Product
Intel 80486 DX4
MS 1502
-
- ATE- Data Acquisition System- Process Control Industry- Industrial Automation
-
Product
SH68-68R1-EP, Shielded Cable, Right Angle Connector, 1 m
187051-01
Multifunction Cable
68-Pin Female SCSI to 68-Pin Right-Angle Female SCSI, Twisted Pair, Shielded, 1 m Multifunction Cable - The SH68F-68R1F-EP Cable, sometimes referred to as SH68-68R1-EP, connects NI DAQ 68-pin devices to 68-pin accessories. The right-angle connector is useful for small spaces where clearance is limited.
-
Product
8-Channel Resistivity/IP Data Acquisition System
ZZ Universal
-
ZZ Resistivity Imaging Pty. Ltd.
Measurment variables Resistivity, IP and SPOperating time 30 data points/secondMeasurement range From -10V to +10VSP compensation Automatic cancellationResistivity cycle times From 0.1S to 10SAutomatic multi-electrodes YesData samping rate 100KHZData storage UnlimitedData transmission USBPower supply External 12V batteryOperating temperature -20 to +70 oCOperating Humidity 98% RHWeight 5.3 kgDimension 339 x 295 x 152 mmBuilt-in GPS Optional
-
Product
8/4-Ch, 14-Bit, 20MS/s/ch Simultaneous Analog Input PCI Express DAQ Card
PCIE-1843
-
8 or 4 x Simultaneously Analog Inputs, up to 20 MS/s14-bit resolutionSupports digital and analog triggersWide input range up to 20 Vpp (±10 V range)Onboard FIFO memory (65,536 samples)
-
Product
PXI MUX 4 Banks of 16 Channel 2 Pole
40-610-022-4/16/2
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
WiFiScope WS5: 200 MS/s 250MHz BW, 2 Channel, Digital Storage Oscilloscope, 20MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder
WS5-220XM-W5
-
TiePie engineering has introduced the WiFiScope series oscilloscopes. The new range WiFi oscilloscopes can be used via an ethernet connection (LAN, WiFi or WAN) but also still with a USB 2.0 / 3.0 connection. The built-in battery gives the WiFiScope the possibility to perform fully wireless measurements. Measurements can then be performed completely galvanically isolated, and over long distances. This wireless PC-based data acquisition instrument offers the user more possibilities for measurement applications.With a WAN connection, worldwide measurements can be performed. Specific knowledge on networks is not required. The Multi Channel software gives an overview of the available USB instruments and network instruments. Simply tick the instrument and measuring can start. The WiFi oscilloscope has the following advantages: fully wireless measurements via WiFi are performed (galvanically isolated) because of the built-in battery mobile measurements are possible, e.g. on transport systems and moving installations LAN and WAN data acquisition is available for long distance measurements continuous realtime highspeed data acquisition over both WiFi and LAN/WAN are available USB measurements for stand-alone applications and highspeed data acquisition up to 200MSa/s.
-
Product
PXI High Density Multiplexer, 10-Bank, 16-Channel, 1-Pole
40-615A-003
Multiplexer Module
The 40-615A-003 is a 10-bank, 16-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful here a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
Product
PXI Very High Density Mux Dual 10 Ch 8 Pole
40-670A-022-10/8
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
Digital Reconfigurable I/O Device
ITA
The Digital Reconfigurable I/O (RIO) Device features user-programmable FPGA for onboard processing and flexible I/O operation. You have complete control over the synchronization and timing of all signals and operations along with custom onboard decision-making that executes with hardware-timed speed and reliability. You can configure user-defined hardware for a wide variety of applications, such as custom digital DAQ, high-speed waveform generation, sensor simulation, hardware-in-the-loop (HIL) test, custom digital communications protocols, bit error rate testing, and other applications that require precise timing and control.
-
Product
PXI Multiplexer, Single 64-Channel, 1-Pole
40-630A-022-64/1
Multiplexer Module
The 40-630A-022-64/1 is a single 64-channel, 1-pole PXI multiplexer and is part of our series of general purpose multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
Multiplexer/Recorder
AIM-2004/2005R/2006
-
Curtiss-Wright Defense Solutions
The AIM-2004/2005R/2006 units support external recorders and are designed to accept up to four, five or six data acquisition cards that provide various interfaces.
