Product
Wire Damaged Tester
WDT-1
-
This equipment is designed and manufactured according to corresponding regulation in standard IEC884-1, GB299.1-96, GB16915.1-97 and other electronic accessories relevant standard. Mainly used to test damage degree of fixed connection components lead wire of with thread clamping type and no screw terminals, so as to inspect whether it can withstand mechanical stress during normal use.Specification: • Power supply: AC220V 50Hz • Test rate: 10±2r/min (GB16915.1-97: 12 ±1r/min) • Rotating radius: 100mm • Test distance: 250~500mm adjustable • Test numbers (Number of rotating): 0~999999 any set • Mass: 0.3KG, 0.4KG, 0.7KG, 0.9KG, 1.4KG, and 2.0KG (GB16915.1-97: 30N, 40N, 50N, 60N each of 2 pcs) • Stations: 2 • Dimension: 1200×1400×400 (mm) • Remarks: The mass and rotating radius can be optional as per customer requirements.
-
Product
HVR-LS Horizontal Vertical Flame Tester
HVR-LS/HVR-LSS
-
This equipment meets the requirements of ANSI/UL94, IEC60950-1, IEC695-2-2 and GB Standard. It is used to test the appliances and plastic materials parts of electrical equipment for the horizontal, vertical flammability test. The product tank shell is irony spray, and configured a transparent viewing window, the digital meter shows the burning time, afterflame time, afterglow time, this device has beautiful appearance, is easy to use and has reliable performance.
-
Product
RF Conducted Immunity Test System
RFCI61000-4-6
-
RFCI61000-4-6 RF Conducted Immunity Test System is an automatic test system which is for the conduction sensitivity testing, it is fully meets IEC61000-4-6.2006, ISO11452-4, GB/T17626.6-2008 and GTB152B-CS114 etc standards. RFCI61000-4-6 internal source and broadband power amplifier can be generated 3 voltage test levels: 1v, 3v and 10v, and has the function of the real detect output level. It has two operation software which is calibration software and test software. When measuring, the signal is in 1 KHZ sine wave amplitude modulation system (80%) to simulate the actual harassment, and can through the coupling/decoupling network (CDN or electromagnetic clamp) to make the harassment signal coupled to the device.
-
Product
Digital Power Meter (AC & DC Model)
LS2012
-
• Measure Vrms, lrms, W, PF/Hz; • Measure AC, DC, AC+DC; • Automatic selecting, out of limit alarming, advance the work efficiency; • Voltage range: AC: 5-600V, DC: 1-600V. Current range: AC&DC: 0.005-20A with high measure accuracy. Auto range; • Accuracy: ± (0.4%reading + 0.1%range + 1digit).
-
Product
LED Luminous Intensity Distribution Tester
LS860
-
LS860 Luminous Intensity Distribution Tester is a precise electronic instrument for measuring LED luminous intensity. It’s strictly designed according to LED standard requirements of CIE 127-1997 A or B Condition.
-
Product
Photometer and Colorimeter
-
Illuminance (lux), CCT, Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram
-
Product
HCAI-1 High Current Arc Ignition Tester
HCAI-1
-
The HCAI-1 High Current Arc Ignition Tester is according to IEC 60950-1:2001, BS EN 60950-1:2001, BS 7002:2000, GB 4943.1-2011
and UL746A, IEC60947.1: 1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-2008 and other standards required simulated safety test project. Parts and components of insulating materials or other solid combustible materials that are prone to flame spread in electrical and electronic equipment may ignite due to proximity or contact with electric arc, causing electrical fire and endangering the reliable operation of equipment and personal safety. -
Product
ZY-3 Needle Flame Test
ZY-3/ZY-3S
-
According to IEC60695-2-2 and IEC60695-11-5, ZY-3/ZY-3S Needle Flame Test is applied in the production and quality control department of lighting instrument, hyperpiesia electrical apparatus, domestic appliance, machine electric appliance, electrical machine, power tool, electronic instrument, electrician instrument and technical equipment. Also, it is fit for the industry of insulation material, engineering plastics and solid combustible material.
-
Product
Spectroradiometer
-
Spectroradiometer is usually used with a integrating sphere to measure the photometric and colorimetric parameters of all kinds of lamps. Relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature Tc, color rendering index Ra, dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, SDCM, luminous flux, etc.
-
Product
Optical Radiation Safety Test
EN62471-C
-
IEC62471-2006(CIE S009) Photobiological Safety of Lamps and Lamp System and IEC TR62471-2(2009) Guidance on Manufacturing Requirements Relating to Non-laser Optical Radiation Safety have be published addressing hazard to human (mostly eye and skin), and are completely suitable to assess the optical radiation safety of non-laser sources, such as LED products, UV radiation in general lighting products and etc.
-
Product
High and Low Temperature & Low Pressure Chamber
LAP-100
-
It is according to GB10590 / GB15091 low temperature / low pressure test chamber requirements; GB11159 low pressure test chamber requirements; GB / T2423. 25-1992 low temperature / low pressure integrated chamber requirement; GB / T2423. 26-1992 High temperature / low pressure integrated chamber requirement; GJB150. 2-86 low temperature / low pressure test etc standards. It’s used to test the In aviation, aerospace, information, electronics and other fields, to determine the instrumentation, Electrical products, materials, components, equipment etc.
-
Product
Three Loop Antenna
VVLA-30M
-
The three loop antenna VVLA-30M is a standard measurement antenna according to CISPR15-2005/GB17743-2007 standard
, it can work with LISUN EMI-9KA / EMI- 9KB EMI Receiver System for EUT magnetic field radiation measurement between X, Y and Z planes. The antenna measurement is accurate, switch conveniently and it can completely replace imported products. -
Product
Face Masks Particulate Filtration Efficiency PFE Tester
GLE-20
-
GLE-20 is an oil-salt two-in-one Face Masks Particulate Filtration Efficiency PFE Tester. According to ASTM F1862-17, ASTM F2299-03 (2017), ASTM F2100-2019, BS EN14683-2019, BS EN 14387-2004+A1 2008, BS EN 136-1998, BS EN 140-1999, BS EN 143-2000 +C1-A1, BS EN 149-2001+A1, etc. It is used to test the particulate filtering efficiency of daily protective masks and medical masks, and to determine the obstruction performance of ordinary fabrics and medical protective masks against a constant flow of airflow.
-
Product
Load Cabinet
DFX-20
-
• Working power: AC220V 50Hz • Normal load: Continuous adjustable from 0 to 280V • Electric current: 0~20A/Continuos adjustable cosφ: 0.3-0.96 under 16A; 0.6~0.96 more than 16A • Precision: 0.5 class, digital display • Counter: 0~999999 times, can be preset
-
Product
AC/DC Withstand Voltage Test
WB2671A/WB2671B
-