Laplace Instruments Ltd.
The Laplace products are designed and manufactured in he UK, we enable manufacturers to reduce the cost of EMC Testing, increase productivity and reduce the product time to market.
- +44 (0) 16 92 40 20 70
- tech@laplace.co.uk
- Tudor House
Grammar School Road
North Walsham, Norfolk NR28 9JH
United Kingdom of Great Britain and Northern Ireland
-
Product
RF Field Probes (LSprobe)
Immunity
-
Your product descThe LSProbe range of laser-powered E-Field probes offers precision, speed, and flexibility for EMC testing environments that demand reliable, uninterrupted measurements. These compact, battery-free probes use a galvanically insulated laser power supply, eliminating downtime and enabling continuous, high-resolution field monitoring with minimal noise and fast pulse response.ription goes here.
-
Product
Antennas
Emissions
-
Laplace offers a Comprehensive range of antennas. These cover all the radiated emissions and immunity test requirements. All antennas are supplied with calibration and AF data.
-
Product
DC Filters
-
This DC filter provides substantial noise reduction on DC power lines of up to 50V 9A. Filter provides noise suppression in both directions protecting your DC lines from noise generating by a particular piece of equipment or protecting your sensitive equipment from noise coming from DC power supply or other loads. DC filter provides noise suppression for both power lines – positive and negative, plus common-mode noise vs. ground. Filter uses plug-in terminal block for connections and mounting flanges for easy installation. Its rugged construction makes it easy to fit in many industrial tools.
-
Product
RF Shield Box
Immunity
-
A small versatile manual shielding box that is designed for small scale device testing such as wireless network cards and wireless communication equipment.
-
Product
Clean Power Source
AC1000A
-
The AC1000 achieves its unique price/performance ratio by actively adjusting the incoming mains waveform to produce a clean output. Other suppliers use convertor techniques to completely recreate the output from scratch. Our solution delivers an output which achieves the required THD with the minimum of hardware and expense. It includes the ability to switch the correction in or out so that the original waveform can be observed and measured if required. Overload and thermal protection systems are built-in and produce an audible warning if activated.
-
Product
Electrostatic Discharge (ESD)
Immunity
-
The sudden, momentary flow of electric current between two objects with different electrical charges.
-
Product
RF Sensors And Probes
Emissions
-
A meter specifically designed for CEMFAW(2016) requirements. This hand held meter covers Electric, Magnetic and RF fields and will display levels vs standard limits. Includes data logging and GPS feature with automatic plotting to maps for area survey
-
Product
Coupling Decoupling Network (CDNE)CDN
Emissions
-
CDNEs are based on the CDN as specified in IEC61000-4-6 (Conducted RF Immunity test). In this test, the CDN is used for the coupling of RF onto a cable. In principle, the CDN can be used in reverse, ie coupling any RF on the cable out to an analyser. In an earlier version of EN 55015, these CDNs were specified as suitable for measuring emissions. However, the current version of the standard specifies a CDNE which is essentially a CDN refined to deliver higher accuracy particularly at higher frequencies.
-
Product
Synthesisers
Immunity
-
The Laplace Synthesisers cover both conducted and radiated RF immunity test requirements. The frequency coverage extends from 100KHz to 500MHz for conducted tests (RFIC-4-6) and 30MHz – 6GHz for radiated tests (RF3000/RF6000). They are all controlled from the users PC via a USB link, and powerful Windows software is included to enable the user to control all the parameters of the test, to monitor the test in progress, and to view the results.
-
Product
RF Sensors & Probes
Immunity
-
A meter specifically designed for CEMFAW(2016) requirements. This hand held meter covers Electric, Magnetic and RF fields and will display levels vs standard limits. Includes data logging and GPS feature with automatic plotting to maps for area survey
-
Product
Pre-Selectors for EMC test
Emissions
-
These Pre-Selectors are high specification, switched band filters which track the scanning of the EMC Analyser. Control is via USB link from the Laplace EMCEngineer software supplied with SA1002 and SA3000 analysers. Installation and operation is completely automatic, and the filters will synchronise with the analyser scan without any operator intervention. A front panel switch allows manual operation if required.
-
Product
Servo And VFD Filters
-
Operation of PWM-driven motors – servo motors and variable frequency drives (VFD) – causes several problems in equipment, including damage to the motor’s bearings due to leakage current causing electrical discharge machining (EDM) and damage to motor’s insulation. PWM motors also are a major source of EMI in equipment. These motor drive systems use pulsed power to drive the motors. As we are aware, the sharp edges of the pulses inevitably include high frequency components which can couple or radiate as noise to other parts of your system and cause unreliability, communication/control problems and EMC compliance issues.
-
Product
Amplifier Systems
RF Amplifiers
-
Systems are complete. They plug into an outlet and are ready to go. Our standard systems are 3U, which is 5.25″ and 5U, 8.75″. Systems are available with or without IEEE-488, RS-232 and Ethernet connectivity. Amplifiers Systems are available in both Broadband and Band-Specific frequencies.
-
Product
Line Impedance Stablisation Networks (LISN)
Emissions
-
All commercial LISNs include an artificial hand connection and a transient limiter. This adds a 30dB insertion loss. A 30dB pre-amplifier is included which can be connected in the RF output feed to return the insertion loss to 0dB. All bar the heavy current LISNs are constructed in a flanged aluminium enclosure that can be bolted directly down to a ground plane (as required by standards). The underside of the enclosure is left unpainted to ensure good conductivity with the plane. The 16A and military/automotive LISNs have an RF output for each line, thus allowing parallel measurements of the emissions. This facilitates measurement of common mode and differential mode components of the emissions if required.
-
Product
Voltage Probes (Power Line Interference Probe)
Emissions
-
The Voltage Probe requirement is covered by our PLIP (Power Line Interference Probe). This fully meets the requirements of CISPR16, but has additional features: Fully galvanic isolation between input and output (>1kV), for the safety of operator and analyser. hrouded safety clips for attachment to the line to be measured. Filtered frequency response matched to Band A and B. Current limiting on the output. Visual indication of high voltage input