Product
Circuit Breaker Test System
TDR900
-
It operates and records a circuit breaker’s contact timing, motion, velocity, main contact engagement & synchronization, trip and close coil initiation and currents.
-
Product
Air Circuit Breakers
-
Mitsubishi Electric Automation, Inc
Low-voltage air circuit breakers (ACB) can be used as the main circuit breakers of power distribution systems in buildings, factories and ships. The AE-SW series offers a "fixed" type or "drawout" type option. This ACB series ranges from 630 amps to 6300 amps and provides high-level circuit monitoring as well as friendly networking capablities for a wide range of applications.
-
Product
Dynamic Micro Ohm Meter
PRIME 600
-
It is the only micro ohm meter in the market that integrates both the contact resistance and the dynamic resistance measurement (DRM) for cost-efficient condition evaluation of contacts in SF6 and vacuum type circuit breakers; PRIME is a high current micro-ohmmeter that provides true pure DC with smart control up to 600 A, a wide measurement range with high power, dual ground testing process, thermal printer, touch display, pre-defined test modes and automatic reporting.
-
Product
Automatic Circuit Breaker Timer Kit With Printer
-
NMC OFFERS FULLY AUTOMATIC CIRCUIT BREAKER TIMER KIT WITH IN BUILT PRINTER AND COMPUTER INTERFACE.
-
Product
Switchgear Testing Solutions
-
IES Systems is a world leader in the design and manufacturing of power switchgear test systems.*GFCI/AFCI Circuit Breaker Test Solutions*Medium Voltage Breaker Test Solutions*Residential Circuit Breaker Test Solutions*Molded Case Circuit Breaker Test Solutions*AIR Circuit Breaker Test Solutions*Vacuum Bottle Test Solutions
-
Product
Digital Circuit Breaker Analyzer
CT-3500 S2
-
The CT-3500 S2 is Vanguard’s second generation, stand-alone, digital, microprocessor-controlled, circuit-breaker timer. It measures the elapsed time from the instant a breaker coil is energized to the instant of opening or closing of a circuit-breaker’s dry contacts. In addition to timing a breaker’s contact response time, the CT-3500 S2 can also time relays or other switching functions that use an initiating trigger voltage (24-300 Volts DC or AC). The timer-triggering voltage starts three independent electronic timers. Each timer is individually stopped by its respective dry-contact closing or opening. The CT-3500 can fully analyze the timing of all circuit breaker operations (Open, Close, Open – Close, and Close – Open). Timing results are displayed in milli-seconds and cycles on the unit’s back-lit LCD screen and can be printed on the built-in 2.5-inch wide thermal printer.
-
Product
Stationary Circuit Breaker Test System
ACTAS C160
-
Stationary test system for carrying out fully automatic final factory tests, type and function tests on all kinds of switchgear devices, such as circuit breakers, disconnectors or earthing switches, regardless of the type of drive unit. All the electrical and mechanical parameters needed for the assessment of switching performance are measured in real time and evaluated without either the main contact chambers or the drive unit having to be opened. The system has analog and incremental input channels for the acquisition of analog quantities.
-
Product
Corona Discharge Checker
MK-720
-
MK-720 enables finding of insulation deterioration on insulators, disconnectors, and circuit breakers, at hot-line condition!
-
Product
Primary Test Manager
-
The Primary Test Manager™ (PTM) software supports you during diagnostic testing, condition assessment and data management of medium- and high-voltage assets, such as circuit breakers, rotating machines, grounding systems, instrument and power transformers as well as bushings and on-load tap changers (OLTC).
-
Product
Relay Test Set
RNT-5A
-
This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc. The set is designed for both laboratory and field use.
-
Product
Circuit Breakers for Panelboard and Controlboard
-
Mitsubishi Electric Automation, Inc
Series of MCCB and ELCB that provide maximum protection in a small frame size. A complete product offering for equipment control cabinets and distribution panels.
-
Product
Electric Shock Protection Analysis
-
60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel
-
Product
Circuit Breaker Test Equipment
-
DV Power has released a new generation of circuit breaker test equipment for condition assessment of medium and high voltage circuit breakers.Field-portable instruments with standalone or PC controlled functionality, allow performing various tests during circuit breaker manufacturing, commissioning and maintenance stages.Applications supported by the DV Power test equipment include measurements of:Contact resistanceDRM (dynamic resistance measurement)Coil resistance and coil current (IEC 62271-100)Mechanism charging time (IEC 62271-100)Minimum trip voltage (IEC 56, ANSI C37.09)Undervoltage release (IEC 60694)The timing of a circuit breaker’s main, auxiliary and pre-insertion contactsSynchronization between the contactsMotion and velocity“First trip” testThe essential part of a circuit breaker condition assessment is the ability to compare the latest test results with the previous testing. Accordingly, our instruments store measured values and compare them to a manufacturer’s limits. Also, a fingerprint obtained in this way can be used at a later stage as a reference during subsequent measurements. In order to obtain an accurate comparison, the tests need to be performed using identical test parameters. Consequently, any deviation and change in the test results may indicate the circuit breaker condition deterioration. Even more, to overcome this issue, DV-Win enables test plans and graph overlay features.Finally, as a final result of a circuit breaker maintenance process, the DV-Win provides analytical tools and customized report creations.
