, mils, or ips for sensor, wiring, instrumentation, and system checkout in vibration condition monitoring applications.
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, Type-N, 50 Ohm
85032F
-
The Keysight 85032F calibration kit contains precision 50 ohm type-N standards used to calibrate Keysight network analyzers. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 9 GHz.