Verband der Elektrotechnik
-
product
Earth Resistance Tester
PeakTech Prüf- und Messtechnik GmbH
A Rugged sealed digital earth tester is built with all the protection you need for outdoor use. The instrument is suitable for the testing of single earth electrodes such as lightning conductors and other small earthing systems according to VDE 0413. The resistance of conductors such as continuity and conduit coupling joints can also be measured. Two-terminal operation measurement, which reduces the accuracy, can also be done by shorting P and C terminals. It has an advanced circuit design that permits the instrument to operate with the minimum influence from earth voltage and earth resistance of the auxiliary spikes.
-
product
KPG 24kV VLF Test Set
Kilovolt Prueftechnik Chemnitz GmbH
The portable cable test set KPG 24kV VLF is used for testing of medium voltage cables in accordance to the standards IEC 60502-2, CENELEC HD 620 & 621, DIN VDE 0276/620 & 621 and IEEE 400.Test is carried out with a low strain practice with VLF (very low frequency) test voltage of preferably 0.1Hz.VLF testing enables detection of damages of insulation within shortest test time.
-
product
Earth Meter
EM-4055
The EM-4055 Earth Meter is a digital, microprocessor-controlled instrument that allows to measure the earth resistance and ground resistivity (using Wenner´s method), as well as to detect parasitic voltages present in the ground. This instrument is well suitable to measure earth systems in power substations, industries, distribution networks, etc., according to VDE 0413. It is also suitable for soil resistivity measurements, in order to optimize the earth systems project
-
product
5 kV AC Hipot Testers
Models M100BVS5 & M500BVS5
Now you can perform safe, rapid and efficient hipot testing, ground continuity testing, and total or real current monitoring in one simple operation. The ROD-L Electronics model M100BVS5 and model M500BVS5 hipot testers perform safe and accurate AC hipot and ground continuity testing in compliance with UL, IEC, CSA, VDE, FCC and other electrical equipment testing standards
-
product
PCI Bus Analog Output Board, 4 Isolated Outputs, 14 Bit
APCI-3501-4
4 analog output channels Optical isolation 500 V Settling time 30 µs typ. 14-bit resolution (13 bit for 0-10 V) Output voltage: ±10 V, 0-10 V (switchable through software) Output voltage after reset: 0 V Each output channel has its own ground line (without optical isolation from the others) Driver capacity: 5 mA/500 pF Short-circuit protection, EMI filters Noise neutralization of the PC supply Creeping distance: 3.2 mm acc. to DIN VDE 0411-100 Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary2 digital input channels, 24 V, isolated 2 digital output channels, 24 V, isolated Noise immunity Test level: ESD: 4 kV Fields: 10 V/m Burst: 4 kV Cond. radio interferences: 10 V
-
product
Electrical Safety Testers- Hipots
Safety testers (also named hi-pot tester/hipot tester/hipot test) are designed to ensure safe operation of DUTs under various operating conditions and environment.GW Instek’s GPT-9900/GPT-9800/9600 series safety testers(hipot test) provide safe and quick measurement tools for AC/DC withstanding voltage tests, insulation resistance tests, and AC ground bond tests. Those tests are required by many international safety regulations such as CE, UL, VDE, and etc. We also have leakage current tester, GLC-9000, which supports all the major leakage current test standards for medical and general electronic equipment.
-
product
IEC60335 Inclined Plane Test Table for Stability Test
CX-W600
Shenzhen Chuangxin Instruments Co., Ltd.
It's to determine the stability of electric appliances which are used on a table or on the floorin accordance with IEC 60065 / 1998-07 clause 19.1, IEC 60335-1 / 1991-04 clause 20.1, IEC 60601-1 /1988 clause 24.1, IEC 60950 / 1991 + Amendments, modified, clause 4.1.1,EN 60335-1 / 1994 and A11 / 1995 clause 20.1, EN 60950 / 1992 + Amendments up to 1997 clause 4.1.1,VDE 0700 Part 1 / 10.95 clause 20.1 and Part 3 / 3.96 clause 20.1, VDE 0730 Part 1 / 3.72 clause 20a,VDE 0805 / 11.97 clause 4.1.1Inclined Plane Device is used to test the stability of an apparatus that requires a surface in order to work.The device cosist of a surface and an angle adjusting device with 0- 15 °
-
product
Single, Double Power Cord Tester
LX-30A+
Shenzhen Lian Xin Technology Co., Ltd.
Meet UL, VDE, CSA, SAA, T-MARK, KS. IRAM, CCC and other countries’ standards ..·used to test single – ends ,double –ends ,three-ends power supply cords..·Auto and continuous test in COND,Insulation Resistance ,Leakage Current, Line-to-line Hi-pot(inside HV), Leaking copper(outside HV), relative length,.·Auto test the fine and detective goods, tested qualified ones can be be ejected by ejector pin and marked , automatic cutting defective products, and alarmed with voice prompt and light,
-
product
Partial Discharge Test System
TPP
The Partial Discharge Test System type TPP is used for non-destructive insulation and quality testing of electrical components (for example according VDE 0110-1, EN 50178, IEC 60270 and IEC 60060).
