Aggregator Taps
See Also: Test Access Points, Network Taps
-
Product
Multi-Protocol Wireless Application Networking System with Open, Integrated, Secure & Scalable System for Data Aggregation & Viewing
Ion
-
Jacobs’ vendor agnostic architecture was designed and implemented with the goal of an open Industrial Internet of Things (IoT) solution. ion© adapts and applies technology that enables our customers to gain efficiencies and savings, through connecting our client’s sites then collecting and displaying data in a unified interface. This provides custom insights to our clients, empowering them to ensure safety and respond quickly. The Jacobs ion© solution has been operationally deployed for over a decade and enables innovative approaches for data accuracy, data timeliness, and safety — greatly improving information flow and productivity.
-
Product
sbRIO-9213, Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
781210-01
Temperature Input Module
Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The sbRIO-9213 is a high-density thermocouple input module that is designed for higher-channel-count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The sbRIO-9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO-9213 features NIST-traceable calibration and a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
Product
Very High Density Fiber Tap
Flex Tap VHD
-
Keysight Network Applications and Security
Flex Tap VHD is a modular, very high density fiber tap available, offering up to 36 taps in a 19 inch 1U space, to reduce IT costs while helping ensure availability of security and business critical applications. Network taps (test access points) are a key part of the access layer of a visibility architecture because they are an unobtrusive way to capture monitoring data. They offer comprehensive traffic visibility for network monitoring and security tools that do not introduce points of failure in the network. Ixia has a large variety of network taps on the market today, offering speeds from 1Gbps to 100Gbps, single and multi-mode, as well as different fiber types and support for Cisco bidirectional (BiDi) transceivers.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Test Automation Platform (TAP)
-
The Keysight Test Automation Platform (TAP) provides powerful, flexible and extensible test sequence and test plan creation with additional capabilities that optimize your test software development and overall performance. TAP is a modern Microsoft .NET-based application that can be used stand-alone or in combination with higher level test executive software environments.
-
Product
HDLC RS-232 / RS-422 / RS-485 Passive Tap Module – USB Port
VERSA-TAP™
-
Versa-Tap protocol analyzer offers a powerful hardware solution that features state-of-the art electronics and provides exceptional data-logging/analyzer capabilities at a fraction of the cost of the nearest competitor.
-
Product
NI-9214, 16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module
781510-01
Temperature Input Module
16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module - The NI‑9214 is a high-density thermocouple input module that is designed for higher channel count systems. The NI‑9214 includes features to increase overall accuracy, such as CJC sensors in the terminal block, component layout to minimize thermal gradients, and an autozero channel for offset error compensation.
-
Product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-02
Temperature Input Module
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
TAP Detectors And Power Monitors
-
The “Premium” jumpers are VZ TPR Certified Cables that provide the highest level of reliability. We also offer the high performance “Standard” jumpers that are Telcordia GR 326 tested and certified. Both the Premium and Standard cables are made in our state of the art manufacturing facility recognized by leading global service providers as one of the best in the industry. We attribute our success to the highly dedicated and skilled production team which starts by selecting only the highest quality fiber and connector components.
-
Product
RS-232 Passive Tap Module
EZ-TAP™
-
Stratus Engineering’s EZ-Tap hardware module is a low-cost hardware bus analyzer and protocol analyzer solution that uses a traditional dual COM port approach to RS232 interface monitoring.
-
Product
NI-9217, 4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
779592-01
Temperature Input Module
4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9217 is a resistance temperature detector (RTD) input module. You can configure the NI‑9217 for two sample rate modes: high sample rate or high resolution. The NI‑9217 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9217 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Vacuum, Module, ITA, 90 Series, 2 Port Positions, w/ M22.5x1.5 Tap
510108251
ITA Module
Primary mating module 510104260. (May mate with other Receiver modules, as well.)
-
Product
NI-9210, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
784788-01
Temperature Input Module
4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The NI‑9210 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9210 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
Passive Tapping Solution
GPON Phantom™
-
GPON Phantom™ is a unique passive tapping device for Lawful Interception (LI) of optical fiber lines using GPON technology and deployed in a Fiber-to-the-x (FTTx) topology. The GPON Phantom records and stores broadband digital information, offering unique advantages for Law Enforcement Authorities (LEAs) looking to capture any data between the central office and the target, without being detected, while providing solid evidence with unique identification of the target.
