Filter Results By:
Products
Applications
Manufacturers
-
product
Automatic Oil Tan Delta & Resistivity Kit
MOTR
The Motwane Manufacturing Company
Motwane's MOTR is multifunctional automatic test kit designed for accurate measurement of the Dielectric Constant, TanDelta, Resistivity & capacitance of transformer oil & other electrical insulating liquids. It has preprogrammed test sequences as per various International standards along with customized test sequences as per user requirements. Internal memory for 250 tests provided with PC interface & report generation facility. Inbuilt thermal printer for onsite results. Test cell is designed as per IEC247 with calibrator for onsite calibration of kit.
-
product
Standard Voltage Transformer
HJ / 635
Wuhan Huatian Electric Power Automation Co., Ltd.
It is mainly designed for the voltage transformer calibration standard of basic power supply and production department.
-
product
LVDT Sensor Amplifiers
Analog Devices signal conditioning ICs, together with linear variable differential transformers (LVDTs), can be used to convert mechanical position to a dc voltage. The IC provides both the excitation for the LVDT and the output conversion to dc level with a user selectable gain. ADI LVDT signal conditioners are available to interface with a wide range of LVDTs, including half bridge and standard 4- and 5-wire.
-
product
Autotransformer
T-1007
The Titan Series T-1007 Auto-transformer is used to conveniently scale the standard OV to 130V / 260V full scale Titan AC Power Source/Frequency Converter output to either X .5 stepdown (OV to 65V) or X2 stepup (OV to 520V). It has a 1.2 KVA power rating with excellent bandwidth and voltage regulation.The unit is of toroidal design, making it approximately half the size and weight of a comparable stacked laminate transformer. It is center filled with epoxy for isolation and durability, and features simple 1/4" bolt center mounting.
-
product
NI-9242, 250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module
783107-01
250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9242 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, standard potential transformers, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9242 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta.
-
product
ANSI Metering Current Transformer Burden
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
product
Transformer Test Panel/ Setup
This is a common test panel for distribution/ power transformers of different specifications. The user can perform most of the factory tests, as per the relevant IS standard for the transformers. The panel consists of power analyser, meters for high voltage test, meters for induced voltage test etc, control for all the tests, protection and interlock circuits so that a single panel can be used to conduct a number of tests using only one dimmerstat and the associated devices
-
product
AC DC Current and Voltage Converters
The DAT5023 I is an AC or DC current converter, the input current range is selectable on order from 0-5Amps, 0-10Amps, 0-20Amps, 0-25Amps, 0-30Amps, 0-40Amps, 0-50Amps, 0-60Amps. It measure the current with the use of a Hall effect transducer. There is a coil (current transformer) inside the current converter which is isolated from the current input. The cable passes through the housing of the converter and the coil and the true root mean square measurement is taken from this coil then converted to a standard industrial signal output.
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
product
Meter Testing System
ASTel
Three-phase Meter Test Equipment of ASTeL 3.2x.x series system is a fully automatic system enabling simultaneous, multi-position calibration and legalization of electric energy meters. The automatics include power sources, reference standards, stand controllers, photoelectric scanning heads, separating transformers, and other elements of the system. All these elements are controlled through a Windows based executive program.
-
product
BDV Transformer Oil Test Sets
NMC''s Transformer BDV Oil Test Set is a portable unit as per relevant Indian Standard Specification IS :6792 :1992, suitable for operation on 230 / 240 Volts, A.C. 50 Hz. A three core flexible cable is connected to the unit with three pin socket to connect the mains. The H.V. Transformer is a completely dry, resin encapsulated with two H.V. terminals with mounting saddles. The center point of the transformer is earthed, so that the voltage of each terminal to earth is only half the test voltage.
-
product
Embedded Synchro - Resolver -
LVDT I/O Cards
Computer Conversions Corporation
100% Transformer Isolation is offered for all AC I/O, and various Isolated DC converters are available as standard product, eliminating concerns for ground-loops, ground interjected (intermittent and ghostly) field noise, inductive surges, differing potentials, and high voltage field transients from effecting the card itself, the sensitive ISA bus backplane and any other device or system sharing these signals.
