Filter Results By:
Products
Applications
Manufacturers
-
product
Digital Insulation Multimeter Tester 1 KV
MIRT-61
The Motwane Manufacturing Company
The MOTWANE multipurpose tester Model MIRT-61 is a Versatile, battery operated Digital insulation tester with true RMS industrial grade multimeter features best suited for industrial preventive maintenance. With test voltage range up to 1 KV , highest insulation resistance range of 6G Ohm and multi featured function of RMS multimeter (i.e. AC/DC 1000 V) ; makes it a superior offering for Industry and Service segment. It is designed predominantly for low voltage insulation resistance testing in maintenance and services, which involves the applications like Cables/Wires, Rotating Machines, LT transformers, Switchgears and Industrial installations. It is designed to suit the extreme environment conditions. Save your operating cost and test more with this single box design rather buying two different products.
-
product
Transformer DC Winding Resistance Tester
HTZZ-100A / 248
Wuhan Huatian Electric Power Automation Co., Ltd.
Applicable for transformer to submit the dc resistance testproject around group in pick up and overhaul project.
-
product
DC Resistance Tester
GDZRS-20A
GDZRS series Winding DC resistance tester is optimal designed for measuring three phase winding DC resistance of big capacity transformer. It can test three phase winding DC resistances at the same time
-
product
High Quality Transformer Oil Dielectric Strength Tester
AS-023A
Chongqing Assen Power Equipment Co., Ltd
AS-023A Series High Quality Intelligent Transformer Oil Dielectric Strength Tester is specially designed for testing dielectric strength (Breakdown Voltage) of transformer oil. The breakdown voltage (dielectric strength) is one of the most important parameters of transformer oil, it is a rule of the voltage withstand. The value of breakdown voltage (dielectric strength) indicates whether the oil contains water, impurity and electric particles, and you’ll know the oil value via the breakdown voltage (dielectric strength).
-
product
1μΩ-4kΩ AC Milliohmmeter Low Resistance Tester
TH2521
Shenzhen Chuangxin Instruments Co., Ltd.
TH2521 AC Milliohmmeter is a high-performance and intelligent tester widely used to test contact resistance, internal resistance and battery voltage. The application of constant current source with 1kHz frequency can greatly eliminate the potential error caused by thermoelectricity on DUT. This meter has the function to automatically detect contact failures on test cable. At the range of 30mΩ, basic R resolution can reach 1μΩ. It is applicable for transformer, inductance coil copper resistance, relay contact resistance, switch, connector contact resistance, wire resistance, PCB line and via reistance dan metal defect detection, etc. In the mean time, signals, such as HIGH, LOW, PASS, can be output through HANDLER interface, thus it is very convenient to be used in automatic production line.
-
product
Digital Low Resistance Tester
TH2512
Shenzhen Chuangxin Instruments Co., Ltd.
The TH2512 series digital dc low resistance tester i s an intelligent, wide range, high-precision tester which suitable for transformer, inductor copper resistance, relay contact resistance, switches, connectors, wire resistance, contact resistance component solder contact resistance, PCB line, welding hole resistance and metal detection, etc. It’s applied to the production line and can use HANDLER interface and GPIB interface (option) output good/bad signal, in order to improve production line automation testing capability.
-
product
Millohm & LCR
Help prevent failures in motor windings, generators and transformers with a quick and easy resistance test using an Amprobe milliohm meter. To efficiently inspect and verify electronic components for quality control, choose an Amprobe LCR tester.
-
product
Multi-Function Transformer Turns Ratio Tester (TTR)
HTBC-V / 252
Wuhan Huatian Electric Power Automation Co., Ltd.
Suitable for transformer testing of three-phase transformer, z-winding transformer, rectifying transformer and railway electrical system.
