Filter Results By:
Products
Applications
Manufacturers
-
product
Shunt Voltage References
Analog Devices offers a broad line of shunt precision voltage references that combine excellent accuracy and temperature stability with low noise and small packages. These devices operate in a manner that is functionally equivalent to a Zener diode. The bias current must be set higher than the sum of the maximum quiescent current of the voltage reference and the maximum expected load current. Since shunt voltage references are typically biased with a resistor, the voltage reference can operate on a wide range of input voltages.
-
product
Ultra-Low Noise, Precision Voltage Reference
ISL21090
The ISL21090 is an ultra-low noise, high DC accuracy precision voltage reference with a wide input voltage range. The ISL21090 uses Renesas' advanced bipolar technology to achieve sub 1.0µVP-P (1.25V option) 0.1Hz to 10Hz noise with an initial voltage accuracy of 0.02% (2.5V option).
-
product
Digital Tank Test Kit
4109
The voltmeter included in the kit, the “Model DPM” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers two ranges, ±2VDC and ±20VDC with a 20MΩ input impedance. Since the voltmeter is digital [in contrast to the meter in our analog tank test kit (Cat. # 4108)], both negative and positive voltages are displayed. `
-
product
2 Channels, 28-115 Vrms, 47 Hz-2.5 kHz (max. range) programmable
AC3
The module is used to provide an AC signal source when a secondary reference source other than the optional on-board reference module is required. The modules are programmable for full range voltage outputs from 2 to 115 VAC, and frequency from 47 Hz to 10 kHz.
-
product
VME Analog Output Module
DP-VME-2115
DP-VME-2115 is an industrial standard 24 channel D/A (Digital to Analog) board. It incorporates most of the features which are demanded in industrial applications. Each Digital to Analog Converter (DAC) is provided with a separate reference voltage selection either from internally generated reference or from the external input. This external input reference signal is passed into the protection circuits before it is fed to any active components. The input protection circuit is designed for ± 25Vp-p input ranges. The DAC output may be unipolar or bipolar and the output is jumper selectable, which is routed to the VME P2 connector, with short circuit protection of upto 30mA.
-
product
Precision High Voltage Meter
Precision High Voltage Meter offers the highest level of measurement accuracy, yet with its color touch screen – is surprisingly easy to use. Vitrek leverages DSP technology to provide outstanding AC &DC voltage measurement accuracy, stability, repeatability and resolution. The 4700 High Voltage Meter offers performance that rivals traditional high voltage reference dividers – yet unlike the tedious divider, the 4700 provides instant, direct, high voltage measurements in a highly portable, compact and rugged bench top enclosure.
-
product
Reference Measuring System
SMG-R
Reference peak voltage meter SMG-R for precise measurement of high voltage. This PEAK voltmeter has higher accuracy and the measuring divider has a very high stability.
-
product
DC Power Supplies
Is the unidirectional flow or movement of electric charge carriers (which are usually electrons). The intensity of the current can vary with time, but the general direction of movement stays the same at all times. As an adjective, the term DC is used in reference to voltage whose polarity never reverses.
-
product
Thermocouple Kit
34307A
The Keysight 34307A is compatible with the Keysight 34970A Data Acquistion/Switch Unit. The 34307A can also be used with the Keysight 34401A, 34460A or 34461A, however, an external program is required to convert the voltage measurements to temperature and an ice bath or electronic reference junction must be used.
-
product
Self Powered Active Load
TBOH02
The TBOH02 is a self powered, precision active load. It does not need a separate supply voltage and operates as low as 2V. Its features include constant resistance and constant current mode. A 10 turn potentiometer with dial, a range switch and a precision reference enable accurate setting of current or resistance. Furthermore it can be controlled by an external voltage.
-
product
5VA Reference Supply, DC input
PS5410C-16
The PS5410C-16 is a 5VA AC Reference Power Supply, available with many transformer isolated output voltages at different frequencies. Input power is either 12 VDC or 15 VDC. The standard 15 pin "D" connector simplifies interconnection to other equipment.
-
product
Current Sensing
voltage-output, current-sensing amplifier family that integrates an internal shunt resistor to enable high-accuracy current measurements at common-mode voltages that can vary from 0 V to 36 V, independent of the supply voltage. The device is a bidirectional, low- or high-side current-shunt monitor that allows an external reference to be used to measure current flowing in both directions through the internal current-sensing resistor sensor. The integration of the precision current-sensing resistor provides calibration equivalent measurement accuracy with ultra-low temperature drift performance and ensures an optimized Kelvin layout for the sensing resistor is always obtained.
