Filter Results By:
Products
Applications
Manufacturers
-
product
ANSI Metering Current Transformer Burden
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
product
Turns Ratio Testers
TRT Standard Series
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
product
903 Benchtop Three Phase 40A
Weshine Electric Manufacturing Co., Ltd
1. The instrument has standard four phase voltage and three-phase current output. It can test not only various traditional relays and protection devices, but also various modern microcomputer protections, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. Classic Windows XP operation interface, friendly man-machine interface, easy and fast operation; high performance embedded industrial control computer and 8.4 inch resolution 800 × 600 TFT true color display screen, can provide rich and intuitive information, including the current working state of the equipment and various help information.
-
product
Precision Multirange Current Transformer
P-5000
The P-5000 transformer is a laboratory standard. The unit’s excellent accuracy and the Knopp One-to-One calibrating feature make this precision transformer well-suited as a standard for calibration work. This transformer can provide a very accurate determination of the ratio and phase angle characteristics of current instrument transformers having ratios from 5 to 5,000 amperes. This transformer also can accurately extend the range of a 5 ampere ammeter or wattmeter to cover all current values up to 5,000 amperes.
-
product
VOLTAGE TRANSFORMERS
Designing & manufacturing a range of high quality, voltage transformers in three different frame sizes for both measuring and protection duties. Transformers which are designed to comply with the requirements of IEC 61869-3 or other international standards as required can be supplied to satisfy most Low Voltage applications.
-
product
Transformer Test Panel/ Setup
This is a common test panel for distribution/ power transformers of different specifications. The user can perform most of the factory tests, as per the relevant IS standard for the transformers. The panel consists of power analyser, meters for high voltage test, meters for induced voltage test etc, control for all the tests, protection and interlock circuits so that a single panel can be used to conduct a number of tests using only one dimmerstat and the associated devices
-
product
Computer Control 6-Phase Relay Protection Tester
GDJB-PC6
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
1.This tester with standard 6 phase voltage, 6 phase current output,2.Voltage 125V/phase, current 30A/phase, 6 phases in parallel can up to 180A.3.Digital Signal Processor Microcomputer.4.Not only test the traditional relays and protectors, but also test the modern micro computer replays, special for transformer differential protection and transfer equipments.
-
product
AC Calibration Standard
1U647-001
The 1U647-001 is a low cost calibration standard used to determine if a 1U632-100 or a 1U663-100 DMU requires factory calibration. Its portability makes it ideal for field-testing. The standard generates signals that simulate the aircraft’s resolvers, rotary variable transformers (RVTs), and linear variable displacement transformers (LVDTs). The unit also generates a pulse width modulated (PWM) signal, and routes the output of an ARINC 429 source to the different DMU input channels. The calibration standard connects directly to the DMU and replaces the output signals of an active extender card. Discrete switch settings simplify testing. The unit is housed in a rugged aluminum case.
-
product
Embedded Synchro - Resolver -
LVDT I/O Cards
Computer Conversions Corporation
100% Transformer Isolation is offered for all AC I/O, and various Isolated DC converters are available as standard product, eliminating concerns for ground-loops, ground interjected (intermittent and ghostly) field noise, inductive surges, differing potentials, and high voltage field transients from effecting the card itself, the sensitive ISA bus backplane and any other device or system sharing these signals.
-
product
IEC Standard Burden Sets (Current)
IEC Burden Sets
Testing and calibrating current transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. These burden sets have been carefully designed to meet these requirements. They also provide the standard burdens required for the testing of current transformers for metering service, and for the testing (within the current rating provided by the sets) of current transformers for relaying applications, all as called for by IEC (International Electrotechnical Commission) Publication 185: 1987.
-
product
Current Transformers & Bushings
Measurements International Ltd.
AC Current Transformer, Reference Standard for the Calibration of Precision CTs, Currents as high as 10,000 A, Portable with carrying handle for smaller CTs, Wheels on heavier CTs, Passive or Electronically Aided Compensation.
-
product
Insulating Oil Dielectric Loss Tester
HDLT
Hention Electrical Equipment Co., Ltd.
This integrated precious insulation oil dielectric loss tester is for measuring dielectric loss TAN and capacitance of transformer insulation oil.This is a high precision instrument; integrated with oil cup, temperature control instrument, temperature sensor, dielectric loss test bridge, AC test power, and standard capacitor, etc.
-
product
Standard Current Transformer
HL / 640
Wuhan Huatian Electric Power Automation Co., Ltd.
It is used as the calibration standard of current transformer in the error test of transformer.
-
product
CT Analyzer
The CT Analyzer is the most complete testing system for protection and metering CTs according to IEEE and IEC standards. It allows all types of single and multi-ratio current transformers to be tested on-site in power system grids.
-
product
ST Fully-auto BDV Dielectric Oil Tester Set
Chongqing Assen Power Equipment Co., Ltd
ST BDV Dielectric Oil Tester is ideal for speedy and accurate testing of dielectric strength of transformer and circuit breaker oil under-test room condition in accordance with international standard.
-
product
Differential Transformer Type Extensometers
DT Series
ISO Class 1 Compliant Differential Transformer Type Extensometers The ISO 6892-1 standard for tensile testing of metallic materials prescribes Class 1 or higher extensometers, and JIS Z2241 prescribes Class 2 or higher extensometers when measuring withstanding pressure. The DT series includes Class 1 compliant differential transformer type extensometers, which can be used to implement test methods compliant with metal tensile test standards.