-
product
Transformer Performance Tester
6691
applying ±90V voltage on the winding of the transformer demagnetized and get the voltage value on the terminal and the current value in the winding to draw the hysteresis characteristic curve. This method can be used for linear quantitative analysis of residual magnetism in transformers, and fast demagnetization can be achieved by tracking hysteresis curves. The analyzer can measure magnetism residual rate before and after demagnetization.
-
product
Flash Point Tester
Weshine Electric Manufacturing Co., Ltd
Closed flash point tester, when the test sample is used in a closed environment (such as transformer oil), to determine the closed flash point value of petroleum products. Use touch screen instead of keyboard operation, adopt foreign advanced technology, large LCD screen LCD full Chinese display man-machine dialogue interface, full screen touch key prompt input, convenient and fast, open, fuzzy control integrated software, modular structure, in line with national standards, the United States, EU and other standards.
-
product
Transformer DC Winding Resistance Tester
HTZZ-5A / 230
Wuhan Huatian Electric Power Automation Co., Ltd.
Applicable for transformer to submit the dc resistance testproject around group in pick up and overhaul project.
-
product
Current Transformer Testers
Vanguard Instruments Company, Inc.
Performs CT excitation, current-ratio, polarity, and phase angle testsMeasures insulation resistance and winding resistance of the CT seconday windingsMeasures the CT's secondary burdenTest record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-commentsBuilt-in 4.5-inch wide thermal printerPlot Multiple Saturation CurvesStores up to 128 CT test plans and 140 test records internallyUSB, Bluetooth, and USB Flash drive interface
-
product
Distribution Transformer Tester
NDB-DOC™
The NDB-DOC™ is a test instrument designed for distribution networks transformers from 10kVA to 2500kVA. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding & also short circuits on the secondary winding. The NDB-DOC™ is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings.
-
product
Transformer/Capacitor Test Sets
*Quick and easy check for opens or shorts on transformers or capacitors before energizing*Provides clear indications of open circuits, short connections and confirmation that the test results are OK*Tests overhead, pad-mount and other distribution transformers as well as capacitors and capacitor banks*Tests the primary and secondary sides of de-energized transformers and capacitors without disconnecting*Helps prevent line workers from installing a fuse on a shorted transformer or capacitor*Automatic self-test featureMagnet holds the tester in place while testing
-
product
AC High Voltage Break Down Tester
High Voltage Breakdown Testers also known as Hipot Testers or Insulation Testers are a necessity for any Transformer testing, Substation equipment testing, Cable testing, Panel testing and testing of various insulating materials. Insulation testing is very important to ensure and maintain the safety of electrical equipments and also for the safety of operator.
-
product
Three-circuit Transformer DC Resistance Tester
HTZZ-S10A / 218
Wuhan Huatian Electric Power Automation Co., Ltd.
Designed to meet the dc resistance test of three-phase winding in large capacity transformer.
-
product
Transformer Oil Dielectric Breakdown Voltage Tester
MG-II
Chongqing Kailian Yongrun Industrial Co.,Ltd.
The dielectric breakdown voltage test (BDV test) is an important test to determine the breakdown voltage of insulating oils. After a certain period, transformer oil will be degraded, and there are moisture, gas and impurity in oil. Then, the quality of transformer oil is affected. So it is necessary to test the transformer oil. BDV test is one of the most common tests to insulating oils.
-
product
Transformer Tester
Kvtester Electronics Technology Co.,Ltd
High precision instrument for measuring characteristic parameters of transformer capacity, no-load and load. The instrument is a multi-function measuring instrument, which is equivalent to the usual two kinds of test instruments: the transformer capacity tester + transformer characteristic parameter tester. The utility model can precisely measure a series of power frequency parameters of a plurality of transformers, such as the capacity, the type, the no-load current, the no-load loss, the short circuit (load) loss and the impedance voltage.
-
product
Transformer Turn Ratio Tester
KVBB-II
KV Hipot Power Test Equipment Co.,Ltd
KVBB-II Transformer turn ratio tester is used to check turn ratio of transformer, tap switch situation, whether transformer interturn is short circuit and transformer can run in parallel or not.