-
product
SF6 Filled High Precision Standard Capacitors
YL Series
Shanghai Jiuzhi Electric Co., Ltd.
The SF6 insulated standard capacitor is used as Capacitance standard in measuring bridge Circuits to measure the dielectric dissipation Factor tanδ of all types including cables, capacitors, bushings, instrument transformers and power transformers. Further-more, It can be used as high-voltage capacitor for voltage divider circuits of high-voltage transformer test.
-
product
Precision Multirange Voltage Transformers
WP-36000
The WP-36000 Transformer is primarily a laboratory standard. The high degree of accuracy and multiplicity of ranges makes this transformer the standard for precision calibration work. With the aid of this transformer, very accurate determination can be made of the ratio and phase angle characteristics of voltage transformers having ratings from 14,400 to 36,000 volts.
-
product
Multiple Gas Transformer DGA
MULTITRANS
The MULTITRANS is an 8-gas on-line transformer DGA monitoring unit designed to monitor a bank of three single-phase transformers in close proximity. Based on the same core technology as the highly successful TRANSFIX the MULTITRANS measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm).
-
product
Analog Power Supply
Type NPS-2412
National RF's Type NPS-2412 analog power supply was designed to be used in communication equipment where radiated switching inverter noise from conventional “switching type” supplies is not acceptable. The power supply consists of a standard rectified transformer output driving a pair of voltage regulators and filtering networks. The 2412 offers an adjustable voltage output between 2 and 24 volts as well as a fixed voltage output of 12 volts. A maximum of 20 Watts of DC power can be supplied from the unit. As the voltage regulators dissipate power in the regulation process, the power to the load is derated accordingly, dependent on the set voltage to the load. The adjustable regulator is a standard LM-317T integrated circuit device. The fixed regulator is a standard LM 7812 device. Upon customer request, the LM 7812 device may be changed to any voltage rating within the the LM-78xx series of regulators. Contact National RF for this modification if desired.
-
product
ANSI Potential Transformer Burdens
The ANSI Potential Transformer Burden Model PB-96-ANSI is designed for loading the Voltage transformers during accuracy tests as per ANSI standard C57.13. The PB-96-ANSI is a dual input ANSI burden providing the inputs of both 120V & 69.3V. It can be used along with the ELTEL Automatic Instrument transformer Test Set. AITTS-98 to test VTs as per ANSI standards.
-
product
Computer Control 6-Phase Relay Protection Tester
GDJB-PC6
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
1.This tester with standard 6 phase voltage, 6 phase current output,2.Voltage 125V/phase, current 30A/phase, 6 phases in parallel can up to 180A.3.Digital Signal Processor Microcomputer.4.Not only test the traditional relays and protectors, but also test the modern micro computer replays, special for transformer differential protection and transfer equipments.
-
product
Differential Transformer Type Extensometers
DT Series
ISO Class 1 Compliant Differential Transformer Type Extensometers The ISO 6892-1 standard for tensile testing of metallic materials prescribes Class 1 or higher extensometers, and JIS Z2241 prescribes Class 2 or higher extensometers when measuring withstanding pressure. The DT series includes Class 1 compliant differential transformer type extensometers, which can be used to implement test methods compliant with metal tensile test standards.
-
product
Instrument Transformer
Our company has achieved a reputed niche in international market by manufacturing and exporting a great range of Instrument Transformer. Widely used in electrical, power generation and engineering sector for transforming voltage or current level, this equipment is in accordance with industry standards. Manufactured using excellent grade raw materials sourced from reputed vendor, Instrument Transformer is offered to clients in different technical specifications. We stringently test this instrument on varied standard parameters.
-
product
IEC61588 And IEC60065 Mandrel Test Apparatus
CX-M01
Shenzhen Chuangxin Instruments Co., Ltd.
IEC61588 and IEC60065 Mandrel Test Apparatus is designed and manufactured in accordance with the standard requirements of IEC61558 and IEC60065. The IEC61588 and IEC60065 Mandrel Test Apparatus is used for the insulating thin layer of the power transformer and supply unit as well as the similar products to do the spindle test, mechanical strength test and abrasion test.