-
product
High Voltage
Accurate measurement of high voltages acc. to VDE 0432 und IEC 60060 in conjunction with a high voltage divider.For the measurement, the principle of capacitive or resistive divider is used, which can be selected in the peak voltage meter.
-
product
Design & Manufacturing Services
Since its inception, APLAB has been serving the Global Market with a wide range of Electronic Products meeting the International standards for safety and reliability such as UL, VDE, etc. APLAB enjoys worldwide recognition for the quality of its products, our business integrity and innovative engineering skills.
-
product
General Power Relays
Panasonic Industrial Devices Sales Company of America
2A and greater load rating in Polarized, Non-Polarized, High Capacity DC, General Purpose, and Safety configurations. UL, CSA, C-UL, TUV, VDE, and SEMKO certifications.
-
product
Insulation Measuring Device According to DIN EN 61557-2 (VDE 0413-2)
PeakTech Prüf- und Messtechnik GmbH
This digital insulation measuring device is required for various measurements of cables, components and their insulation.
-
product
Partial Discharge Meter
TMG
The partial discharge meter TMG was developed for Partial Discharge tests according to VDE 0434 and IEC 60270.
-
product
Power Frequency Transducer
PP1S
1. Measuring and conversion IEC 6882. Dielectrical strength IEC 688 4 KVac / 1 min.3. Impulse test ANSI C37.90 / 1989 IEC 255-3 5KV ( 1.2 x 50 us ) 3KA ( 8 x 20 us ) - current coil4. Surge test (ring wave) ANSI C37.90 / 1989 ( 3KV - 0.5us / 100KHz ) IEC 255-3 ( 2.5KV - 0.25ms / 1MHz )5. Adaptability for power system VDE 0110 6. Measuring reliability VDE 3540
-
product
Power Line Purpose Tester
LX-221A+
Shenzhen Lian Xin Technology Co., Ltd.
·Meet UL, VDE, CSA, SAA, T-MARK, KS. IRAM, CCC and other countries’ standards .·Used to test single – ends ,double –ends ,three-ends power supply cords.·Auto and continuous test in COND,Insulation Resistance ,Leakage Current, Line-to-line Hi-pot(inside HV), Leaking copper(outside HV), relative length,·Auto test the fine and detective goods, tested qualified ones can be be ejected by ejector pin and marked , automatic cutting defective products, and alarmed with voice prompt and light,·Provide with RS 232 interfaces, can communicate with PC, easy to upgrade,·Provide personalized customization according to different requirements.
-
product
Valve Position Sensors
*Dual inductive sensor for pneumatic actuators and valves*Designed for simple fit to common actuators based on VDI / VDE 3845*Quick and easy installation of the AS-i dual sensor*Position feedback for rising stem valves with up to 80 mm stroke*Reliable permanent valve monitoring
-
product
Insulation Meters
Here you will find an insulation tester for a variety of ranges between 50 mega ohms and 2000 mega ohms. The portable manual insulation tester is used for determining insulation resistance, continuous current, alternating current and testing. With an insulation tester, measurements can be taken for different voltages, beginning with 100V up to 10,000V. Measurements meet the DIN VDE 0413 part 1 standard. The insulation tester comes with a test mechanism, clips, batteries and a carrying case. The insulation meter can be equipped for test laboratories if an optional DIN EN ISO is acquired.Measurement of insulation in cables and motor coils is vitally important for the prevention of accidents and damage to installations and is obligatory according to most codes of conduct.
-
product
[5kV AC] Hipot Tester, Rise/Fall-Time Control Function Equipped
TOS5200
TOS5200 is designed for AC Hipot Test with 500 VA capacity and 200 mA short circuit current output capability. Equipped with the PWM amplifier, the TOS5200 can provide a stable & reliable output without being affected by ACpower line. Therefore, it is a perfect solution for electronic equipment or devices complied to IEC, EN, UL, VDE andJIS etc. requirement.As TOS5200 covers most of features of our upper class model for AC Hipot Test, it achieves thesuperb cost / performance ratio for those who need 200 VA or 500 VA capacity, or both. Also, as it equips the Interlockfunction together with other safety features, operator can carry out the test with higher current value in safe.
-
product
Installation Testers
Offers two models that verify the safety of electrical installations in residential, commercial and industrial applications. Has been developed to carry out the following safety measurements of electrical installations in accordance with EN 61557 and DIN VDE 0100: Insulation resistance, RCD tests, Low Ohm resistance, Earth ground resistance, Loop impedance, Phase sequence.
-
product
Voltmeter According to DIN EN 61010-1 (VDE 0411-1)
PeakTech Prüf- und Messtechnik GmbH
An innovative graphic multimeter with a 50,000-digit color TFT display for precise measurements with a high DC basic accuracy of 0.05%. The internal data logger enables the recording of measured values, which can be recorded over a period of several hours and the transfer to a Windows PC at a later time is ensured. Internally stored measured value recordings can also be accessed and graphically displayed on the multimeter itself or on the PC. Via Bluetooth, the measured values can also be displayed live via app for Android and iOS devices, recorded in a table and e.g. send by email for further processing. This multimeter has a variety of measurement functions for direct and alternating voltage measurements (incl.ACV + DCV), direct and alternating current measurements, resistance, capacitance, frequency or temperature, whereby alternating voltage and alternating current are recorded as True RMS values. Due to the extensive measurement functions and the intuitive operation, this device is ideally suited for every electronics engineer, technician and engineer who attach great importance to a precise, indestructible and technically powerful multimeter.