-
Product
Circuit Breaker Analyzer
CBAnalyzer
-
Simple operation requiring minimal trainingVery portable - it's a laptop or tablet pc running our Windows software programNo modification of the circuit breaker is requiredNo electrical connections are requiredRemoval of the circuit breaker from its mounting or cubicle is not requiredTesting can be performed during routine switchingData is easily transmitted over the internet to the users account where it is analyzed and compared with a known good profile (KGP) for that type of circuit breaker to determine: • Overall mechanical condition • Confirm maintenance intervals and lubrication • First trip testing data for arc flash compliance • Arc flash study validation checksPerform detailed analysis and store maintenance records using CBAnalyzer suite softwareAccess to the CBAnalyzer Account Manager which: • is where user accounts are created and each user's role is designated • provides access to your equipment database and test data archives • is where tests are synced • is where your equipment data is entered and stored • is required to use the CBAnalyzer software program
-
Product
Analyzers and Timers
CAT Advanced Series
-
Description The Advanced CAT Series Analyzers and Timers are stand-alone or PC-controlled digital instruments for circuit breaker status evaluation. Timing channels record arc closing and opening, resistance and auxiliary contacts. The main contact channels can also measure the resistance value of pre-insertion resistors (if present in the breaker). The advanced CAT series records graphs of the opening and closing coil currents and the movements of the moving parts of the high and medium voltage circuit breaker. Test results are printed on the 112 mm (4.4 inch) thermal printer (optional accessory) in tabular and graphical form. The advanced CAT series provides easy selection of different operating modes:
-
Product
3-Phase AC Voltage Transducer
ENVIROMUX-PT3-600
-
Monitors and reports voltage of any 3 phase circuit. Remotely detect blown fuses or tripped circuit breakers. Three 600 VAC inputs, three 4-20 mA outputs. Inputs and outputs isolated from one another. Frequency: 50/60Hz. Maximum primary current: 600 volts. Accuracy: ±0.25% F.S. @60Hz. Output: 4-20 mA. "Zero" adjustment for accurate 0 VAC reading, and "Calibration" adjustment for frequency and voltage level. Powered by the ENVIROMUX-S420MA-24V. Regulatory approvals: UL, CUL, CE. Requires two ENVIROMUX-S420MA-24V to monitor three phases. Caution: installation should be performed by qualified electricians only. Make sure electrical service is disconnected before making any electrical connections.
-
Product
PC Based High Current Test Set for Circuit Breakers and Temperature Rise Test Equipment
-
This equipment comprises of high current source for testing of circuit breakers with additional facility for temperature rise testing (thus incorporating testing for moulded case, vacuum & air circuit breakers as per IEC 60947-2). The system integrates a servo controlled source with closed loop current feedback to maintain the current constant. It has the necessary instrumentation for maintaining current at full load & other conditions arising in testing at high current. The bench has a PC based control system with temperature data logger (24 channel with ch-ch isolation amplifiers). The data logger displays as well as stores a set of temperature values with time.
-
Product
24 V DC Power Supplies
-
*Space-saving design*High power reserves*Low heating of the control cabinet*Low inrush current*Safe switch-off by circuit breakers in case of short circuit
-
Product
Measuring Device for Testing the Effectiveness of Residual Current Protective Devices (RCD) According to DIN EN 61557-6 (VDE 0413-6)
-
PeakTech Prüf- und Messtechnik GmbH
A residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE).
-
Product
Circuit Breaker Analyzers & Timers
CAT Advanced Series
-
DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.
-
Product
Voltage Tester
-
PeakTech Prüf- und Messtechnik GmbH
Uses voltage detection technology for the detection of voltage in cables, cords, circuit breakers, lighting fixtures, switches, outlets and wires.
-
Product
Circuit Breaker Test Systems
-
Crest has over a decade of experience of designing and manufacturing test systems for testing all the different kinds of switchgear and controlgear.
