Multiplexers
Combine multiple signals into one signal.
See Also: Switching, Switching Matrix, High Voltage Switching, Switching Matrices, General Purpose Switch
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 11-Bank 18GHz SMA
60-801-211
Multiplexer Module
The 60-801-211 is a 6-channel, 11-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI 5A Power Multiplexer, 2-Bank, 24-Channel, Isolated Common, Independent Isolation
40-651A-112
Multiplexer Module
The 40-651A-112 is part of our range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats.
-
Product
PXI RF Multiplexer: 3 GHz, Dual 1x4, 50 Ω, Terminated
M9146A
Multiplexer Module
The M9146A contains two 1x4 RF switch multiplexers in a single PXI module. It offers 50 Ω inputs with bi-directional switching up to 3 GHz. This module features excellent insertion loss and VSWR for better RF signal integrity as well as outstanding dynamic range for routing RF signals into your measurement equipment. Each path is designed to ensure repeatable RF performance. Connections are made through easy, snap-on SMB connectors.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Single-Mode, 9/125 Fiber
40-850A-514-HI
Multiplexer Module
The 40/42-850A-514-HI is a PXI/PXIe 4-channel multiplexer with ST connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI/PXIe RF Multiplexer, Single 4-Channel, 3GHz, 75Ω, SMB
42-832A-001
Multiplexer Module
The 40-832A-001 (PXI) and 42-832A-001 are 75 Ohm 4 to 1 RF multiplexers with 1 bank in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The design of the 40/42-832A minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.
-
Product
PXI Monitored Multiplexer, Quad 32-Channel, 1-Pole
40-619-204
Multiplexer Module
The 40-619-204 is a high density PXI 2 A multiplexer module in quad 32-channel configuration using high quality electro-mechanical signal relays allowing each channel to switch current up to 2 A and voltage up to 250 VAC/DC.
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 1-Bank 6GHz SMA
60-802-001
Multiplexer Module
The 60-802-001 is a 4-channel, 1-bank RF multiplexer suitable for switching 50Ω signals up to 6GHz. It is part of a range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for between 1 and 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXIe Very High Density Versatile 2 A Multiplexer
42-612B-002
Multiplexer Module
The 40-612B (PXI) and 42-612B (PXIe) Very High Density Versatile Multiplexer module features a wide range of software selectable switching configurations. It is especially useful where a number of high density multiplexers are required with the option of easily altering the channel count as a test system evolves.
-
Product
PXI High Density Multiplexer, 20-Bank, 4-Channel, 1-Pole (SP4T)
40-615A-013
Multiplexer Module
The 40-615A-013 is a 20-bank, 4-channel, 1-pole (SP4T) MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
Product
950~2400MHz DVB-S 4 ways SAT-IF CWDM Optical Transmitter & Receiver
HDBS-4000CW
-
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai HDBS-4000CW series is integrated 4pcs of SAT-IF CWDM standard wavelength optical transmitters with optical receivers in a casing. Through CWDM, Transmitter 4 ways optical multiplex (TX) or demultiplex (RX) through one fiber. It can be well used in transmitting a satellite VL, VH, HL, HH different polarize 4 way SAT-IF signal. It can be easily operated.
-
Product
PXI/PXIe RF Multiplexer, Single 4-Channel, Terminated Common, 3GHz, 50Ω, SMB
40-876A-001
Multiplexer Module
The 40-876A-001 (PXI) and 42-876A-001 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 1 bank in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module exhibits low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
LXI Microwave Multiplexer, SP4T, 3-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-803-503
Multiplexer Module
High performance RF multiplexer suitable for switching microwave signals up to 40GHz with automatic termination of unused signals
-
Product
PXI 5A Power MUX, 4-Bank, 11-Channel
40-651-003
Multiplexer Module
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel.Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
Product
Spectroscopy
NIRS XDS Process Analyzer
-
NIRS XDS Process Analyzer systems can measure a variety of sample types, such as granules, powders, liquids, slurries, or opalescent substances, among others. These analyzers provide fast, nondestructive analysis of pharmaceutical, chemical, and petrochemical products. If required, up to 9 inline measuring channels can be multiplexed with this system.
