Filter Results By:
Products
Applications
Manufacturers
High Voltage Probes
handle voltages beyond general purpose passive probes and operate in the range >500 volts and <20,000 volts.
See Also: High Voltage Meters
-
product
Replacement Spade Terminals for High Voltage Differential Probe
PK-HVA-05
Replacement Spade Terminals for High Voltage Differential Probe
-
product
Insulation Resistance Tester For PV (Judge Deterioration Point)
MIS-PVS
MULTI MEASURING INSTRUMENTS Co., Ltd.
The model MIS-PVS is an insulation resistance tester for the exclusive use in photovoltaic systems. The ordinary insulation resistance testers cannot make measurement properly during generation of PV systems. This instrument, however, can measure the insulation resistance simply by touching probe to the live line whether making generation or not. There are two ranges of PVH and PVL. PVH is for high voltage generation system (more than 500V and less than 1000V) and PVL is for the system less than 500V.
-
product
Logic Analyzers
Verification and debug of today's high speed, low voltage digital signals requires probing solutions that can accurately acquire from a wide variety of electronic designs and protect signal fidelity. Tektronix logic analyzer probes contain a variety of connectivity options that are engineered to ensure that signal acquisition is a true reflection of your design's performance. Compare and learn more about Tektronix logic analyzer probe solutions.
-
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
High Voltage Probe
HVP-15HF
*MAX.VOLTAGE:15KV DC.*BANDWIDTH:DC~50MHz.*DIVISION RATIO:X1000.*SIGNAL/NOISE:>60dB(1KHz)
-
product
Attenuation 1000 High Voltage Passive Probe
* high voltage multimeter probe is a 1000:1 fixed attenuation ratio passive probe. This probe is designed to test high voltages for multimeters. With high voltage and high precision.* The test signal can be read on the multimeter, and the multimeter multiplied by 1000 is the actual test result.* High reliability and high security.* The highest voltage can measure DC up to 30KV.
-
product
DC-to-250MHz 1:100 Oscilloscope Probe Kit (HP-9258)
PRB-HP-9258
The Oscilloscope Probe 1:100 - HP-9258 is a low-input capacitance high voltage 1:100 oscilloscope probe with a bandwidth of 250 MHz designed and calibrated for use on scopes having an input impedance of 1 MOhm shunted by 20 pF. However, it may be compensated for use with oscilloscopes having an input capacitance of 10 - 35 pF.
-
product
6kV High Voltage Passive Probe, 500 MHz
PPE6KV-A
High voltage single-ended passive probes are suitable for a wide range of applications where ground-referenced high-voltage measurements must be made safely and accurately. There is also a sense pin to automatically configure the oscilloscope for use with the probe.
-
product
Insulation Resistance Tester for PV (2 range)
MIS-PV1
MULTI MEASURING INSTRUMENTS Co., Ltd.
The model MIS-PV1 is an insulation resistance tester for the exclusive use in photovoltaic systems. The ordinary insulation resistance testers cannot make measurement properly during generation of PV systems. This instrument, however, can measure the insulation resistance simply by touching probe to the live line whether making generation or not. There are two ranges of PVH and PVL. PVH is for high voltage generation system (more than 500V and less than 1000V) and PVL is for the system less than 500V.
-
product
High Voltage Differential Probes
DP Series
Shenzhen Micsig Instruments Co., Ltd.
*Micsig DP Series High Voltage Differential Probes can be used with any brand of oscilloscope. *It adopts high-impedance isolation between the input and output to protect personal safety, converts the input high-voltage signal to a low-voltage signal for observation and analysis on oscilloscope.
-
product
1.5kV, 200 MHz, 2 pF, 10 M, Rise Time < 1.75 ns, High Voltage Differential Probe
T3HVD1500-200
1.5kV, 200 MHz, 2 pF, 10 M, Rise Time < 1.75 ns, High Voltage Differential Probe.
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP024-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Power/Voltage Rail Probe. 4 GHz Bandwidth, 1.2x Attenuation, +/-30V Offset, +/-800mV
RP4030
The Teledyne LeCroy RP4030 Power Rail Probe meets the specific requirements of those who need to acquire a low-voltage DC signal as part of a:-Comprehensive power integrity, digital power management IC (PMIC), voltage regulator module (VMR), point-of-load (POL) switching regulator, or low-dropout regulator testing- Complete embedded power management system that includes PMICs, VRMs, POLs, and LDOsThe RP4030 will faithfully acquire a low-impedance, low-voltage DC power/voltage rail signal without unduly loading the device under test (DUT), while providing high offset to allow DC power/voltage rail signal display on an oscilloscope with high gain.
-
product
Field thermal needle system for thermal resistivity / conductivity measurement
FTN01
Hukseflux Thermal Sensors B.V.