-
product
Reference Voltage Measurement Cell
C-80
Cells C-80 and C-100 are used as reference devices for measuring voltage during calibration and adjustment of OLT-series testers.
-
product
2 Channels, 2-28 Vrms, 47 Hz-20 kHz (max. range), programmable
AC2
The module is used to provide an AC signal source when a secondary reference source other than the optional on-board reference module is required. The modules are programmable for full range voltage outputs from 2 to 115 VAC, and frequency from 47 Hz to 10 kHz.
-
product
IP67 DC Blocking Splitter Combiner
PD5043
INSTOCK Wireless Components, Inc
PD5043 is an IP67 outdoor, weather resistant, DC blocking, four way, RF broadband, 50 ohm, power divider, power combiner furnished with N type coaxial connectors. The passive Wilkinson design passes RF and the 10 MHz reference signal through both ports while blocking DC current. This configuration is typically used in combining applications to prevent passing DC to the sum and adjacent ports. Max voltage rating at the DC blocked ports is 50 VDC. All wireless band applications in the frequency range from 698 to 2700 MHz are covered with best in class RF performance. The RoHS compliant PD5043 is a bidirectional device capable of 40 W max microwave input power levels in both power splitter and combiner apps. See 4 way power divider input rating tables for additional power handling info.
-
product
Rad-Hard Analog ICs
ST's wide range of rad-hard QML-V qualified analog ICs covers analog-to-digital converters (ADC) and digital-to-analog converters (DAC) for telemetry, instrumentation and imaging applications. Our portfolio also includes rad-hard op amps, high-speed differential amplifiers up to 1 GHz, shunt voltage references and comparators to ensure a complete solution for signal conditioning, referencing and data conversion.
-
product
1000W Ferroresonant Power Supply
Series PRR
Kepco's PRR are 1000 Watt rack mounted laboratory systems power supplies that offer the low cost and very high dependability of ferroresonant voltage stabilization.The ferroresonant stabilizing technique provides extraordinary isolation from a wide variety of source noise. It is inherently short-circuit proof and cannot expose delicate loads to overvoltage hazards. Hence no crowbar, fuses, or bounding circuits are needed. Ferroresonant power supplies use no noise-producing switches or oscillators. Voltage setting is independent of delicate control settings or diode references and requires no comparators, references, or limiters. Efficiency is 70-80%.
-
product
PWM to Voltage Output D/A Converters
Analog Devices’ pulse-width modulation (PWM) to voltage output D/A converters convert a PWM input to an accurate, stable, buffered voltage without the ripple, slow settling, and external passive components of discrete filter implementations. Our PWM D/A converters measure the period and pulse width of a PWM input signal and immediately update the D/A converter output with up to 12-bit accuracy and no software coding required. This family of D/A converters is available with 8-bit to 12-bit resolution, dual and quad channels, integrated references, and with high temperature operation. Applications include isolated motor control, automotive headlights or industrial lighting, and other applications that benefit from the simple control interface.
-
product
Single Phase Reference Standard Meter
Signals & Systems India Private Limited
The Single Phase Portable Reference Standard (SPRS-1102) from SANDS is a portable meter test equipment that helps to calibrate the error present in the single-phase energy meter i.e. the meter under test (MUT). The SPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, phase angle etc of the meter under test. It has an LCD display and an alphanumeric keypad to suit the user. It can be interfaced with the PC for analysis. It has the capability of storing 1000 test results.
-
product
Linear IC Tester
570A
The Model 570A Analog IC Tester's built-in test library includes all common Analog ICs including op-amps, comparators, voltage regulators, voltage references, analog switches & multiplexes, opto-isolators & couplers, and audio ICs.
-
product
Three-phase Fully Automatic Test System
TS41
Calmet Smart Calibration Devices
The Calmet TS41 test system consists of a three-phase reference meter of accuracy class 0.02% (or 0.04%) and an integrated three-phase current and voltage source up to 3x120A/600V. It makes possible automatic testing of electricity meters in meter test stations
-
product
20 Bit Dual-Channel Reference Source
DRS20
The DRS20 is a dual-channel reference source offering ultra high precision and stability and provides a +/-10 V output. The output current can be up to 10 mA and the 4 wire connection provides a 1 µV/mA load regulation. The high precision and stability is achieved by using a temperature controlled voltage reference.
