Filter Results By:
Products
Applications
Manufacturers
-
product
Needle Flame Test Apparatus
Needle Flame Test Apparatus is designed to carry out fire hazard testing. Flammability test is to check the ‘Resistance to Fire’ of electrical insulators that touch directly conducting parts & also parts of insulators. Testing with regard to fire hazards can be done by creating exactly the conditions occurring in practice. However, this is not possible in most instances. Hence for this test, the actual conditions are simulated as closely as possible by the Needle Flame Test Apparatus.
-
product
IEC60695 Needle Flame Test Machine
CX-Z18
Shenzhen Chuangxin Instruments Co., Ltd.
Needle Flame Tester is made according to Standard IEC60695 and GB5169, meanwhile it’s a synthesis test equipment that can meet related standard requirements. It’s mainly used to simulate technical evaluation interior equipment. It’s applied to the risk of ignition test of electrotechnical equipment, parts and elements, also suitable for the risk of ignition test of solid electrical insulating materials or other combustible material.
-
product
Needle Flame Combustion Tester
Shanghai Dean Electrical Co., Ltd
The touch screen control needle flame combustion tester is developed according to the requirements of the needle flame combustion test in the standard
-
product
ZY-3 Needle Flame Test
ZY-3/ZY-3S
According to IEC60695-2-2 and IEC60695-11-5, ZY-3/ZY-3S Needle Flame Test is applied in the production and quality control department of lighting instrument, hyperpiesia electrical apparatus, domestic appliance, machine electric appliance, electrical machine, power tool, electronic instrument, electrician instrument and technical equipment. Also, it is fit for the industry of insulation material, engineering plastics and solid combustible material.
-
product
Needle Hydrophones
Our high-performance needle hydrophone system consists of a range of interchangeable PVdF needle hydrophone probes, a submersible wide-band amplifier and a DC coupler.
-
product
Integral Intelligent Flame Detector
FS-100
FS-100 utilizes SMT technology which integrates a photoelectric sensor, a microprocessor, and a Human-Computer Interface (HCI) and an output interface together, sending out various outputs including an ON/OFF flame signal, a fault signal, a 4-20mA signal, and an RS-485 output (meets the MODBUS standard) via the quick connector.
-
product
Needle Valves
Needle valves are designed for laboratory and industrial applications for regulating corrosive gases and liquids or for high purity service. They can also be used as bubble tight shut-off valves.
-
product
Flame Photometers
Flame Photometers are used widely in the measurement of alkali elements concentration in all sample types in: Mineral Extraction, Oil Industry, Paper Industry, Pharmaceuticals, Soil Analysis, Utilities, Food & Beverage, Chemical Manufacture and Fertilizer and Clinical laboratory testing and Pathological study in medical health.
-
product
Needle Microprobe
MT-26/2HT
Fast-response 26 gauge needle probe, (needle length is 2 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
product
Flame Ionization Detector
A flame ionization detector converts a hydrocarbon gas concentration into an electrical signal. The flame is hydrogen fueled and burns in hydrocarbon free combustion air. Either side of the flame are two electrodes between which an electric field is generated by means of a polarization voltage. The sample is pre-mixed with the fuel gas and heated in the flame to a temperature at which the hydrocarbon molecules ‘crack’ and CH fragments appear. These CH fragments are oxidated by the oxygen in the combustion air resulting in the formation of CHO+ ions. The ion current then passes to the electrodes and the resulting current measured is proportional to the quantity of C atoms derived from organic compounds.The Thermo-FID features two separate microprocessor controlled pressure compensations to avoid any influence from environmental or sample conditions. In addition, the complete Thermo-FID range of analyzers are equipped with a flame trap that is used as a heated sample inlet filter. The measurement chamber and all material in contact with the sample gas are heated between 120°C and 200°C to avoid condensation.
-
product
Needle Microprobe
MT-26/4HT
Fast-response 26 gauge needle probe, (needle length is 4 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
product
Manual Test Adapter With Rigid Needles
Frequently, manual test adapters are required for the functional and IC test. In order to contact the test subject, spring contact probes are often installed in the adapter, but the pitch of the spring contact probes is approx. 1.27 mm and thus too great for certain applications.
-
product
Flame Detector
SMC 3100
The SMC 3100 Series Flame Detector utilizes a tri-spectra design (UV, IR and visible light spectrums) to provide continuous and reliable flame detection. The 3100 Series design provides the ability to detect flames from both hydrocarbon and non-hydrocarbon sources, making it ideal for a facility where the flame source could be generated from a variety of gases.
-
product
Curved Needle Test Systems
The Instron® Curved Needle Testing System is ideally suited for testing needles used in wound closure or surgical procedures. This system provides a platform for two different needle testing solutions: one for curved needle puncture testing to ASTM F3014 and the other for cantilever bend testing.
