Filter Results By:
Products
Applications
Manufacturers
-
product
Hall Effect Measurement system
HMS-3000
Hall Effect Measurement System is very useful for measuring Carrier Concentration, Mobility, Resistivity and Hall Coefficient that should be pre-checked in order to grasp the electrical specifications of semiconductor device. Therefore, it is essentially required system to understand the electrical characteristics of semiconductor device.Ecopia’s HMS series consist of constant current source , terminal conversion system by Van der Pauw technique, low temperature(77K) test system and magnetic flux density input system. So, it is well-established system that has all the things needed to Hall Effect Measurement System.
-
product
Handheld Gaussmeter
HGM09
Data storage on a personal computer via keystroke. The HGM09s is easy to use and has a good price/performance ratio. The handheld gaussmeter HGM09s is used to measure magnetic DC and AC fields. The measurands are flux density in Tesla or Gauss and the field strength in Amps per meter.
-
product
Probes for Tube Inspection
Probes for tube inspection are lightweight but solidly constructed eddy current, remote field, magnetic flux leakage, and IRIS ultrasound. These probes are used for ferromagnetic or non-ferromagnetic tube inspection applications.
-
product
Fluxmeters
Flux meter has been the established standard for the measurement of magnetic flux density for determining total flux in a magnet or magnetic assembly. Its use was curtailed except in a few specialized areas because of many factors such as the difficulty in setting up light beam flux meter or ballistic galvanometers, limitations on the ohmic resistance of search coils, the requirement of some degree of operator skill in reading the flux meter etc. The development of the integrating type Digital Flux meter has virtually cancelled the hitherto negative aspects of fluxmeterology and has found a broad niche for many magnetic measurement applications.
-
product
Motor/Gasoline Engine RPM Detector
OM-1500/1200
The OM-1500/1200 motor/gasoline engine RPM detector is designed for rotation measurement of a gasoline engine and an EV/HEV motor. It detects magnetic flux leakage from the motor itself or the engine’s ignition coil.This easy to use and durable detector can measure engine rotation by attaching in parallel with the ignition coil. When the EV/HEV motor rotation is measured, attach the OM-1500/1200 perpendicular to the motor rotating shaft.It is used with the engine tachometer by Ono Sokki (GE-2500, AR-7240B, CT-6520B, HT-6200, SE-1620, FT-2500, FT-7200).
-
product
Digital Flux Meters
Digital Fluxmeter is instrument made by electronic integration principle and displays the magnetic flux digitally. It can test magnetic materials. It not only measures flux but also directly tests magnetic performance for the purpose of quality control. With the features of legible display and convenient operation, it is an ideal device for flux measurement.
-
product
Fluxmeters
Hirst Magnetic Instruments Ltd
Fluxmeters for advanced measurements a Fluxmeter can be used to measure Magnetic Flux Linkage where a surface reading with a Gaussmeter is not sufficient.
-
product
Flux Meter
Star Trace Pvt. Ltd. is a renowned manufacturer and supplier of unbeatable quality Magnetic Field Flux Meters. The company manufactures these Magnetic Flux Meters from top-grade raw materials to ensure quality and performance. In order to ensure customers' satisfaction, these Magnetic Flux Meters are sent for several stringent quality control tests before supplying and exporting them to customers.
-
product
Polarity Tester
PT-1
International Electro-Magnetics, Inc.
The PT-1 provides a simple and easy way to determine the relative polarity of coil windings. It allows for an in-process test that takes a minimum of time to perform. By placing a coil on the platform and making connection to the start and end of a winding, a test signal is induced in the winding. The induced signal is low level and completely safe for the operator. By comparing the test signal phase of the coil under the test output, the relative polarity is indicated by the Red/Green LED. The tester operates by inducing a signal voltage in the coil under test by means of a magnetic flux field. The field is generated by a coil located in the probe base. The coil configuration is designed to provide optimum field distribution. We have also applied this basic circuit to a 5-channel scanning unit.
-
product
Helmholtz Coil
In the measurement of magnetic fields by means of Hall probes or measuring coils it is necessary to calibrate the instruments in a known magnetic field. Our standard field coil according to Helmholtzenables to production of a magnetic field calculable with high accuracy from the dimensions and the amperage. In series arrangement with an accurate ammeter field strengths of up to 800A/cm are produced. The dield room accessible both in axial and radial direction. Helmholtz coils with fluxmeters are also useful in testing of magnets. Helmholtz coils give repeatable results as against the search coils due to which the magnets can be compared with more accuracy for their total flux and in turn their quality. Field Generating and Field Detecting Helmholtz coils are designed as per user specifications.