-
product
ANSI Standard Burden Sets
Voltage and Current
Testing and calibrating instrument transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. The burden sets described below have been carefully designed to meet these requirements.
-
product
904 Benchtop Six Phase 30A
Weshine Electric Manufacturing Co., Ltd
1. The instrument has standard six phase voltage and six phase current output. It can test not only traditional relays andprotection devices, but also modern micro-computer protection devices, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. can be connected to laptop (optional) to run.Laptops and industrial computers use the same set of software, so there is no need to relearn the operation method.
-
product
Test Switches
Series FT
An industry standard for CT & VT isolationfor instrument transformer and connected device testing.Up to 10 poles; Numerous configurations availableTypically mounted on switchgear and relay panels10 pole test plug available; UL and cUL recognized.
-
product
Ratio Standards
Ratio Standards by Tegam including ratio transformers, synchro-resolver bridge, synchro-resolver standard
-
product
Partial Discharge Test Set
We are an unparalleled name in the industry, engaged in manufacturing and exporting Partial Discharge Test Set that is broadly used for instrument transformers to test the discharge of voltage. This test set is manufactured in compliance with set international quality standards using optimum quality components under the observations of our experienced professionals. Further, it is made available in several specifications to meet the exact requirements of the clients. Our offered Partial Discharge Test Set can be owned from us at nominal prices.
-
product
Gigabit Ethernet PCI Express Mini Card
mPCIe-LAN-GbE
The mPCIe-LAN-GbE is a type F1 PCI Express Mini Card (mPCIe) optimized for use in mobile and rugged environments, with latching connectors and protection on all signals. The onboard magnetics feature robust built in isolation via transformer coupling. In addition, extended operating temperature and RoHS compliance are standard.
-
product
IEC61588 And IEC60065 Mandrel Test Apparatus
CX-M01
Shenzhen Chuangxin Instruments Co., Ltd.
IEC61588 and IEC60065 Mandrel Test Apparatus is designed and manufactured in accordance with the standard requirements of IEC61558 and IEC60065. The IEC61588 and IEC60065 Mandrel Test Apparatus is used for the insulating thin layer of the power transformer and supply unit as well as the similar products to do the spindle test, mechanical strength test and abrasion test.
-
product
Transformer Turns Ratio Meter
We are considered as one of the leading manufacturers and exporters of Transformer Turns Ratio Meter With/ Without Phase. The equipment is widely used in power generation and engineering industry for testing of transformers. We engineer and develop this testing equipment in accordance with industry standards using best grade components and raw materials. This Transformer Turns Ratio Meter With/ Without Phase can be also optimized according to client's specific requirement. We offer this testing equipment at competitive price.
-
product
Transformers
Chengdu Mengsheng Electronics Co., Ltd.
As a leading transformer manufacturer, DOREXS is committed to providing a variety of high-performance standard and customized transformers to meet the power needs of various industries.DOREXS has a professional R&D design team and advanced production technology to ensure that our transformers are at the forefront of the industry. At the same time, they are strictly produced in accordance with international standards to ensure that the performance and stability of each transformer are maximized.Our products cover dry type transformers, single phase transformers, three phase transformers, high frequency transformers, toroidal transformers, R core transformers, EI core transformers, isolation transformers and special transformers.If you need to know more about our products and services, please feel free to contact us.
-
product
CT & PT Test Kit
PCT200i
PCT200i is specially designed for current transformer characteristic test.This CT analyzer can finish the measurement class CT and TYP class CT.The additional functions include ratio and angle differential tests (the measurement points in the GB standard),FS and inductance,steady-state parameters,peak error and transient parameters,etc.
-
product
Automatic Meter Reading Unit
Signals & Systems India Private Limited
SANDS make of AMR Modem SAM-1101 is a smart electricity meter reading device that can be connected to any make of electronic energy meter by means of optical/ RS232 port, which is compliant to DLMS – IEC 62056-21 standard. The electricity meters measuring energy consumption can be located in either consumer premises or in distribution transformers. The modem draws its power from the meter terminal block and connects to the communication port of the meter. Thus this add-on energy meter reading system is non-intrusive and can be retrofitted easily to any meter. The Electricity Meter Reading device uses GSM/GPRS communication technology and has built-in intelligence to talk to the DLMS meter. AMR system is compatible with 4G network to push the power consumption-billing data, load survey data, and event data to a cloud-based server, with fallback options to 3G & 2G.
-
product
Induced Over Voltage Test Set
We are highly experienced in manufacturing and exporting Induced Over Voltage/DFDV Test Set. It is widely used in electrical and power sector to test different types of transformers. Our range includes different models of testing set to meet clients' diverse requirements. Manufactured in accordance with industry standards, this Induced Over Voltage/DFDV Test Set is offered to clients at competitive price.
-
product
ANSI Relaying Current Transformer Burden
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
product
BDV Transformer Oil Test Sets
NMC''s Transformer BDV Oil Test Set is a portable unit as per relevant Indian Standard Specification IS :6792 :1992, suitable for operation on 230 / 240 Volts, A.C. 50 Hz. A three core flexible cable is connected to the unit with three pin socket to connect the mains. The H.V. Transformer is a completely dry, resin encapsulated with two H.V. terminals with mounting saddles. The center point of the transformer is earthed, so that the voltage of each terminal to earth is only half the test voltage.