-
Product
1-Channel DAQ Module
FMC160
-
Sundance Multiprocessor Technology Ltd.
The FMC160 provides one 12-bit A/D channel at 3.6Gsps and one 14-bit D/A channel at 5.6Gsps (2.8Gsps direct RF synthesis) clocked by either an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. In addition, a trigger input for customized sampling control is available to users. The FMC160 daughter card is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1).
-
Product
Analog Output DAQ Cards
-
Analog output cards are ideal for DAQ applications where multiple A/O channels are needed for voltage and current output.
-
Product
Rugged, Long Gauge Length Extensometers
Model 3543
-
Jinan Testing Equipment IE Corporation
With over 15 years of proven reliability in the world’s most demanding testing environments, the Model 3543 extensometer is designed to survive in those applications where standard axial extensometers would not. Designed by Epsilon, the Model 3543 was created to survive specimen failure by separating into two halves, thus preventing permanent damage to the module body. During operation, the upper half of the extensometer pulls out of the main body. Tapered measuring beams activate strain gaged flexures within the unit. This unique design allows long measuring ranges, yet retains compatibility with electronics for strain gaged transducers. These models offer high accuracy and are light weight but rugged, with low operating force. They are tension only units.The units have hardened tool steel knife edges. Standard quick attach wires provided with the extensometer work on flat specimens up to 12 x 31 mm (0.5 x 1.25 inch) and on rounds up to 25 mm (1 inch) diameter. Optional quick attach kit wire forms are available for use on larger samples. See Model 3542L for long gauge lengths with smaller measuring ranges.The Model 3543 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
CB-50LP Low-Cost, Unshielded I/O Connector Block
777101-01
Terminal Block
50-Pin Male IDA to 50-Pin, Female Screw Terminal, Panel Mount Terminal Block - The CB-50LP provides 50 screw terminals for connection to I/O signals from 50-pin NI data acquisition devices. The CB-50LP includes one 50-pin header for direct connection to 50-pin cables and metal standoffs for use on a desktop or for mounting on a custom panel.
-
Product
Data Acquisition & Control Systems
Series 6000
-
An innovative and fully integrated modular transducer conditioning, acquisition and control system, the Series 6000 has unparalleled performance and accuracy. From two to many thousands of channels, high & low speed, analog & digital, Series 6000 acquires measurement data from virtually all types of sensors and is fully customizable to fit the needs of any test facility. Large & small, AC & DC powered enclosures are available for nearly any test environment. Analog and digital I/O modules condition, amplify, filter and digitize signals from transducers. Turnkey and/or API software is available, helping facilities get up and running quickly.
-
Product
PXIe-7858, Kintex-7 325T FPGA, 1 MS/s, DRAM PXI Multifunction Reconfigurable I/O Module
784147-01
Multifunction Reconfigurable I/O
Kintex-7 325T FPGA, 1 MS/s, DRAM PXI Multifunction Reconfigurable I/O Module—The PXIe‑7858 features a user-programmable FPGA for high-performance onboard processing and direct control over I/O signals to ensure complete flexibility of system timing and synchronization. You can customize these devices with the LabVIEW FPGA Module to develop applications requiring precise timing and control such as hardware‑in‑the‑loop testing, custom protocol communication, sensor simulation, and high-speed control. The PXIe‑7858 features a dedicated A/D converter (ADC) per channel for independent timing and triggering. This design offers specialized functionality such as multirate sampling and individual channel triggering, which are outside the capabilities of typical data acquisition hardware. The PXIe‑7856 also includes peer‑to‑peer streaming for direct data transfer to other PXI Express modules.
-
Product
Single 8x8 1-Pole High-Density PXI Matrix Module
40-520-204
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
4-Slot Industrial DAQ Chassis Module For AMAX-5000
iDAQ-964
Chassis
PCIe interface connecting to AMAX-5000 series controllersLED status indicators4 iDAQ slots2 programmable function pin for timing signal (trigger, clock) input/output
-
Product
Video cameras
-
High-speed Video Cameras and Video Data AcquisitionDewesoft video data acquisition supports standard and high-speed video cameras (DirectX and GigE), thermal cameras for temperature acquisition and visualization, and Ultra-High Speed video synchronization.
