Thermocouple Loggers
Data Acquisition from thermocouples and data record of termperature events.
See Also: Temperature Loggers
-
Product
Multi-Channel Programmable and Universal Input Data Loggers
-
These dataloggers have multiple channel inputs which can be universally configured to record temperature, process voltage/current, pulse, strain, etc.
-
Product
AC Event Data Loggers
-
The Track-It™ AC Event Data Logger is a battery powered stand alone compact data logger that records up to 64,000 on/off cycles. Use the Track-It™ AC Event Data Logger to monitor cycle patterns of pumps, blowers and other electrical equipment powered by 120 or 240Vac.
-
Product
Wireless Data Logger System
HD35
-
Wireless datalogging system allowing the monitoring of a multiplicity of physical quantities in the most diverse fields of application. Temperature - Humidity - Atmospheric and differential pressure - Illuminance - Irradiance UVA, UVB, UVC, CO, CO2 - Solar radiation - Precipitation - Wind speed and direction, Leaf wetness, Volumetric soil water content, Level, WBGT.
-
Product
Clear Room Logger Transmitter
HD50CR
-
The HD50CR is the ideal solution for monitoring of differential pressure, temperature and humidity in Clean Room applications.
-
Product
Thermocouple Switchbox
SWT-2
-
The SWT-2 is a compact, economical switchbox that lets you use two probes in a thermometer which has a single input. SWT-2 was designed with our BAT-12 Thermometer in mind - it is small and easy to carry in the field with a portable BAT-12 - but it also fits any miniature Type T socket. A subminiature connector mates quickly and easily to most Type T thermometers.
-
Product
Basic Quad K-Type Analog Thermocouple Amplifier
SEN-30103-K0
-
Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.
-
Product
Pressure Micromanometer – Thermometer Data Logger
HD2114.2
-
Handheld micromanometer - thermometer data logger with 20mbar built-in sensor
-
Product
MAX31856 Thermocouple Sensor Arduino Shield
SEN-30007-J
-
Quad channel thermocouple Arduino shield based on the MAX31856 universal digital thermocouple interface IC. This is an exciting update of the MAX31855, with improvements in resolution (19 vs 14 bits), on-board temperature reference (6 vs 4 bits), and compensation (fully compensated vs nonlinear correction required). The MAX31856 is interfaced via 4-wire SPI with options for interrupt triggering. An LDO and a high-speed level shifter are included on ALL device pins to allow interfacing with to any Arduino - both 3.3V and 5.0V variants - without sacrificing device performance in any operating condition.
-
Product
Nitrate Logger Sensor
NUL-241
-
The NeuLog nitrate sensor can be used to measure the concentration of nitrate ions (NO3-) in aqueous samples.Nitrates are used in fertilizers and can contaminate water. Also, untreated human sewage can be a source of nitrate contamination.Nitrate measurements can also be very relevant to study the nitrogen cycle in general and to relate this cycle to plants and algae.
-
Product
Mini Logger
OBD
-
The DAWN OBD Mini Logger™ is a compact, low-cost data logger to acquire CAN bus data from cars and trucks. The logger installation is simple since it snaps directly on the J1962 OBD connector. The logger is so small that it fits in the palm of your hand.
-
Product
Data Logger w/ MiLAB Software
NOVA 8
-
Included with the NOVA 8 is the new, full version MiLAB data analysis application, which is based on Fourier’s award-winning MultiLab software. MiLAB features an intuitive and user-friendly interface that makes it easy for students to collect, interpret and understand data collected. Other features include: data collection from up to 8 sensors simultaneously, sampling rates of 100,000 samples per second, Wi-Fi & Bluetooth connectivity, as well as teacher-friendly projector connectivity.
-
Product
CO2 Logger Sensor
NUL-220
-
This logger sensor is based on an electromechanical reaction between CO2 gas and the sensor. The result of the electromechanical reaction is voltage, measured by the logger sensor. The measure units are ppm (parts of CO2 per million of air).
-
Product
Gauge Type T Thermocouple Wire
W-TW-44P
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Compensation Block for Thermocouple Simulator Modules
40-965-912
Isothermal Termination Block
The Compensation Block is a accessory specifically designed for the 41-760 and 41-761 Millivolt Thermocouple Simulator modules. This block will give the user the temperature of the front panel junction of the module to cabling. This data can then be combined with other factors, temperature on the other end of the cable for example, to compensate the thermocouple hence increase the accuracy.
