Optical Tunable Filters
-
Product
Optical Components
-
Digital Signal Technology, Inc.
Digital phase detector, sweeper, driver
-
Product
Tunable Laser Hydrogen Chloride Analyzer
TX-100
-
Laser HCl analyzer with a probe type optical system which employs direct insert method. TX-100 is suitable for monitoring HCl concentration in incineration plants and the control of HCl removal process in various industries including cement factories and petrochemical plants, etc.
-
Product
Gas Filter Correlation CO Analyzer
Model T300U
-
Teledyne Advanced Pollution Instrumentation
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF120
-
Lifasa - International Capacitors, SA
Accessories: Differential protection
-
Product
R.F. Coupler and high Pass Filter
7415-3
-
There are those who disagree with the r.f. conducted susceptibility test setup of Method CS02 of MIL-STD-462. Homemade rigs have sprouted to comply with the coupling capacitor requirement, each with it own disadvantage. Our little Type 7415-3 R.F. Coupler is the answer. A neat little box with BNC connectors and a pair of binding posts, it is rated at 270 V.A.C. at the LINE terminals and 20 volts PMS into the GEN port. Looks good and does a fine job.
-
Product
Broadcast Filters UHF
-
RFS Waveguide UHF filters are now 4th generation products designed for global combining and filtering applications associated with DTV and analog television transmissions.
-
Product
Optic Node
OX 752
-
Converts even weak Optic Signals to a high quality RF Signal. LED BAR Optic Level Display has been provided for ease of system maintenance. They are best suitable for Analog as well as Digital transmission to maintain BER, MER Characteristics.- High Quality Nodes- Frequency 40 ~ 1000 MHz- Good Sensitivity of -11 dBm- RF O/P 110 dBµV at 0 dBm Optic I/P- High Voltage Surge Protection- LED Optic Level Display- Powder Coated Housing
-
Product
Three-State Kalman Filter Algorithm
A6-1PPS
-
The A6-1PPS uses a three-state Kalman filter algorithm to measure and correct the frequency offset of the oscillator with respect to the 1pps input.
-
Product
Narrow Band Filters (Single Octave)
POWER-POLE® Series
-
The POWER-POLE® Series of tunable filters provides improved RF performance with increased power handling capability and the lowest insertion loss for a given bandwidth. The product line includes several standard designs in various frequencies to support almost any application. Approximate performance is summarized in the POWER-POLE Series Selection Guide.
-
Product
Optical OTDR
TLM-02D
-
Hangzhou Tuolima Network Technologies Co., Ltd.
OTDR-02D series Optical Time Domain Reflectometer (OTDR) is an intelligent meter of a new generation for the detection of fiber communications systems. With the popularization of optical network construction in cities and countrysides, the measurement of optical network becomes short and disperse; OTDR-02D is specially designed for that kind of application. It’s economic, having outstanding performance.
-
Product
Optical Detector
LG-9200
-
The LG-9200 is a non-contact type optical detector which emits red visible light and detects the reflected light from the rotating shaft. The reflection mark is used for the detection by affixing it on the rotating shaft. It enables detection at an angle. (reflective mark: HT-011 by Ono Sokki)The LG-9200 has a built-in compact amplifier and outputs the square wave (voltage) after waveform shaping.With a compact and light weight body, performances are upgraded compared to the previous model LG-916.(LG-9200 detection distance: up to 40 mm, response speed: up to 40 m/s)
-
Product
Mid-Range Gas Filter Correlation CO Analyzer
Model N300M
-
Teledyne Advanced Pollution Instrumentation
The Model N300M is a microprocessor-controlled analyzer used to determine the concentration of carbon monoxide (CO) in a sample gas. The analysis method is based on the Beer-Lambert law.The N300M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
Product
Optical Profiler
DRK8090
-
Shandong Drick Instruments Co., Ltd.
This instrument uses noncontact, optical phase shift interferometry method does not damage the surface when measuring graphics can be quickly measured by a variety of three dimensional surface morphology, and analyzed to calculate the measurement results. Suitable for measuring a variety of blocks, the surface roughness of optical components; scale, dial the groove depth; magnetic (optical) disk, the head surface texture measurements; structural morphology of coating thickness and coating trough structure at the boundary of the grating; silicon surface roughness measurement and the graph structure and so on.