-
product
Biconical Antennas
For many years most standards called for the use of a half-wave dipole antenna set for frequencies above 80 MHz. However, to reduce test time, broadband antennas such as the biconical antenna and log periodic antennas began to be accepted. Broadband antennas, compared to half wave dipoles, reduce test time because the technician did not have to stop the test to adjust the dipole antenna for each frequency. A.H. Systems'' 7 models of Biconical Antennas operate efficiently over the frequency range of 20 MHz to 18 GHz. Suitable for FCC, MIL-STD, VDE, TEMPEST, and immunity testing, each Biconical antenna will provide reliable, repeatable measurements.
-
product
12.5 mm Test Sphere Probe
CX-12.5
Shenzhen Chuangxin Instruments Co., Ltd.
The rigid sphere (12.5 mm) from Autostrong is designed and manufactured to perform the test specified in many standards (IEC 60335, IEC 60065, IEC 60745, IEC 61029, IEC 60950) to prove the degree of protection for the first characteristic numerals 2 (IP2X) .Its is designed to meet the requirements of international safety regulatory agencies such as UL, DNV, IMQ, BVSQ, ITS, IRAM , CSA, VDE, DIN , INMETRO.
-
product
PCI Bus Analog Output Board, 8 Isolated Outputs, 14 Bit
APCI-3501-8
*8 analog output channels*Optical isolation 500 V*Settling time 30 µs typ.*14-bit resolution (13 bit for 0-10 V)*Output voltage: ±10 V, 0-10 V (switchable through software)*Output voltage after reset: 0 V*Each output channel has its own ground line (without optical isolation from the others)*Driver capacity: 5 mA/500 pF*Short-circuit protection, EMI filters*Noise neutralization of the PC supply*Creeping distance: 3.2 mm acc. to DIN VDE 0411-100*Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary*2 digital input channels, 24 V, isolated*2 digital output channels, 24 V, isolated
-
product
Standard Gain Horn Antenna
SAS-586
This Standard Gain Horn Antenna will provide reliable, repeatable measurements. An ideal solution and a standard workhorse of any EMC test house for compliance testing. Features: 12.4 GHz to 18 GHz, Individually Calibrated, FCC, MIL-STD, VDE and TEMPEST Testing.
-
product
Phase Detector
Paula
BAUR Prüf- und Messtechnik GmbH
BAUR paula phase detector. The paula phase detector is used for clear phase identification in earthed and shorted medium and high-voltage cables. With the help of the measurement procedure tried and tested over many years, paula delivers precise phase allocation without scope for interpretation and corresponds to the highest safety standards for tasks on and close to electric equipment.* Clear phase determination possible in cable lengths up to 40 km* Highest level of safety when used on earthed and shorted cables in compliance with EN 50110-1 (DIN VDE 0105-100)* Suitable for all switchgear constructions due to compact design of the signal injectors* Ready for operation for up to 2 weeks (standby mode)
-
product
PD Measuring System
TEM
Partial discharge test system for laboratory or on-site measurement according to VDE 0434, IEC 60270 and EN50178 consisting of:*Partial discharge meter TMG*High-voltage coupling capacitors for decoupling of the PD pulses*Partial discharge calibrator TPK for determining the correction factor in the PD test circuit
-
product
Wire And Cable
Chengdu Mengsheng Electronics Co., Ltd.
We provide a variety of wire and cable products, including insulated wires, power cords, stranded wires, solid wires, wiring harnesses and connectors. Our products are widely used in security, medical, communications, instrumentation, medical, home appliances, auto parts, military, aerospace and other industries. Our products strictly comply with the product certification standards of countries and regions such as UL in the United States, VDE in Germany, CE in the European Union, and BS in the United Kingdom.
-
product
Ammeter According to DIN EN 61010-1 (VDE 0411-1)
PeakTech Prüf- und Messtechnik GmbH
Is a measuring device for AC and DC currents up to 1000 A using a current clamp for conductor diameters up to 48 mm. Current and voltage measurements are carried out as true RMS (true rms value) measurements, which means that the measured values are displayed correctly even with waveforms that deviate from a sine wave.
-
product
Impulse Tester
MIG2412SPD
The MIG2412SPD is a impulse tester for testing SPD (Surge Protection Devices) in accordance with IEC 61643-1 and VDE 0675. Up to maximum 24kV/12kA making it suitable for testing Class I to III or in accordance with VDE Class A,C, D. The MIG2412SPD is a hybrid generator with a voltage wave shape 1,2/50 ìs at "no load" and a current wave form 8/20 ìs at short circuit for testing Class III (D) SPD connected to power line.