-
product
CT Burden Tester
585
The 585 Burden Tester is a hand held unit rated for use up to 20A. The design features a digital LED meter for displaying the current transformer (CT) secondary current. The burden is applied for a specific length of time controlled by circuitry inside the unit to help prevent the burnout of the burden elements.
-
product
Turns Ratio Testers
TRT Advanced Series
TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.
-
product
DIGITAL TURNS TESTER AND DIGITAL LCRTZ METER
TURNS-LCRTZ
Digital TURNS TESTER with LCR for Counting / Measuring Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity , DC Resistance , Inductance (L), Capacitance (C), DC Resistance, Rac, Q, D, ESR and Tan.Toroidal Turns Platforms :TTPT100 : 5 T - 1000 T , TTPT1000 : 500T-10000 T The Platform has 2 connections for the coil and 2 for the probe wire. Measurement principle is based on dynamic comparison of the voltage across one turn and the coil. You will be able to get the polarity or winding indication with respect to the one turn reference.Accuracy : + 0.2% + 0.5T for high and medium permeability cores at suitable test frequency. Internal Diameter must be able to pass a wire as thin as 0.2 mm. External Diameter as high as 200 mm.Test Frequency Selectable in Step : 50 Hz, 100 Hz , 500 Hz, 1 KHz, 5 KHz, 10 KHz. Test Voltage adjustable : 100mV to 1V in steps of 50mV.
-
product
5kV Insulation Resistance Tester
KV3122
KV Hipot Power Test Equipment Co.,Ltd
KV3122 Insulation Resistance Tester is suitable for measuring the resistance of various insulating materials and the insulation resistance of transformers, motors, cables and electrical equipment. Digital insulation resistance meter is composed of medium and large scale integrated circuits, including high-precision micro current measurement system, digital boost system and automatic discharge circuit.
-
product
Transformer Winding Resistance Testers / TRT ? 27
TRT-27 series
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Fast measurement: Test current 2.5A to 20A, Digital display of resistance and test current.
-
product
Transformer Turns Ratio Tester
CX-BY
Shenzhen Chuangxin Instruments Co., Ltd.
It is to test voltage ratio, vector, polarity, ratio error of current transformer and voltage transformer.
-
product
Fully Automatic Transformer Winding Resistance Tester
Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.
-
product
DC Hipot Test Set
KVZG
KV Hipot Power Test Equipment Co.,Ltd
DC Hipot Tester is applied to measure output voltage and leakage current for zinc oxide arresters, magnetic blowing arresters, power cables, generators, transformers, circuit breakers and other equipment.
-
product
Surge Tester (Impulse Winding Tester)
SS6815 / SS6815F
Surge testers (impulse winding tester) is used for testing and check the insulation grade of turns between turns, insulation grade of layers between layers, insulation grade of windings between turns. It is used widely for transformer, current sensor, voltage sensor, relay, contactor, inductor, motor, generator, valve coil, voice coil, etc.
-
product
Primary Current Injection Testers
Primary current injection tests are carried out during commissioning and certification of various types of switchgear and current transformers (CT), as well as during diagnostics of grounding circuits, testing circuit breakers and other devices. Primary current injection testers can also be used for determining the terminals polarity and transformation ratio of current transformers, thermal testing of electrical devices, testing automatic reclosers and sectional disconnectors.
-
product
Digital LOOP/PSC/LOAD Tester
2811 LP
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Displays and sound warning if external voltage present.● Displays mains voltage, scroll trough menus.● Checks wiring integrity (LEDs and display).● Single button operation.● Auto-off/auto-ranging.● Combined prospective short circuit current, PSC and LOOP tester.● Built-in carry case, test leads in separate pouch.● Loop test for L-E and L-N and PSC.● Voltage test L-N and L-E.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for special orders.● 60Hz available on request.