Filter Results By:
Products
Applications
Manufacturers
Current Transformer Test
measures insulation, excitation current, turns ratio, winding polarity saturation and/or winding resistance. Current Transformers
See Also: Transformer Test, Transformer Testers, Current Transformer Test Set
-
product
Fully Automatic Transformer Winding Resistance Tester
Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.
-
product
Primary Injection Kit
Prima Series
Prima Series is designed for Primary Current Injection Testing of Current Transformers, Protection Relays & Circuit Breakers during their Factory Test, Commissioning and Routine Testing.
-
product
Current Caliper
KH23101
Beijing KeHuan Century EMC Technology Co,.LTD
The KH23101 current caliper is a toroidal transformer used to measure EMI current. When measuring, the caliper does not directly touch the electrical conductor or the cable under test. The conductor passing through the caliper window is used as the single-turn primary wire of the transformer, and the secondary is designed to be multi-turn. Use with 50 Ω receiving system (such as EMI electromagnetic interference field strength meter or spectrum analyzer). In order to facilitate installation and rapid measurement of EMI current, it is designed as a caliper that can be opened.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TT Series
RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
product
904 Benchtop Six Phase 30A
Weshine Electric Manufacturing Co., Ltd
1. The instrument has standard six phase voltage and six phase current output. It can test not only traditional relays andprotection devices, but also modern micro-computer protection devices, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. can be connected to laptop (optional) to run.Laptops and industrial computers use the same set of software, so there is no need to relearn the operation method.
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
product
Transformer Testing Equipment
Offering you a complete choice of products which include Automatic Transformer Turns Ratio Instruments (ATRI- 3), Automatic Transformer Turns Ratio Instrument (ATRI-201), VTRI-2000 ( Transformer turns ratio instrument ), Current Transformer Test Set (CTC-1), Potential Transformer Tester ( PT Tester ) and Current Transformer Tester ( CT Tester ).
-
product
Transformer Testing
The ART-3D series of Automatic Ratio Testers are precision instruments, designed to measure the turn ratios, phase displacements, excitation currents of single phase and three phase power, distribution and instrument transformers in conformity to the IEEE C57.12.90 & IEC 60076. Now featuring an enhanced test lead design, the ART-3D is the perfect instrument for real-life field usage. ART-3D series also has Anti Induction circuit which makes it suitable for system voltages upto 765KV.
-
product
CT/PT Test Set
PCT200Ai
PCT200Ai is the CT/PT test set (current transformer analyzer) that can finish various current transformer test of different CT and plus reference testing functions of PT. Compared with PCT200i, its accuracy is higher.
-
product
Transformer Winding Resistance Meters
TWA Standard Series
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
product
MCB Magnetic (Instantaneous) Trip Test Bench
The test bench is specially built for low voltage- B, C & D curve MCBs. Specially designed custom built jigs are able to accommodate single, double, three and four pole MCBs. Decades of experience has helped us to design current source (transformer) in a special way such that good current regulation and high accuracy is ensured with a variable range without the use of any variable transformer in the system. The product is better than the competition with conventional technology at a lesser price!
-
product
Current And Voltage Transformer Test Set
iCT1
iCT1 - CT/VT Test Set is the NEW and most advanced portable equipment capable to test current, voltage and combined transformers.With the low voltage method, known as "DC method", iCT1 is able to test Current Transformers with a very high saturation voltage, up to 30 kV, in a complete safety mode. Quick and easy to use tool, iCT1 allows to perform tests in one shot without changing the connection to the CT, thanks to the integrated 5-TAP Switchbox.
-
product
Transformer Ratiometer
TR-1C
Model TR-1C Transformer Ratiometer is a precision test set with an easy-to-read in-line digital readout from 0.00001 to 1.00000, suitable for testing all types of single and three-phase power distribution, potential and current transformers.
-
product
AC/DC Withstand Voltage Test
WB2671A/WB2671B
• Output voltage: 0-5kV (AC/DC); • Cutoff current range: AC 0~20mA (WB2671A)/0~100mA (WB2671B); DC 0-20mA; • Test time: 1-60s; • Transformer capacity: 750VA.
