Process Calibrators
Assure process control signal validity.
-
Product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
Calibration Cable
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
Product
Insulation / Continuity Tester Proving Unit
PU250
-
The PU250 allows simple and quick check of insulation resistance and continuity for all makes of I/R testers.Regular checks outside of the formal calibration process are required for compliance with BS7671 and Part P.Proving unit to enable compliance to the requirement to maintain records of regular checks on the measurement characteristics and accuracy of test instruments.
-
Product
CalPod Drive Cable, 40 GHz, 2 Meter
85553A
Calibration Cable
This cable provides the bias voltages and control signals for operation of the 40 GHz CalPod modules. This cable is supplied with the 85540/41/42A CalPod modules.
-
Product
PXIe-8830MC, Intel Core i7 Processor PXI MultiComputing Processing Module
783564-33
Processing Module
The PXIe‑8830mc allows two or more intelligent systems to exchange data using PCI Express technology. Featuring an Intel quad-core processor, the NI PXIe‑8830mc can be installed in any PXI Express peripheral slot. It runs on the LabVIEW Real‑Time OS and can act as a coprocessor to offload the processing from the main embedded controller in the system.
-
Product
Multiport Electronic Calibration Module (ECal), DC To 20, 6-ports
N7564A
-
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 20 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
Calibration Cable, 78-pin D-type, Thermocouple Simulator Modules
40-975-078-1m
Calibration Cable
This cable assembly is specifically designed to connect to the 78-Pin D-Type port on the front panel of Pickering Interfaces Thermocouple Simulator Modules 41-760 and 41-761 enabling calibration via an external DMM.
-
Product
Linear Measurement Kit
55280A
Mechanical Calibration Kit
The Keysight 55280A Linear Measurement Kit, used with the Keysight 5530 Laser Calibration System, includes the optical equipment needed to measure linear distance (displacement) and velocity. The kit contains a Keysight 10766A Linear Interferometer, two Keysight 10767A Linear Retroreflectors, mounting hardware, andtransit case.
-
Product
Calibrator Process
VA70034
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Loop calibrator This Calibrator is use to measure or output 0 to 24 mA DC current loop, and 0 to 20 V DC voltage.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (m)
85562A
Mechanical Calibration Kit
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight
-
Product
Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm
85132F
Calibration Cable
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.
-
Product
Process
HY-OPTIMA
-
H2scan's HY-OPTIMA™ product line includes a range of real-time, in-line portable hydrogen monitors & hydrogen analyzers for process optimization in industrial applications. The end result is increased product yield, improved hydrogen utilization, and extended catalyst life.
-
Product
Calibration
-
Formal quality systems, such as those described in ISO 9000, require gauges to be properly controlled, logged and in calibration. Increasingly, users are specifying that the readings taken by gauges are traceable to National Standards. There are three types of coating thickness standards available from Elcometer: calibration foils, coated standards and zero test plates.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
Mechanical Calibration Kit
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.
-
Product
Process Tachometer
TCT101-3ABC
-
The Process Tachometer TCT101-3ABC is a panel mount Process Tachometer which can measure frequency up to 100Khz with Encoders and 2 or 3 wire proximity switches. There is also a function to store the maximum frequency and the lowest frequency.
-
Product
Calibration
EMC Test Antennas
-
There are some changes in the calibration standard ANSI C63.4 concerning the calibration procedures of hybrid antennas, also the newly issued standard - CISPR 16-1-6 dealing with EMC antenna calibration is covered by our services. You are very welcome to consult Seibersdorf Laboratories calibration experts for the recommended calibration procedures of the most common radiated emission test standards.
-
Product
Humidity calibration with humidity calibrator
HUMOR 20
-
The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. The humidity calibrator HUMOR 20 developed by E+E is the ideal reference instrument for these requirements and is traceable to international standards. The HUMOR 20 can be used in the humidity range of 10-95% RH both for monitoring cylindrical sensors and also for monitoring instruments with cubic dimensions.
-
Product
Calibration
-
Calibrations of electronic equipment is one of the activities that Kiwa Dare offers to its clients. these calibrations are under accreditation in the field of electrical quantities. Besides calibrations in the field of DC current, DC voltage and low frequency (test and measuring) equipment, Kiwa Dare is specialized in calibrating high frequency measuring equipment and in particular EMC equipment in a frequency range of (DC) 40 GHz. New the site validation calibrations whereby Kiwa Dare can calibrate shielded rooms (Faraday room) and anechoic chambers under accreditation.
-
Product
Wet Processing Systems
-
Surface preparation using sustainable practices is critical to ensuring the reliability of your advanced microelectronics destined for automotive applications, medical devices, 5G and cloud storage.
-
Product
Target Tracking/Image Processing
-
Our automatic video trackers and image processors are at the heart of a wide range of commercial, military and paramilitary systems where they provide the highest performance solutions in the smallest, fully environmentally proven hardware packages.
-
Product
Process Analytics
-
The data-driven examination of business workflows to map, monitor, and improve performance in real time.
-
Product
Process Analyzer System
Process
-
Process Analyzer System is a facility to measure necessary parameters such as hydrocarbons to help optimize the manufacturing process. The analyzer is chosen so that it best meets the customer requirements.
-
Product
Data Processing System
CRS-D8I-3VF1
System
The CRS-D8I-3VF1 VPX system’s I/O flexibility is capable of meeting a large number of configurations. It is designed to support Abaco Systems’ Intel 3rd generation Core i7 3U SBCs, Gigabit Ethernet switch, video compression card, CUDA-based graphics cards and a MIL-STD-1553/ARINC429 multi-protocol card.
-
Product
Process Analyzers
-
Knick Elektronische Messgeräte GmbH & Co. KG.
Industrial meters for pH, ORP, conductivity and oxygen. In 2- and 4-wire technology, explosion-proof.Bus Communication: HART, FOUNDATION Fieldbus, Profibus DP and PA. Robust industrial housing with high IP protection. Suitable for outdoor use. For analog and digital sensors. Simple intuitive operation. From DIN rail transmitters up to the modular system.
-
Product
Process Carrier Pallets
Metalic Family
-
Process carrier pallets to carry the circuit boards through pick-n-place, IR reflow, gold wire bonding, epoxy dot encapsulating, and final fuctional test. Test Electronics will precision drill and customize pallets for your circuit board. Click on the Quote tab on the left then click on the Carrier Pallets tab to get an instant quotation on your process carrier pallets. Process carrier pallets can be designed to carry your circuit boards through assembly, wash and final test.
-
Product
Calibration Software
-
AMETEK Sensors, Test & Calibration
Our calibration software provides an easy way to calibrate gauges, RTD´s, thermocouples, transmitters, thermoswithes, and pressure switches. Complete a full calibration from entering the details of the gauge to printing out a calibration certificate. Reduce operating time by automating calibration procedures, reduce sources of error by automatically reading and storing values from the reference, and customize certificate templates to fit your needs.
-
Product
Antenna Calibration
-
TDK Test Services offers testing to domestic and international EMC test regulations, including IEC, ISO, CISPR, and SAE. Test services are offered in our 3m semi-anechoic chamber, 3m fully-anechoic chamber, 10-meter open area test site, and our shielded conducted test chamber.
-
Product
Calibrators
-
Fluke offers a wide range of pressure calibration tools with precision pressure measurement from 15psi/1 bar to 10,000 psi/690 bar boasting 0.025% full-scale accuracy. Everything from simple test gauges to calibrators with built in electric test pumps. Easy to use, rugged and reliable construction and an industry best 3-year warranty. Fluke means pressure.





