-
Product
3-AXIS DIGITAL AC GAUSSMETER: 1-200 kHz
IDR-200
-
Integrity Design and Reseach Corp.
Typical Applications include checking the frequencies and magnetic fields (BW: 1 kHz -200 kHz) produced by equipments such as computer monitors, television sets, video display terminals, induction heaters, industrial, Radar, scientific/medical equipment, walk-through/hand-held detectors and ground wave energy network; etc. For more information about VLF magnetic fields and the VLF gaussmeter , see the paper titled "Very-low-frequency electromagnetic field detector with data acquisition," IEEE Trans. Instrum. Meas.,vol. 58, no. 1, pp. 129-140, Dec. 2008. by S. Hanna.
-
Product
PXI MUX 2 Banks of 64 Channel 1 Pole
40-610-022-2/64/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
BNC-2110, 68-Pin SCSI to Female BNC and Spring Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block
777643-01
Terminal Block
68-Pin SCSI to Female BNC and Spring Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block - The BNC-2110 can be used with various NI multifunction I/O and analog output devices. The BNC-2110 simplifies the connection of analog signals, some digital signals, and two … user-defined connections to the data acquisition device while maintaining the integrity of your measurements with a shielded enclosure. It includes a DIN Rail and a desktop mount option.
-
Product
Breadboard to DAQ Converters
0001026-1 / -2
-
VI Control Systems has designed two converter boards that make it easy to connect data acquisition boards to breadboards and allow easy computer control and monitoring of prototyped electronic circuits. The converter boards are 0.8 x 3.5 inches and have silk-screened pin numbers for every pin on the board. The 68-pin SCSI converter can also be used to connect 68-pin SCSI cables to prototype solder boards that have 0.1 inch centers.
-
Product
SH25M-10F Cable, 25-Pin Male D-SUB to 10-Pin Female COMBICON, Shielded Multifunction Cable
190654-01
Multifunction Cable
25-Pin Male D-SUB to 10-Pin Female COMBICON, Shielded Multifunction Cable - The SH25M-10F Cable, sometimes referred to as SH10F-25M, connects C Series DAQ devices with a 10-pin screw terminal to a 25-pin D-SUB. The SH25M-10F Cable is offered in different lengths.
-
Product
Application Software
-
Application software is a key element of a premium measurement system. Applying this software approach to a broad range of radiation detector hardware and data acquisition systems, ORTEC software offers comprehensive nuclear measurement solutions that provide integrated hardware control, analysis, and display in a single, easy-to-use package.
-
Product
Firmware Engineering Projects
-
Precision Development Consulting Inc
Hand control module for teleprompter, Analog data acquisition and filtering, High-Power Arc Lamp Power Supply Controller and RTP gas flow and Vacuum System controller, Disk drive company test racks, Disk Drive Spindle Motor Tester, Disk Drive Head Stack Tester, Wafer photoresist coating and development system control PC boards, Nuclear Plant secondary water temperature monitor
-
Product
Digitizers/Oscilloscopes
-
From entry-level to high-end, data acquisition to digital input/output, ADLINK provides a diversity of modular instruments with market-leading price/performance ratio, for bigger and better measurement and automation systems. Now high-speed digitizer, switching, simultaneous data acquisition, high-density multi-function data acquisition, analog output, digital multimeter, and arbitrary waveform generator categories are all available.
-
Product
WiFiScope WS6+SureConnect: 200 MS/s 250MHz BW, 4 Channel, Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
WS6-200XMS-W5
-
TiePie engineering has introduced the WiFiScope series oscilloscopes. The new range WiFi oscilloscopes can be used via an ethernet connection (LAN, WiFi or WAN) but also still with a USB 2.0 / 3.0 connection. The built-in battery gives the WiFiScope the possibility to perform fully wireless measurements. Measurements can then be performed completely galvanically isolated, and over long distances. This wireless PC-based data acquisition instrument offers the user more possibilities for measurement applications.