-
Product
Tunable Diode Laser Absorption Spectroscopy
5100P TDLAS Transportable
-
Using tunable diode laser absorption spectroscopy, the 5100P is a transportable, easy-to-use analyzer optimized to measure either water vapor (H2O) or carbon dioxide (CO2) in select gas streams.
-
Product
Gas Filter Correlation CO2 Analyzer
Model N360
-
Teledyne Advanced Pollution Instrumentation
The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
Product
Automated Filter Tester
8130A
-
The Automated Filter Tester Model 8130A continues to be the best solution for testing particulate respirator filters, disposable filtering face pieces, and a wide assortment of filter media. The TSI filter testers have been used in quality control and manufacturing by leading filter and filter media manufacturers and test centers around the world for more than 20 years.
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF1200
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralizedcompensation of power factor in low voltage instalations
-
Product
Gas Filter Correlation Carbon Dioxide Analyzer
Model T360
-
The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Optical Slits
-
The APPLIED IMAGE Optical Slit reticles are available in sizes from 10μm (0.01mm) to 1,000μm (1.0mm) widths, on either Chrome on Glass or Chrome on Opal material, with an overall size of 25.4mm (1.0 inch) diameter.
-
Product
8-Channel Amplifier and Low-Pass Filter Module
SCS-819
-
The SCS-818 and SCS-819 amplifier/filter module provides eight 4-pole low-pass filters that can be individually configured for a cutoff-frequency from 0.5Hz to 70kHz(SCS-818) and 0.5Hz to 70kHz(SCS-819). Each of the SCS-818/SCS-819's eight channels features an instrumentation amplifier with software-selectable gains of 1 to 1000 in 1-2-5 steps.
-
Product
Optical Tensiometers
Theta High Pressure
-
The Attension® Theta High Pressure is a tensiometer for measuring wettability and interfacial tension at high pressures and high temperatures within enhanced oil recovery research. With the harsh conditions of an oil reservoir in mind, the instrument is designed to ensure ease of use and yet offer wide measurement possibilities.
-
Product
Optical Testing
-
We place a great emphasis on our ability to test everything we produce and supply. This has provided the impetus for us to design and build comprehensive testing facilities that include standard as well as custom-made testing equipment.
-
Product
9 kHz Highpass Filter
TBHPF1-9KHZ
-
9 kHz Highpass Filter for protection of spectrum analyzer or EMI-receiver RF inputs against high amplitude subharmonics and residual 50 Hz voltage in conducted emission measurement set ups
-
Product
AC Power Line EMI Filters
CleanSweep®
-
CleanSweep® filters block EMI on power lines (both common and differential modes) and, uniquely, in ground, from reaching sensitive equipment. They also reduce EMI "backflow" from a "noisy" source that otherwise would end up on your AC power network.
-
Product
Programmable, 2-Channel High-Pass Filter Module
AAF-HP
-
The AAF-HP series provides 2 programmable channels of high-pass filtering on a plug-in module that is pin compatible with the popular AAF-1F, AAF-2F, and AAF-3F modules.
-
Product
Wide Band Filters (multi-octave)
NANO-ERF® Series
-
The NANO-POLE® Extended Range Series of tunable filters was developed to address applications needing an extremely small surface-mount package with low power consumption. Wide tuning range is accomplished with careful design to minimize size and power consumption.
-
Product
Power Capacitors with Protection Filter
CPFVF / CPMVF
-
Lifasa - International Capacitors, SA
The capacitors of the CPFVF and CPMVF series are formed by a power capacitor, an antiarmonic protection reactance and fuse or magnetothermic protection. These capacitors are specially designed for the fixed compensation of transformers in networks with a high level of harmonics.
-
Product
Optics Test Systems
IR Autocollimator
-
Optik Elektronik Gerätetechnik GmbH
The infrared autocollimator was specially designed for the 1550 nm wavelength range. In conjunction with the CROSDETECT evaluation software, it achieves a measuring accuracy of 1 arcsec with a resolution of 0.1 arcsec. The camera used is suitable for the wavelength range from 900 nm to 1700 nm.
-
Product
dv/dt Filters
-