-
Product
Logger version 2-D electro-magnetic current meter
INFINITY-EM AEM-USB
-
Infinity EM is an autonomously deployable EM (electro-magnetic) current meter with a data logger. Due to the principle, the instrument provides high accurate 2-D current measurements in even low scatter fields, where ADVs (Acoustic Doppler Velocimeter) has difficulties. The measurement range is wide from 0 to ± 500 cm s-1. The instrument design is compact (1.0kg in air). Infinity EM allows for current velocity measurements virtually anywhere.
-
Product
Dew Point Logger Sensor
NUL-245
-
This sensor measures temperature and humidity in a volume and gives the temperature below which the water vapor in that volume of air (at a constant barometric pressure) condenses into liquid water (the dew point).
-
Product
Midi Logger`
GL980
-
*8CHHigh speed simultaneous sampling*Includes 500 V measurement with 16-bit A/D converter*Equipped with true-rms measurement*Large built-in RAM (4 M sampling/ch) and built-in Flash memory (4 GB)*Large easy-to-read 7-inch LCD
-
Product
Midi Logger
GL840 Series
-
Modules allow wide range of measurements. Suitable for a variety of measurements due to flexible combinations
-
Product
PXI Millivolt Thermocouple Simulators
Series 41-760
Simulator
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channelseach channel providing a low-voltage output across two connector pins capable of providing 20mV with 0.7V resolution, 50mV with 1.7V resolution and 100mV with 3.3V resolution, covering most thermocouple types. These thermocouple simulators use two wire outputs with a remote output reference sense to ensure the modules deliver accurate low-level voltages, even if the system has common mode voltages present. In addition, each simulation channel is also able to provide an open circuit setting to simulate faulty wiring connections to a sensor.
-
Product
K Thermocouple Surface Probe
TP647
-
Surface thermocouple Type “K” probe. Fiberglass cable. Tolerance according to IEC 60584-2 standard.
-
Product
Data Logger Centesimal Thermometer Pt100
HD2107.2
-
Centesimal thermometer in the range ±199.99 °C, decimal outside this range, one input for Pt100 probes with SICRAM module, measuring range -200 °C…+650 °C.
-
Product
The Field Logger
-
The Field Logger is a stand-alone data logger which is capable of recording potential vs. time and LPR vs. time data. The instrument is battery powered and records data onto an attached SD memory card. The instrument is entirely contained within a waterproof (IP67), tough polycarbonate enclosure (23x19x11cm), with probe connection via a single high quality watertight Lemo or Amphenol connector.
-
Product
Environmental Weather Station / Data Logger
-
Pratt & Whitney Measurement Systems, Inc.
Customizable Display – display any combination of the following outputs
-
Product
Two Inputs Thermocouple Thermometer
HD2328.0
-
Thermocouple thermometer for probes type K, J, T, E. It measures temperature by means of immersion, penetration, contact or aria probes. Two inputs for miniature thermocouple connectors. Storage of maximum, minimum, average value. Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree.
-
Product
Voltage Data Logger Single Channel
VA601-V262
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Multifunction data logger with K J PT type current .voltage : K.J . PT100. PT1000. mADC. AAC. VDC.VAC.
-
Product
Data Loggers
-
Watlow Electric Manufacturing Company
Watlow offers a range of products for time-stamped data collection of critical process data, from Windows®-based software to embedded data loggers. Data loggers reduce labor, increase accuracy and help companies comply with regulatory requirements by automating data collection. These products make it easy to add data acquisition to existing processes, make data available to analytical software in spreadsheet compatible files, allow data to be grouped in user-defined batches and incorporate operator comments and other information into reports. Software solutions record data directly on a computer and data from embedded data loggers is transferred to a computer via universal serial bus (USB), secure digital (SD) card or flash drive.
-
Product
Temperature Logger for PT1000 Probe
TV-4204
-
PT1000 probes are available with this logger and will record down to -200C making them suitable for cryogenic applications. The probes are of 3-wire construction and available probes are listed in the 'You will also need' section.
-
Product
Basic Quad K-Type Analog Thermocouple Amplifier
SEN-30103-K1
-
Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.
-
Product
Loggers
-
The logger sends in real time its measures to the PC. If a measure is not received by the PC, it stores it inside its internal memory and sends it to the PC on the next communication channel.
-
Product
Temperature Logger
TGU-4020
-
This unit uses an external probe (not included) to record temperature in awkward to reach areas or applications where a fast response is required. It can also measure higher temperatures than the self-contained unit. The tip of the probe can be exposed to temperatures up to 125C.





