-
product
Partial Discharge Measuring System
LDS-6
The Doble LDS-6 is a highly sophisticated digital measuring system for partial discharge detection and analysis. It is trusted as a valuable tool for factory and laboratory testing.The LDS-6 can be used to test a variety of high voltage apparatus. Use the LDS-6 to perform PD quality tests on motors, generators, transformers, MV and HV cable systems, switchgear and additional HV accessories.The LDS-6 complies with IEC 60270, VDE 0434 as well as various IEEE and other standards.
-
product
Automatic Meter Reading Unit
Signals & Systems India Private Limited
SANDS make of AMR Modem SAM-1101 is a smart electricity meter reading device that can be connected to any make of electronic energy meter by means of optical/ RS232 port, which is compliant to DLMS – IEC 62056-21 standard. The electricity meters measuring energy consumption can be located in either consumer premises or in distribution transformers. The modem draws its power from the meter terminal block and connects to the communication port of the meter. Thus this add-on energy meter reading system is non-intrusive and can be retrofitted easily to any meter. The Electricity Meter Reading device uses GSM/GPRS communication technology and has built-in intelligence to talk to the DLMS meter. AMR system is compatible with 4G network to push the power consumption-billing data, load survey data, and event data to a cloud-based server, with fallback options to 3G & 2G.
-
product
ST Fully-auto BDV Dielectric Oil Tester Set
Chongqing Assen Power Equipment Co., Ltd
ST BDV Dielectric Oil Tester is ideal for speedy and accurate testing of dielectric strength of transformer and circuit breaker oil under-test room condition in accordance with international standard.
-
product
Current Transformers Test Set
Supreme Instrument Laboratories
The basic unit is sensitive magnetic comparator and also it incorporates electronic null detector to facilitate the balance. The reference Current 5A. or IA. obtained from Standard Current Transformer and in comparison to that the vector length and phase displacement is measured. The ratio error in percentage and phase displacement in minutes are directly compared and indicated on dials.
-
product
Isolated LVDS
Isolated LVDS (low voltage differential signaling) devices couple differential signals applied to the LVDS receiver inputs across the isolation barrier to the outputs on the other side and re-transmits the bit stream or clock as LVDS. Analog Devices' drop-in LVDS isolators offer designers robust, high speed differential signaling for point-to-point and multidrop applications. Extending iCoupler® chip scale transformer technology for ultrahigh speed data encoding, these LVDS isolators support a a data rate of up to 2.5 Gigabits per channel for a total bandwidth of 10 Gbps. In contrast to expensive fiber implementations, deserialized links over standard digital isolators or optocouplers, and design-intensive bespoke solutions using transformers or high voltage capacitors, ADI Gigabit Digital LVDS isolators offer the only integrated comprehensive, high performance isolation at 10 Gbps. High performance galvanic isolation for applications include analog front-end (AFE), processor to processor serial communication, or video and imaging data (such as HDMI isolators) as well as isolation between boards, or at a cable interface for LVDS or CML signal chains.
-
product
ANSI Standard Burden Sets
Voltage and Current
Testing and calibrating instrument transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. The burden sets described below have been carefully designed to meet these requirements.
-
product
Transformer Winding Resistance Meters
TWA Standard Series
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
product
Aging and Life Test Rack
SY2036
SY2036 Aging and life test rack is fully designed according to the IEC standard, and can also be designed based on the customer request. SY2036 can test LED, CFL, HID Indoor lamp and Outdoor lamp. Input Power supply: AC220V, 50/60HZ, 12KVA Min (110V is option) • Built-in transformer: 0-250V 5KVA and 0-300V 5KVA (Other power is option) • Maximum power for EUT: 5KVA and 12A (Other power is option) • EUT and Number: 112pcs B22, 112pcs E27. 36pcs T5/T8/T12 Tube. 32pcs LED panel (Other EUT can be designed according to customer request) • ON/OFF test: Can be set on the touch screen with program • Test number: 0~99999(Adjustable)
-
product
Telecom Transformers
Our high-performance telecom transformers support multiple home phone line and power line network applications. These transformers have excellent THD performance, small footprints, and are designed to exceed industry standards. Single, dual, quad, six, octal and twelve transformer numbers are available.