Filter Results By:
Products
Applications
Manufacturers
-
product
AC Voltage Proving Units
HLV-1
Standard Electric Works Co., Ltd
● Designed to proof. AC voltage detectors AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.
-
product
AC Voltage Proving Units
HLV-2
Standard Electric Works Co., Ltd
The AC Voltage Detectors and AC Voltage Testers utilized to determine if the devices under test are functionally working. They are not a calibrator and cannot be utilized for calibration.
-
product
Proving Unit& Calibrators
Shanghai Beha Electronics Co., Ltd.
Calibration box is used to verify and proof any High Voltage Insulation Testers. It can be utilized to calibrate all High Voltage Insulation Testers very accurately Analogs or Digitals.
-
product
Electricians' Accessories
A selection of voltage detectors, proving units, test leads, certificate books and a DVD, which make it that bit safer and easier to get the job done.
-
product
Proving Units
Designed to suit a range of applications in the electrical contracting power utilities and industrial engineering sectors Seaward proving units are both self-powered and self-testing avoiding the need for a known supply point or bulky test equipment.
-
product
Proving Units for High Voltage Testing Equipment
A high quality range of proving units provide the important role of verifying the safe operation of high voltage potential indicators used by power engineers, maintenance personnel and service engineers. The proving units are essential tools for testing HV equipment before and after use.
-
product
Proving Unit
PRV240
The Fluke PRV240 provides a safe method to verify that your electrical test tool is operating properly before and after you conduct any live tests. The concept of “Test Before Touch” (TBT) involves testing your meter against a known live source before and after the actual measurement.
-
product
Insulation / Continuity Tester Proving Unit
PU250
The PU250 allows simple and quick check of insulation resistance and continuity for all makes of I/R testers.Regular checks outside of the formal calibration process are required for compliance with BS7671 and Part P.Proving unit to enable compliance to the requirement to maintain records of regular checks on the measurement characteristics and accuracy of test instruments.
-
product
H.V. Proving Unit (DCV)
2713 PU
Standard Electric Works Co., Ltd
● Designed to proof: -Phasing sticks. -High voltage detectors (contact type only, not to be used with non contact proximity detectors.) -High voltage and voltage testers.● Battery operated.● Led indicates when power is “ON”.● Small and hand-held.● Quick connection with normal 4mm test leads.
-
product
AC Voltage Proving Units
HLV-3
Standard Electric Works Co., Ltd
● Designed to proof. AC voltage detectors AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.
-
product
Test Voltage Indicators
PRV240FS
Verify your test tool works without unnecessary exposure to shock and arc flash. Make the process easy by using the PRV240FS Proving unit. Verifying that your T6 electrical tester is working properly reduces the need for personal protective equipment (PPE) when a known voltage source is not available for verification before tests are performed.
-
product
Proving Unit & Voltage Tester Kit
DLPK1
Touch electrode for Quick testing of fused leads Optical and acoustic continuity Indication Low battery indication A portable, battery powered Proving Unit for testing Two Pole Voltage Testers up to 690V Continuity Tester for testing: Fuses, Fused test leads etc
-
product
Digital Source Capture Unit
DIO2
The DIO-II module is a multimode digital source and capture unit. In Low Speed Mode it provides a 20-bit parallel or 24-bit serial I/O capability running at speeds up to 50 MHz. In High Speed Mode, the DIO-II provides a 16-bit parallel I/O capability up to 200 MHz. In both Modes, the Clock is generated by a low jitter PLL source that is capable of generating clocks from 320 kHz up to 1 GHz.
-
product
Source Measurement Unit
SMU32
The SMU32 is a low cost solution for V/I source and measurement. The SMU32 offers PMU/DPS in a compact, 3U PXI form factor. The SMU32 supports -1V to +10V +- 32 mA FVMI/FIMV modes. 8~32 PMUs can be ganged to DPS for high current driving.
-
product
21-Ch 6A-250VA 2-Bus Fault Insertion
YAV90077
21 channels 1 thread 6A 250V 2 Fault Insertion Buses Switching up to 250W CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
product
PXIe-4143, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit
782431-01
PXIe, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit - The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4143 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4143 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
product
PXI/PXIe Fault Insertion Switch, 74-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-012
The 40-190C-012 (PXI) and 42-190C-012 (PXIe) are fault insertion switches with 74 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 8 Channel
50-200-008
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
PXIe-4136, 200 V, 1 A System PXIe Source Measure Unit
783760-01
±200 V, 1 A System PXI Source Measure Unit—The PXIe‑4136 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4136 features 4-quadrant operation. The PXIe‑4136 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.
-
product
48-Ch 2A-250VAC 2-Bus Fault Insertion
YAV90076
48 channels2A 250V 2 Fault Insertion BusesSwitching up to 60CAN Control (or Ethernet with Ethernet to CAN Gateway)Drivers dll & VIs available
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
PXI Isolated Single Channel Voltage/Current Source, 100V
M9186A
The V/I source lets you source a voltage and measure the resultant current, or source a current and measure the resultant voltage. It consist of two separate amplifiers, denoted "low" and "high" that share a common output connection. The "low" amplifier provides voltages in the range of 16 volts at up to 200ma and the "high" amplifier provides voltages in the range of 100V at up to 20mA.
-
product
50 µs Pulse Medium Current Source/Measure Unit (MCSMU)
B1514A
The 50 s Pulse Medium Current SMU is an SMU designed for faster pulsed IV measurement. It enables a pulsed measurement down to 50 s pulse width, a 10 times or more narrow pulsed measurement than provided by a comparable conventional SMU. In addition, the instrument offers a wider range and versatility, up to 30 V / 1A, with voltage/current programmability. It is useful to characterize high to medium power devices on the new materials such as SiC and GaN, and organic devices, and the MCSMU expands your choices of pulsed IV measurement.
-
product
PXIe-4140, 4-Channel Source Measure Unit
781742-01
The PXIe-4140 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4140 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.
-
product
3U OpenVPX Sensor Interface Unit
SIU32S
The SIU32S is a highly configurable Modular Open Systems Approach (MOSA) rugged system or subsystem ideally suited to support a multitude of Mil-Aero applications that require high-density I/O, processing, communications and Ethernet switching. The SIU32S leverages NAI’s Configurable Open Systems Architecture™ (COSA®) 3U boards and smart function modules to deliver off-the-shelf solutions that accelerate deployment of SWaP-optimized systems in air, land and sea applications.
-
product
PXI Dual Bus 32-Chan 2A Fault Insert Switch
40-190B-202
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
42-190C-112
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch
40-190B-102
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI 34-Channel 4-Bus 2A Fault Insertion Switch
40-197A-001
This 34-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers. A low cost 16-channel option is also available.