-
product
Instrumentation Amplifiers
Analog Devices instrumentation amplifiers (in-amps) are precision gain blocks that have a differential input and an output that may be differential or single-ended with respect to a reference terminal. These devices amplify the difference between two input signal voltages while rejecting any signals that are common to both inputs. The in-amps are widely used in many industrial, measurement, data acquisition, and medical applications where dc precision and gain accuracy must be maintained within a noisy environment, and where large common-mode signals (usually at the ac power line frequency) are present.
-
product
High Speed Response, High Accuracy DC Leakage Current Sensor
DCZCT-20CDHL
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Low DC current measurements.*DC1mA~200mA*High accuracy.*±1%F.S ±10mV*Least influence of magnetization.*Less than DC1mA in current level*Convenient +5V single polarity power supply.*Reference voltage (Vref) terminal is equipped.
-
product
Software
Junction Measurement and Analysis
Materials Development Corporation
A comprehensive set of analyses for junction diode or Schottky barriers begins with C-V data gathering that adjusts the voltage step to the slope of the C-V characteristics. This assures an optimum set of C-Vdata whether the voltage range is small or large. Doping profile and resistivity profile are both available at the touch of a key. Plots of 1/C2 - V or Log(C) - Log (V+ phi) show doping uniformity and doping slope factor. Exclusive recalculation options allow adjustment of stray capacitance and area to facilitate calibration using a standard reference wafer of known doping or resistivity.
-
product
Signal Conditioners
General Purpose
Encore offers a complete line of General Purpose Signal Conditioning instrumentation to meet even the most demanding requirements. Packaged as interchangeable two-channel plug-in modules, Encore’s broad product line includes frequency to voltage converters, strain gage amplifiers, accelerometer conditioners, digital voltmeters and DC power supplies. All of our systems feature a common CAL input on the rear of the rack which allows for calibration of the entire rack. Calibration function varies based on the modules installed. For example, the Model 633 applies a shunt calibration resistor across the bridge, while the Model 149 applies a reference charge source to the input. Contact Encore today and let our team of design engineers help you determine which of our products is best for your application.
-
product
IP67 DC Blocking Splitter Combiner
PD5033
INSTOCK Wireless Components, Inc
PD5033 is an IP67 outdoor, weather resistant, DC blocking, three way, RF broadband, 50 ohm, power divider, power combiner furnished with N type coaxial connectors. The passive Wilkinson design passes RF and the 10 MHz reference signal through both ports while blocking DC current. This configuration is typically used in combining applications to prevent passing DC to the sum and adjacent ports. Max voltage rating at the DC blocked ports is 50 VDC. All wireless band applications in the frequency range from 698 to 2700 MHz are covered with best in class RF performance. The RoHS compliant PD5033 is a bidirectional device capable of 40 W max microwave input power levels in both power splitter and combiner apps. See 3 way power divider input rating tables for additional power handling info.
-
product
Microvolt DC Volt Meter
QA350
The QA350 relies on a built-in reference to calibrate the ratio between the hi and low ranges. If you have a preferred lab reference, you may use that it to improve the QA350 accuracy beyond the indicated +/- 400 PPM. For example, various vendors on eBay can provide calibrated +/-30 PPM 5 or 10V voltage references that can be used to set the ultimate accuracy of the QA350 to under 50 PPM at room temperature.
-
product
Signal Analysis
Harmonic Distortion Analysis
The software is used for automatic measurement of the harmonic distortion factor and voltage r.m.s. of signals coming to the input channels of FFT spectrum analyzers. Adjustment to the frequency of the main component is performed automatically. The program is based on the measurement of the voltage r.m.s. of higher components by an external or internal reference signal.
-
product
Digital Multimeters
Multi-Display : Primary 80000, Secondary 80000, Bargraph 23 SegmentsBasic DC Accuracy : 0.05% mV Impedence : > 1000M OhmMore than 50 Measuring FunctionsFrequency Measurement : 0.5Hz to 8.0000MHz 16 Frequency Points, 1% to 99% Duty. Selectable Square Wave OutputAnalyzing Component of Current or Voltage SignalResistance : 0.1Ω to 80MΩ, 10MΩ to 8000MΩCapacitance : 1nF to 100µFTemperature : -50°C to 1372°C, -58°F to 2502°F dBm 20 Types of Reference ImpedenceAuto Data Hold / Peak HoldRelative Measurement36 Hours Dynamic Recording : MAX / MIN / AVG/ MAX-MINCommunication : Isolated Optical RS-232Timer for MeasurementBacklight DisplayAuto Power Off