The FTN01 Field Thermal Needle System allows performing fast, on-site measurements of the thermal resistivity or conductivity of soils, in particular around the typical depth of burial of high voltage cables. FTN01 is designed with a focus on robustness and saving time, while still offering sufficient accuracy for typical field measurements. The sensor is a Non-Steady-State Probe (NSSP), TP09, which is mounted at the tip of the Lance LN01. The system is operated using a hand-held Control and Readout Unit CRU01.
-
product
Hi-Z Probes
B-1012-B
High Voltage Probes for Very Low Current Power Supply Voltage Measurementto 120kV, such as Electrostatic Paint Spray Applications...
-
product
Injection Transformer
J2101A
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
product
High Voltage Differential Probe
ADF25A
Permits conventional grounded oscilloscopes to be used for the display and measurement of multiple floating signals with high common mode voltages
-
product
Tone & Probe Kits
Triplett Test Equipment & Tools
ProTone Wire Locator Kit features a powerful tone generator and a filtered, ultra-bright lighted probe. The CTX590 functions as a high quality wire locating tool that uses an inductive probe to sense a tone placed on the wires by its associated tone generator. The tone generator provides RJ11, RJ45 and insulated alligator clip connections. The Red/Green LED on the probe indicates continuity, voltage, and polarity. The probe also includes an ultra bright LED tip, fluorescent light noise filter and sensitivity control. The CTX590 can be used for tracking down short circuits, telephone central office connections, and other wire locating applications. Includes (2) 9V batteries and case.
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP025-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
TightSight™ Clamp Meter, 1000A AC/DC W/TRMS
61-775
*TightSight™ second display*Tapered jaws with hook tip*True RMS current and voltage*AC/DC voltage*Audible continuity*High frequency rejection**Peak hold*Max/min hold*Data hold*Selectable audible and visual alerts when potentially hazardous voltages are detected at the probe terminals*Selectable auto power off*Backlit display*Low battery indicator*Reads accurately on noisy electrical circuits
-
product
500 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP018-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Hi-Z HV AC Voltmeters
B-1013
*25kV, 50kV or 100kV Meter with integral line to ground Probe*Phasing or line to line with additional Probe*Optional 6ft or 9ft Collapsible Hotsticks*Voltage source for testing Voltmeters and Probes*Optional test point contamination indicating Megmeter®*High voltage cable clamps or hooks*Heavy duty carrying case
-
product
High Voltage Probe
HVP-40DM
*DC 40KV CAT II Pollution 2.*2000MΩ Impedance.*3999 LCD display.*Accuracy 1.0% full range.*T.C. 100 ppm/oC*400V/4KV/40KV, 3 range.*Resolution 0.1V/1V/10V.*PEAK HOLD, Auto power off.*CE, TUV GS, UL, CUL, IEC1010
-
product
7kV, 100 MHz, 2.5 pF, 40 M, Rise Time < 3.5 ns, High Voltage Differential Probe
T3HVD7000-100
7kV, 100 MHz, 2.5 pF, 40 M, Rise Time < 3.5 ns, High Voltage Differential Probe.
-
product
High Voltage Differential Probes
A high voltage differential probe is used for measuring the voltage difference between two test points where neither test point is at ground. High voltage differential probes from Tektronix can be used for signals up to 6000 V. These probes are the best choice for making non-ground referenced, floating or isolated measurements in large part due to their common mode rejection capability. These products are designed, manufactured, and serviced by Tektronix.
-
product
High Voltage Probes To Measure Primary Waveforms With A Power Analyzer
Volt Litewire
The Litewire is a true RMS meter designed for use by electric utilities to sense currents or voltage waveforms from the primary side of their distribution networks.
-
product
Isolated Hall Effect Current Sensors
Isolated Hall Effect current sensors provide accurate high bandwidth current sensing. Vektrex offers models to 320A. For use, the 50-ohm voltage output is connected directly to an oscilloscope or data acquisition system. VCS sensors are magnetically isolated like clamp-on oscilloscope probes. With secure cable attachment, repeatability is ensured.
-
product
High Voltage Non-Contact Current Probe
P02-0802
The TESCO High Voltage Non-Contact Current Probe (Catalog No. P02-802) was developed using current sensor technology. It is a two-piece, True RMS ammeter with a fiber optic link between the high voltage sensor and the readout at ground potential. The sensor is mounted on a hotstick and slipped over a high voltage line.
-
product
6kV, 100 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3605A
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
Circuit Tester
TE6-0720
Hangzhou Tonny Electric & Tools Co., Ltd.
*For use on cars, trucks, boats, trailers and motorcycles*Needle point probes *Use to trouble shoot both primary and secondary circuits*Use this tester to check primary circuits of 6/12V*On secondary or high voltage circuits you can check spark plugs