-
product
Needle Microprobe
MT-23/3HT
Fast-response 23 gauge needle probe, (needle length is 3 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
product
Series Flame Detector
DF-TV7
Teledyne Gas & Flame Detection
The device offers a wide range of output options, as standard and is suitable for use in SIL 2 applications. The detector can be configured to communicate with a wide range of fire panels, controllers, and PLCs and offer HART 7 and Syntel (Lonworks) protocols for addressable event monitoring. The devices come standard with a configurable 4-20mA or 0-22mA (PLC) output, two configurable alarm relays, and two detector status LEDs.All MultiFlame detectors are equipped with a continuous optical lens auto-check to ensure that the optical path is clear and that the detector functions properly. Sensors can be replaced easily in the field without removing any cable glands. Devices are easy to test and configure using a TLU600 wireless hand-held unit that is approved for use in hazardous areas. The TLU600 can also be used for wireless testing of the optical and output circuits. The TLU600 can also be used for wireless testing of the optical and output circuits.
-
product
Flame & Other Plastics Testing
Educated Design & Development, Inc.
Plastics are tested to determine their flammability burning characteristics (Flame rating), their ignition potential due to thermal and electrical sources, their resistance to electrical tracking, and other electrical characteristics. The specific test required on a plastic depends on the type of component or end-use product, as well as the environment in which the plastic is used. This test equipment meets most UL, CSA, IEC, EN and other international safety standards.
-
product
HVR-LS Horizontal Vertical Flame Tester
HVR-LS/HVR-LSS
This equipment meets the requirements of ANSI/UL94, IEC60950-1, IEC695-2-2 and GB Standard. It is used to test the appliances and plastic materials parts of electrical equipment for the horizontal, vertical flammability test. The product tank shell is irony spray, and configured a transparent viewing window, the digital meter shows the burning time, afterflame time, afterglow time, this device has beautiful appearance, is easy to use and has reliable performance.
-
product
OptiStroke™ Needle Stroke Detection System
The patented OptiStroke system reduces product waste and confirms hot melt adhesive dispensing performance by verifying valve actuation and fatigue. Ideal for applications where product-yield loss is critical, the system is compatible with Nordson Universal™ modules, Speed-Coat™ modules and Harmony modules.
-
product
Needle Microprobe
MT-29/5HT
Fast-response 29 gauge needle probe, (needle length is 5 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
product
Curved Needle Test Systems
The Instron® Curved Needle Testing System is built on the 5900 system platform and is ideally suited for needles used in abdominal, fistula, vascular, intestinal, or other surgical procedures. This system provides two different needle testing solutions: one for curved needle puncture testing and one for bend testing. The curved needle puncture testing fixture is used to evaluate needle sharpness and insertion force, while the needle bend testing fixture is used to evaluate flexural properties of the needle during use. With its tabletop design, the Curved Needle Testing System has a small footprint and takes up minimal bench-top space. The testing system operates with Instron Bluehill® Universal software that provides test control, data acquisition, test results, and reports, as well as a large library of calculations.
-
product
Probe Needles for Wafer Sort and Test Applications
Advanced Probing Systems, Inc.
APS is the global leader in the manufacture of probe needles used in cantilevered probe cards. All probe needles used in wafer sort are manufactured according to customer specifications using stringent in-process quality assurance procedures.
-
product
Flame Photometers
Flame Photometer applies the emission spectrum as the basic principle, which uses the flame heat and excites part of the atoms in alkaline earth metal. The atoms receive energy and transfer it to the old energy level. When the atom is at a normal energy level it releases the energy.
-
product
Cross Needle Meter. 1.8 - 60/144/440
MFJ-864
This new MFJ Cross Needle SWR/Wattmeter covers HF thru VHF 1.8 - 60MHz, 144 MHz and 440 Mhz bands. It features separate HF and VHF / UHF directional couplers, each with its own SO-239 connectors. This lets you connect your HF and VHF/UHF transceivers at the same time.
-
product
Needle Pressure Gauge
102
The Elcometer 102 Needle Pressure Gauge is designed to measure air pressure up to 20bar (300psi) in blast and air hoses. Pressure drop is responsible for decreased production rates, increased abrasive consumption and reduced anchor profile in abrasive blasting systems.
-
product
Palladium Alloy & Beryllium-Copper Probe Needles
Advanced Probing Systems, Inc.
APS has been providing high precision, high volume Tungsten Electrosurgical Needles for over 20 years in Colorado where the product was invented. Our unique Chemical machining process can produce polished electrosurgical needles for diameters from .177mm to .711mm. Overall lengths produced from 25.4mm to 38mm. Tip sizes range from .001mm to .115mm.
-
product
Gas & Flame Detection System
Syntel
Teledyne Gas & Flame Detection
Syntel is an addressable loop system suitable for use in zone 1 and 2 hazardous areas. The complete addressable loo is fault tolerant operating normally with a short or open circuit. Syntel does not have a CPU, so there is no common failure point. It includes a standard OPC interface and can also be supplied by Modbus allowing easy integration with third party systems.Syntel stores alarm and calibration information in distributed non-volatile memory, hence there is no reliance on a centralized system.Syntel is ideal for installations where there is the possibility for future expansion. The system architecture allows very low cost expansion as cable runs to a central location are not needed.
-
product
Fixed Flame Detectors
Teledyne Gas & Flame Detection
Would you like to source high-performance flame detectors? Teledyne Gas and Flame Detection offers detection solutions that precisely meet the needs of the most demanding professionals.
-
product
Needle Microprobe
MT-26/6HT
Fast-response 26 gauge needle probe, (needle length is 6 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.