-
Product
PXI 2A Multiplexer, 2-Bank, 32-Channel, 2-Pole
40-614C-011
Multiplexer Module
This 2-bank, 32-channel, 2 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI-2515, 35-Channel, 0.25 A PXI Signal Insertion Switch Module
778572-15
Signal Module
35-Channel, 0.25 A PXI Signal Insertion Switch Module—The PXI‑2515 is a multiplexer switch module that enables connectivity by routing high-speed digital I/O (DIO) signals between a device under test (DUT) and an NI high-speed DIO device or a parametric measurement device. You can use modules such as PXI Source Measure Units (SMUs) and PXI Digital Multimeters (DMMs) with high-speed digital devices. With the PXI‑2515, you can perform parametric tests on digital pins without external connectivity or impedance mismatch challenges.
-
Product
PXI/PXIe High Voltage Multiplexer, Single 48-Channel, 1-Pole
42-321-109-HI
Multiplexer Module
The 40-321-109-HI (PXI) and 42-321-109-HI (PXIe) are single 48-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
PXI 2A Multiplexer, 1-Bank, 8-Channel, 16-Pole
40-614C-019
Multiplexer Module
This 1-bank, 8-channel, 16 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe RF Multiplexer, Single 4-Channel, Terminated Common, 3GHz, 50Ω, SMB
42-876A-001
Multiplexer Module
The 40-876A-001 (PXI) and 42-876A-001 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 1 bank in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module exhibits low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP10T, 18 GHz, 50 Ω, SMA, Remote Mount, Failsafe
40-788-122-E
Multiplexer Module
The 40-788-122-E (PXI) and 42-788-122-E (PXIe) are dual failsafe SP10T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 40 GHz, 50 Ω, SMA-2.9, Terminated, Remote Mount, Failsafe
42-785C-541-TE
Multiplexer Module
The 40-785C-541-TE (PXI) and 42-785C-541-TE (PXIe) are single failsafe SP6T 40 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI Single SP6T MUX 40GHz 50Ω SMA-2.9
40-784-041
Multiplexer Module
Pickering Interfaces’ 40-784 PXI Microwave Multiplexer Modules have a characteristic impedance of 50 Ohm and are capable of switching signals up to 40GHz. Available in single or dual SP6T or SP4T formats, they are suitable for constructing complex microwave switching networks and provide a range of switching configurations to suit most applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 4-Bank 6GHz SMA
60-801-004
Multiplexer Module
The 60-801-004 is a 6-channel, 4-bank RF multiplexer suitable for switching 50Ω signals up to 6GHz. It is part of a range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for between 1 and 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
LXI Dual 8 Channel Fiber Multiplexer ST, Multi-Mode
60-851-312
Multiplexer Module
The 60-850 and 60-851 are LXI conformant fiber optic multiplexers that use MEMS switching technology to ensure fast and reliable switching of single-mode (60-850) or multi-mode (60-851) optical signals being carried on fiber connections. The 60-850/851 is available with a variety of connector options and in a variety of multiplexer arrangements. Loop-thru versions are also available for easy multiplexer expansion.
-
Product
PXI/PXIe RF Multiplexer, Dual 4-Channel, 3GHz, 75Ω, SMB
42-832A-002
Multiplexer Module
The 40-832A-002 (PXI) and 42-832A-002 (PXIe) are 75 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The design of the 40/42-832A minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 8-Bank 6GHz SMA
60-801-008
Multiplexer Module
The 60-801-008 is a 6-channel, 8-bank RF multiplexer suitable for switching 50Ω signals up to 6GHz. It is part of a range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for between 1 and 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI High Density Multiplexer, 2-Bank, 40-Channel, 1-Pole
40-615A-017
Multiplexer Module
The 40-615A-017 is a 2-bank, 40-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 50/125 Fiber, SC/PC Connectors
42-852A-218-M50
Multiplexer Module
The 40/42-852A-218-M50 is a PXI/PXIe 8-channel multiplexer with SC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
LXI Microwave Multiplexer, SP6T, 14-Bank, 50GHz, 50Ω, SMA-2.4, Terminated
60-800-714
Microwave Multiplexer
High performance RF multiplexer suitable for switching microwave signals up to 50GHz with automatic termination of unused signals
-
Product
PXI Solid State MUX, 4 pole, 40 channel
40-680-404
Multiplexer Module
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.





