-
Product
Contacts Resistance Tester
JYK II
-
•Instrument IPC architecture for domestic production of all models of metal contacts SF6 switchgear, GIS combination of electrical, vacuum switch, oil switch and column switches, contacts and so on.•Sensor: Acceleration speed sensor, rotation speed sensor, linear stroke sensorinstallation is very easy and simple.•Trigger: The trigger, external trigger, the sensor is triggered. Sensor can trigger the circuit breaker manually switching characteristic test, such as a manual column pole division switch.
-
Product
DC Hipot Test Set
KVZG
-
KV Hipot Power Test Equipment Co.,Ltd
DC Hipot Tester is applied to measure output voltage and leakage current for zinc oxide arresters, magnetic blowing arresters, power cables, generators, transformers, circuit breakers and other equipment.
-
Product
Micro-Ohmmeters
RMO-G Series
-
The RMO-G is a portable micro-ohmmeter designed for contact resistance measurement of non-inductive test objects and applications with increased safety requirement. It tests medium and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links. Due to its Both Sides Grounded and Remote Control functionalities, the instrument accurately measures even in the most demanding environments, providing additional safety to testing personnel.The RMO800G is the most powerful portable micro-ohmmeter on the market with 800 A output current. RMO200G is our best seller in the USA. A user can choose the appropriate model depending on the output current requirement, from 100 A (RMO100G) to 800 A (RMO800G).We use an unbreakable plastic case with IP67 protective rating (with closed lid) for instruments’ housing. Although very portable and lightweight, RMO-G micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents. Consequently, it enables the usage of thinner/longer test cables. RMO-G generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. During the testing, it increases current before measuring and decreases current after the measurement. This significantly decreases magnetic transients and ensures great accuracy.Special current clamps measure a current through groundings when the instrument tests in Both Sides Grounded conditions. The instrument itself powers these clamps. If even higher safety level is required, the Remote Control feature enables the operator to perform measurements from distant locations.RMO-G instruments can store up to 500 measurements in internal memory. Also, they have a built-in thermal printer and USB flash drive available as an option. An additional option is the built-in High Precision module suitable for measurement of very low resistance, in the range from 1 to 30 µΩ, with 0,01 µΩ resolution.Our free DV Win software communicates with the RMO-G micro-ohmmeters via USB or RS232 interface. It allows a user to run the test remotely from a PC. Also, a user can download test results, analyze and generate fully configurable test reports through the software.
-
Product
External Load Module
ELM
-
Circuit breakers are often overlooked during maintenance of electrical systems in aircraft, or often only verified for open and closed states. To test the true functional purpose of a circuit breaker it requires the application of current in excess of the rated trip value and then measure the time for the breaker to actually trip. This is the only way to verify that a circuit breaker will react as designed if an electrical failure occurs.
-
Product
Volt-Finger Detector / Driver
LVD-18
-
Standard Electric Works Co., Ltd
● Bright LED and audible alarm sound when voltage is present.● Designed for both contact and non-contact voltage detection.● Direct contact voltage detection: 50V~600Vac.● Non-contact voltage detection: 50V~600Vac.● Can be used to detect voltage in lighting fixtures, circuit breakers.● Compact and handy.● Can be used to find a break in a wire.● Continuity test and basic driver function..● Flashlight.
-
Product
SF6 Optical Gas Imaging Camera
FLIR GF306
-
The FLIR GF306 optical gas imaging camera visualizes sulfur hexafluoride (SF6) and other gas emissions without the need to shut down operations. SF6 is used in the electric power industry as an insulator and quenching medium for gas-insulated substations and circuit breakers. The portable, non-contact GF306 allows you to quickly scan substations for leaks while maintaining a safe distance from high-voltage equipment. By catching leaks early, the GF306 reduces lost revenue to breakdowns and repairs.
-
Product
Turn-Key Short Circuit Laboratories
-
For low and medium voltage switchgear including :*Circuit breakers*Contactors*Disconnect switches*Fuses*Miniature circuit breakersApplied tests for low and medium voltage switchgear :*Dielectric withstand test*Impulse withstand test*Breaking capacity test*Mechanical life testElectrical life test*Over load performance test*Short circuit breaking capacity test**Short time short circuit impulse current test*Temperature rise test*Operation performance testTests for low & medium voltage panels :*Short time short circuit impulse current test*Dielectric test*Impulse withstand voltage test*Temperature rise test
-
Product
HV DC Test Set
RX30/4P
-
K&S Engineering and Scientific Ltd
The output is continuously variable from zero to 10 kV by means of the panel mounted regulator. An output trip is fitted which operates when the output exceeds 25 mA switches off the test set and operates a neon overload indicator. Primary protection is provided by two panel mounted fuses. The output is protected by the output trip and a magnetic/hydraulic circuit breaker.