Lisun Electronics Inc.
Lisun Electronics Inc was found by Lisun Group in 2003. We have sales & service offices in Shanghai, Russia, India and Korea. In 2012, we built a high level products show room & lab center in Shanghai. Lisun Group has set up a new manufactory in China to research and develop the world high-technology CFL & LED Test Instruments. Its quality system has been strictly certified by ISO9001:2008. The Lisun Group products have been authenticated by the third party lab and were awarded by CE certificate. As a CIE Supportive Member, all of the test instruments produced by Lisun Group are designed according to CIE Standards.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
-
product
Rotation Luminaire Goniospectroradiometer
LSG-1800CCD
LSG-1800CCD/LSG-1700CCD Goniospectroradiometer is an automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800CCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
Electronic Ballast Tester
LCD for displaying waveforms and parameters directly, and it includes all the functions and technical parameters of WT3000. Reports can be printed if printer is connected. It also meets the latest requirements for electronic ballasts in international standards
-
product
Pocket Illuminance Meter
PHOTO-100
This Pocket Illuminance Meter has performance of high precision, low consumption, small volume, stable performance and convenience operation. It’s mainly used in industrial field for illumination photometry.
-
product
Output Characteristic Analyzer of Electronic Ballast
UI2002
• Measure lamp voltage, lamp current, lamp power, oscillatory frequency, filament current, guided cathode current, and crest factors • Measure changing curves and values of startup lamp voltage, lamp current, filament current, cathode current from 0 to 5 seconds, as well as the pre-heat time • Accuracy: Class 2 • Data and curves printable. All the data and curves can be displayed after being connected with PC
-
product
HVR-LS Horizontal Vertical Flame Tester
HVR-LS/HVR-LSS
This equipment meets the requirements of ANSI/UL94, IEC60950-1, IEC695-2-2 and GB Standard. It is used to test the appliances and plastic materials parts of electrical equipment for the horizontal, vertical flammability test. The product tank shell is irony spray, and configured a transparent viewing window, the digital meter shows the burning time, afterflame time, afterglow time, this device has beautiful appearance, is easy to use and has reliable performance.
-
product
Compact Goniophotometer
LSG-1200A
The compact goniophotometer of LSG-1200A is used to measure the luminous intensity distribution curve, intensity data, spread angle and other parameters for Chip LED, LED Module, LED Spotlight and all other light which beam angle is no more than 180 degree. • Meets the requirements of IEC, CIE and LM-79 standards • Measures beam angle automatically: staple half intensity angle as well as 1/4 intensity angle, 3/4 intensity angle and 1/10 intensity angle which meets the special requirements. • Measured data is matched with international standard form (IES) and can be applied for lighting design by other lighting design software such as DiaLux • LSG-1200A has included a dark room, measures the maximum size of lamps: 180mm • Test range of luminosity: 0.1~30,000lx. Test accuracy of detector: Class 1 • The distance between the tested lamp and detector is 316mm/1000mm • Angle interval: Horizontal angle: 1°/5°/10°/15°/22.5°/30°/45°/90°, Vertical angle: 0.5°/2°/1.5° • The LSG-1200A horizontal automatic rotating on 0°~360° and Vertical automatic rotating on -90°~+90° • Test accuracy of angle: ±0.2° Work with the follow instruments as a System
-
product
Auxiliary Lamp
RLS-50W
Due to the luminaries self-absorption, the auxiliary lamp is used to correct the flux test value. Work with the follow instruments as a System
-
product
Masks Respiratory Resistance Tester
WKS-1200
WKS-1200 Masks Respiratory Resistance Tester applies to determining the inhalation resistance and exhalation resistance of respirators and mask protective products under specified conditions, and used for the relevant testing and inspection of ordinary mask products by the national labor protection equipment inspection agency or manufacturer.
-
product
Electrostatic Discharge Simulator
ESD61000-2
ESD simulator (Electrostatic Discharge Generator or Electrostatic Gun) is in full compliance with IEC 61000-4-2, EN61000-4-2, ISO10605, GB/T17626.2, GB/T17215.301 and GB/T17215.322. The ESD generator is designed for the assessment of electrical and electronic equipment to withstand ESD performance. ESD61000-2/ESD61000-2A has LCD display in both English and Chinese, they equipped with an infrared remote control which can allow you do the test in some special place.
-
product
Optical Path Converter
LS512A/LS512B
There are many LED manufactories using two integrating spheres and one spectrophotometer to do test. The previous testing way is: when you use big sphere to test, the customer need to connect the detector cable and optical fiber from the Spectrophotometer to the big sphere, after the calibrating and then you can do the test. When you use the small sphere, you need to take away the detector cable and optical fiber from the big sphere to the small sphere, then need to calibrate again. It is too troublesome to take out the detector cable and optical fiber between the big sphere and small sphere, and you need to calibrate again for every change. The frequent change will also shorten the life of the detector cable and optical fiber.
-
product
2D Video Luminance Meter
LS-ELF
LS-ELF can record 15 frame’s 2D luminance data per second. Also LS-ELF can record the image while driving 60-80km/h speed. It can be used in many fields as Display, Light pollution, Lighting, Lab, etc.
-
product
Integrating Sphere with Side Assistant Opening
IS-*MA**P/IS-*MA**C
According to IES LM-79 Clause 9.1.2, it request the 4π geometry configuration and 2π geometry Integrating Sphere for the LED Testing. Lisun Group developed the integrating sphere with side assistant Opening in A Molding Technology to meet the requirements.• Painting material of integrating spheres is according to CIE Pub.No.84 (1989) • The painting material is BaSO4 coating: ρ (λ) ≥0.96 (450nm~800nm) and ρ (λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectance ρ≈0.8 and accuracy of ρ (λ) <1.5% • Build-in all functional lamp testing jigs: the vertical is for E40/E27, the horizontal is for T5/T8/T12 tubes and the Testing Holder Base for LED street luminiares. All of the testing jigs can allow the lamp be tested up and down in the sphere. • Power Cable, Power Terminal and Auxiliary lamp position has been built-in (Auxiliary lamp is option). • Two photo detector ports, one optical fiber port and temperature sensor hole are built-in • Ordering Code: IS-1.5MA55P or IS-1.5MA55C (Φ1.5m, IS-1.5MA55P means square side opening is 0.5×0.5m, IS-1.5MA55C means cycle side opening diameter is 0.5m). IS-1.75MA66P or IS-1.75M66C (Φ1.75m and side opening is 0.6m). IS-2.0MA77P or IS-2.0MA77C (Φ2.0m and side opening is 0.7m). • Other size such as diameter 2.5m, 3.0m can be special order according to customer’s request
-
product
Multiway Life Tester
CH316
• Measure 16 samples at the same time, evaluate and record the life of each sample. • Very flexible: Samples can be added and changed at anytime. • The life of each sample is readable at anytime. • The switch ON/OFF time is adjustable (Test period is min 1s). • Automatically remember the test result when the power is off, and resume the old measurement when power is on. • Sound and light alarm when the products were failed.
-
product
Integrating Sphere
The standard test temperature is 25, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
product
Mask ventilation resistance and pressure differential tester
WKS-3102
Mask ventilation resistance and pressure differential tester is used to measure the inhalation and exhalation resistance of mask under specified conditions. Applicable to mask manufacturers, labor protection equipment inspection agencies to carry out related testing and inspection of mask products, mask breath resistance tester, breathing valve air tightness tester, breath resistance machine for measuring respirator and mask protection products in Inspiratory resistance and expiratory resistance under specified conditions.