EMC Analyser
Emissions
-
Apart from the maximum frequency, these analysers are identical. Both analysers are available with a band A option to cover the range 9KHz-150KHz. They offer the ability to perform pre-compliance testing and compliance measurements. If measuring conducted emissions, use of a pre-selector is recommended owing to the impulsive nature of conducted signals.These analysers are supplied complete with PC software, fully compatible with Windows versions from XP to Win11.
-
Product
Analyser
Harmonics & Flicker
-
The Laplace Harmonics and Flicker analyser provides the user with a complete system for testing product compliance with IEC61000-3-2 and IEC61000-3-3.
-
Product
Synthesisers
Immunity
-
The Laplace Synthesisers cover both conducted and radiated RF immunity test requirements. The frequency coverage extends from 100KHz to 500MHz for conducted tests (RFIC-4-6) and 30MHz – 6GHz for radiated tests (RF3000/RF6000). They are all controlled from the users PC via a USB link, and powerful Windows software is included to enable the user to control all the parameters of the test, to monitor the test in progress, and to view the results.
-
Product
EMI Filters & Adapters
Emissions
-
The commonality in this section is conducted noise. Noise is not just a consideration when complying with EMC legal requirements, its is also potentially damaging and/or cause of failure of product performance or communications, even if the noise level is below EMC standards limits.
-
Product
1GHz EMC Emissions Analyser
SA1002
-
The SA1002 provides a high performance capability to measure the EMC compliance of your products. It covers the conducted emission and radiated emission bands to 1GHz, as required by most EMC standards. The included software is Windows compatible and simple to use. This powerful system automatically sets the analyser parameters to suit the test to be performed. Standard limits are available from simple pull-down menu. Results can be directly compared against these limits for easy checks on compliance status.
-
Product
RF Filters
-
RF Filters block unwanted frequencies when testing electronic devices for emissions during EMC testing. They attenuate unwanted frequencies and allow the desired signals through. The RF filters isolate the device under test from external RF noise, this increases the reliability and accuracy of the EMC testing by preventing out-of-band noise and harmonics.
-
Product
Electrostatic Discharge (ESD)
Immunity
-
The sudden, momentary flow of electric current between two objects with different electrical charges.
-
Product
RF Sensors & Probes
Immunity
-
A meter specifically designed for CEMFAW(2016) requirements. This hand held meter covers Electric, Magnetic and RF fields and will display levels vs standard limits. Includes data logging and GPS feature with automatic plotting to maps for area survey
-
Product
Clean Power Sources
Harmonics & Flicker
-
The AC1000 achieves its unique price/performance ratio by actively adjusting the incoming mains waveform to produce a clean output. Other suppliers use convertor techniques to completely recreate the output from scratch. Our solution delivers an output which achieves the required THD with the minimum of hardware and expense. It includes the ability to switch the correction in or out so that the original waveform can be observed and measured if required. Overload and thermal protection systems are built-in and produce an audible warning if activated.
-
Product
Power Meter (LSPM)
Immunity
-
The LSPM series of RF Power Meters from LUMILOOP provides fast, accurate, and versatile power measurement across a wide frequency range. Designed for high-resolution time-domain analysis, pulse characterisation, and seamless integration with EMC test systems, these meters are ideal for modern labs requiring reliable RF power monitoring across multiple channels and applications.
-
Product
Amplifier Systems
RF Amplifiers
-
Systems are complete. They plug into an outlet and are ready to go. Our standard systems are 3U, which is 5.25″ and 5U, 8.75″. Systems are available with or without IEEE-488, RS-232 and Ethernet connectivity. Amplifiers Systems are available in both Broadband and Band-Specific frequencies.
-
Product
3GHz EMC emissions Analyser
SA3000
-
The SA3000 is a powerful, fully featured, EMC analyser. It will measure both conducted and radiated emissions according to the international EMC standards. It enables the user to assess the EMC compliance of products quickly and with good integrity.
-
Product
Voltage Probes (Power Line Interference Probe)
Emissions
-
The Voltage Probe requirement is covered by our PLIP (Power Line Interference Probe). This fully meets the requirements of CISPR16, but has additional features: Fully galvanic isolation between input and output (>1kV), for the safety of operator and analyser. hrouded safety clips for attachment to the line to be measured. Filtered frequency response matched to Band A and B. Current limiting on the output. Visual indication of high voltage input
-
Product
Pre-Selectors for EMC test
Emissions
-
These Pre-Selectors are high specification, switched band filters which track the scanning of the EMC Analyser. Control is via USB link from the Laplace EMCEngineer software supplied with SA1002 and SA3000 analysers. Installation and operation is completely automatic, and the filters will synchronise with the analyser scan without any operator intervention. A front panel switch allows manual operation if required.
-
Product
Coupling Decoupling Network (CDNE)CDN
Emissions
-
CDNEs are based on the CDN as specified in IEC61000-4-6 (Conducted RF Immunity test). In this test, the CDN is used for the coupling of RF onto a cable. In principle, the CDN can be used in reverse, ie coupling any RF on the cable out to an analyser. In an earlier version of EN 55015, these CDNs were specified as suitable for measuring emissions. However, the current version of the standard specifies a CDNE which is essentially a CDN refined to deliver higher accuracy particularly at higher frequencies.