-
product
High-Voltage Test Device
PGK 150 / 5 HB
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PGK H. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Testing of medium- and high-voltage cables* DC voltage testing of up to 150 kV output voltage with positive or negative polarity* AC voltage testing - up to 110 kV for switchgear, busbars and insulating elements* Easy-to-maintain 2-piece design
-
product
High-Voltage Test Device
PGK 150 HB
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PGK HB. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Operation as DC or AC testing device* Polarity of the DC voltage can easily be reversed* Robust and durable
-
product
5 A portable digital micro-ohmmeter
MPK-254
The MPK-254 digital very low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1 mA up to 5 A.
-
product
Transformer Degaussing Analyzer
KRI6691
The KRI6691 transformer degaussing analyzer injects current into the test winding by applying ±90V voltage, and collects the terminal voltage and winding current to draw the hysteresis characteristic curve. Linear quantitative analysis of transformer remanence can be performed, and rapid demagnetization can be achieved by tracking the hysteresis curve.
-
product
Compact Automatic Voltage Regulating Relay With Built- In TPI
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.
-
product
Primary Current Injection Test Set
T 3000
T 3000 is a primary current injection testing system designed to perform primary tests requested in substations commissioning. It allows to perform different tests and measurements on current transformers, voltage transformers, power transformers, protection relays, energy meters and transducers
-
product
Transformer Polarity Checker
865
This instrument is used to check the correctness of polarity markings on transformers. In operation, the two leads carrying the test current are connected to one of the transformer windings. The other two leads from the indicating meter are connected to the other winding.
-
product
High Frequency Current Transformer
HFCT Ø 140mm
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
product
TOROIDAL COIL TURNS TESTER
TURNS-TTPT
Digital TURNS TESTER for Counting Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity and DC Resistance.Turns Measurement ( through Toroidal Turns Test Platform) : -> TTPT-100 : 5 Turns ~ 1000Turns-> TTPT-1000 : 500 Turns ~ 10,000Turns
-
product
Automatic Voltage Regulating Relay- Standard Model
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.
-
product
Computer Control 6-Phase Relay Protection Tester
GDJB-PC6
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
1.This tester with standard 6 phase voltage, 6 phase current output,2.Voltage 125V/phase, current 30A/phase, 6 phases in parallel can up to 180A.3.Digital Signal Processor Microcomputer.4.Not only test the traditional relays and protectors, but also test the modern micro computer replays, special for transformer differential protection and transfer equipments.
-
product
Resistance Measurement
PROMET
High-precision micro-ohm measuring systems with adjustable DC test current for determining resistances on circuit breakers or inductive loads such as transformers, for example. The high-precision ohm meters of the PROMET series are used to determine very low electrical resistances in the µΩ range. The adjustable test current of up to 600 A in combination with a four-wire measuring method delivers measurement results which meet stringent accuracy requirements. State-of-the-art power electronics coupled with a robust design guarantee excellent reliability for use as a portable device in switching stations and industrial environments. Typical applications include determining the contact resistance of switchgear devices and determining the resistance on inductive loads such as transformers.
-
product
10 A portable digital micro-ohmmeter
MPK-253
The MPK-253 digital very low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1mA up to 10 A.
-
product
AC / DC Combined High Voltage Test Set
Cambridge Instruments & Engineering Co.
suitable to perform AC High Voltage Power Frequency test on transformers, motors, cables etc. Leakage current can be measured at desired pressure and this set can be used as a source for cable fault burning.
-
product
Test Sets For Transformer Industries
Contemporary Test Sets For Transformer Industries are developed to recognize the potentially disastrous current transformer errors. They prevent the primary current from overpowering insulation and short circuits. They are used for developing a testing and maintenance plan for addressing the errors before any failure to save money and time. With these powerful test sets, they are sure to perform saturation testing to test the knee point of a signal by comparing primary and secondary windings.
-
product
Current Transformer Tester
CT-T1
The CT-T1 is a microprocessor-based Current Transformer Tester that measures CT excitation current, turns ratio, and winding polarity tests, all without having to switch the leads during testing. The instrument has a fully automatic knee point detection (ASA 10/50, IEEE 30°, IEEE 45°). Although includes 5 low side taps and 1 high side tap.