Aggregator Taps
See Also: Test Access Points, Network Taps
-
product
Complete TAP Signal Isolation for Corelis Boundary-Scan Controllers
ScanTAP IsoPod
The Corelis ScanTAP IsoPod™ is an add-on accessory that provides a galvanic isolation barrier between the target system and the boundary-scan (JTAG) controller hardware. While the Corelis boundary-scan controllers are highly robust and reliable, the complete electrical isolation helps prevent damage to the controller from harsh electrical environments where over-voltage and over-current can damage components.This Corelis ScanTAP IsoPod was designed to add an additional layer of protection with minimal cost and effort. Open the box and plug it in; everything just works.
-
product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-01
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
product
4 TAP JTAG Boundary-scan Controller for Teradyne Systems
QuadTAP/CFM
The Corelis QuadTAP/CFM high-speed multi-TAP boundary-scan system makes advanced, multi-TAP boundary-scan testing within ICT systems a reality. By combining ICT and boundary-scan, test engineers gain benefits from both technologies for the highest possible test coverage, speed, and capability.Specifically designed for integration into Teradyne TestStation and GR228x testers, the QuadTAP/CFM and QuadTAP/CFM Expander enable a clean, convenient multi-TAP boundary-scan solution.
-
product
Filtering Network TAPs
Filtering network TAPs allow you to filter out the packets and traffic that is not needed by the tool to perform its function. Filtering ensures that monitoring ports do not become oversubscribed with unneeded data. Filtering TAPs are purpose-built hardware devices that let you see every bit, byte and packet.®
-
product
sbRIO-9213, Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
781210-01
Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The sbRIO-9213 is a high-density thermocouple input module that is designed for higher-channel-count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The sbRIO-9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO-9213 features NIST-traceable calibration and a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
product
Bypass Network TAPs
Bypass TAPs (bypass switches) are used to connect a monitored network segment to an active, in-line security device and monitor the device's health. If your security tool goes off-line, the bypass TAP automatically 'switches to bypass mode' keeping your network link up while you resolve the issue. Garland's Bypass TAPs with failsafe technology guarantee 100% network up-time and let your security devices see every bit, byte, and packet.®
-
product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-01
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Standard Tap Position Indicator
NMC,s Tap Position Indicator is a Microprocessor based specially designed instrument used to indicate the Tap Position of the Power Transformer with On Load Tap Changer.
-
product
NI-9210, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
784788-01
4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The NI‑9210 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9210 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.