-
Product
Free Data Monitoring Software For EZ-Tap™, EZ-Pro™, And Versa-Tap™ Passive Tap Modules
-
Stratus Engineering's EZ-View™ data monitoring program controls communication and data collection parameters and displays time-tagged communication data and handshaking events in an easy-to-use scrolling display window.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-02
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Complete TAP Signal Isolation for Corelis Boundary-Scan Controllers
ScanTAP IsoPod
-
The Corelis ScanTAP IsoPod™ is an add-on accessory that provides a galvanic isolation barrier between the target system and the boundary-scan (JTAG) controller hardware. While the Corelis boundary-scan controllers are highly robust and reliable, the complete electrical isolation helps prevent damage to the controller from harsh electrical environments where over-voltage and over-current can damage components.This Corelis ScanTAP IsoPod was designed to add an additional layer of protection with minimal cost and effort. Open the box and plug it in; everything just works.
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
785189-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Regeneration TAPs
-
Regeneration Fiber TAPs allow the tapping of fiber optic networks, while mitigating the power reduction of the optical signal that results from splitting.
-
Product
Bypass TAPs
-
Bypass TAPs provide fail-safe access for active in-line network security and performance tools. In the event that an active in-line tool becomes unavailable, either due to a hardware malfunction, power loss, software problem, or planned maintenance, bypass TAPs ensure the network link stays operational.
-
Product
sbRIO-9211, Non-Enclosed, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
780877-01
Temperature Input Module
Non-Enclosed, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The sbRIO‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
Product
4 TAP JTAG Boundary-scan Controller for Teradyne Systems
QuadTAP/CFM
Controller
The Corelis QuadTAP/CFM high-speed multi-TAP boundary-scan system makes advanced, multi-TAP boundary-scan testing within ICT systems a reality. By combining ICT and boundary-scan, test engineers gain benefits from both technologies for the highest possible test coverage, speed, and capability.Specifically designed for integration into Teradyne TestStation and GR228x testers, the QuadTAP/CFM and QuadTAP/CFM Expander enable a clean, convenient multi-TAP boundary-scan solution.
-
Product
Passive Network TAPs
ApconTap
-
Our portfolio of passive optical network TAPs captures network traffic under all conditions to simplify network monitoring and security. Each ApconTap model supports common datacenter optical fiber standards with split ratio options availble at 50/50, 60/40, and 70/30. With passive fiber 40G and 100G TAPs, APCON offers short-range, long-range, and bidirectional models to accomodate requirements for high-density, next-generation datacenter deployments.
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-02
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
On Load Tap Changer Analyzer
TAP-4-PLUS
-
The Tap-4-PLUS is the newest instrument by Zensol for OLTC testing. It has 2 more analog inputs than the TAP-4. The TAP-4-PLUS with the TAP-DRM accessory can perform dynamic resistance, vibration, and motor current recordings at the same time. Doing so will allow you to easily understand the vibration impacts.
-
Product
Taps And Passives
-
ATX offers the latest innovations in passives for HFC networks, including taps, couplers, splitters and power inserters. The 2GHz XS Series enables MSOs to support DOCSIS® 4.0 architectures, while the 1.2GHz SG Series will maintain a 1.2GHz plant and offers compatibility with Cisco’s popular Surge-Gap portfolio of hardline taps and passives. A bonus feature with the ATX 2GHz taps and passives is the upgradeable faceplate, futureproofing these HFC devices for 3GHz and beyond.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
785186-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-01
Temperature Input Module
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
Tapping Machine
STM-1
-
Tapping Machine Type STM-1 is intended for measurements of acoustic insulation of ceiling in buildings. The unit fulfils Annex A of ISO 140-6/7. These parts of the standard require a tapping machine as a sound source for impact noise measurements. Type STM-1 is available with an optional remote control.





