-
product
Measuring Devices for Magnetically Hard Materials
WB10
The WB10 Fluxmeter is designed to measure the change of magnetic flux in measurements of magnetic properties of the magnetic materials in quasi-static and slowly floating conditions. Fluxmeter is the electronic measuring device with high sensitivity, very small drift as well as very small error of integration in a long time.
-
product
AC Magnetostriction Measurement Equipment
TLVM
This equipment measures quantitatively magnetostriction to indicate mechanical striction in magnetizing direction caused when magnetic steel sheet sample was alternately magnetized and is used for research and development of magnetic steel sheet. Magnetostriction is detected as speed signal through the parameters of magnetic flux density and compressive stress with laser doppler vibration meter.
-
product
Fluxmeter
480
The Model 480 is a laboratory grade fluxmeter, for use with a Helmholtz coil or custom search coils. This instrument measures the total flux of a magnet part, which can be related to the magnetic field strength. Applications include magnet testing, magnetizing, and automated field measurement. In order to provide accurate and repeatable measurements, automatic or manual drift compensation is available to the user. A peak mode allows even the fastest magnetic pulse, such as those from a magnetizer, to be accurately measured. The Model 480 is also useful for measuring AC fields that are too high in frequency for a gaussmeter to detect. Relay outputs and an external reset input allow for simple automation functions to be implemented, while the RS232C and IEEE-488 ports permit advanced control of the fluxmeter via a remote computer or automation equipment.
-
product
Wire Rope Detector
It adopts the method of magnetic flux leakage and magnetic flux, and uses the Ethernet high-speed transmission method, which can accurately complete the non-destructive testing of the wire rope in service.
-
product
Advanced Tachometer
FT-2500
FT-2500 advanced tachometer measures the rotational speed by using the signal of change in sound, vibration or magnetic flux from rotating machines such as motor or the like.The use of FFT technology enables the FT-2500 to calculate and display the rotational speed of any complex waveform signals from microphone, sound level meter or vibration sensor by extracting the frequency component which is equivalent to the rotational speed.
-
product
Magnet Temperature Characteristics Apparatus
TDF
Evaluation of thermal stability of varieties of permanent magnets including rare-earth permanent magnet. TDF-5-200auto This apparatus automatically measures and analyzes reversible temperature coefficient(a) and irreversible temperature coefficient (Flux loss ?f) of magnetic flux density of rare-earth permanent magnet in the wide range from low to high temperature.
-
product
Advanced Handheld Tachometer
FT-7200
The FT-7200 Advanced Tachometer is an easy-to-use handheld digital tachometer offering high functions and performance. The use of FFT (Fast Fourier Transform) technology enables the FT-7200 to perform frequency analysis of rotation speed by using change of signal in sound, vibration or magnetic flux from rotating machines such as a motor or the like. Selection from 5 kinds of measurement modes allows it to calculate and display rotation speed of any complex waveform signals from a sound level meter or an accelerometer accurately by extracting the exact frequency component.
-
product
Microprocessorized fluxmeter
MSM-101
Mobile meter designed to measuring the quasi-static changes of magnetic flux association with induction sensors. The minimal range of meter is equal 0.001Wb/V and drift under 7x10-6Wb/min.
-
product
Field Strength Measuring Instruments and Sensors
MAGNET-PHYSIK Dr. Steingroever GmbH
Field strength measuring devices are measuring devices for measuring the magnetic flux density B (formerly also called induction) and the magnetic field strength H of direct and alternating fields. They are also called Gaussmeters or Teslameters.
-
product
Digital Tesla Meter
HT208
Model HT208 digital teslameter is controlled by the SCM,which is suitable for handle operation.It can be used to measure DC or AC magnetic field and flux dencity.The device can be carried on one’sperson. It is characterized by its wide measuring range,simple operation and clear display. It is still added with the function of maintenance such as holding Measure Value/Peak Value,As mT or Gs unit of display can be change over,Measuring range of 200mT or 2000mT can be choosed,and others that as reseting zero by key and so on. The power is one piece of battery 9V. It can be used continually about 20 hours
-
product
Diesel Engine Tachometer
GE-2500
The GE-2500 diesel engine tachometer uses rotation speed of an alternator to measure engine rotation speed. With FFT calculation, this tachometer achieves reliable and stable measurement for both diesel and gasoline engines.The OM-1500 is a compact type detector designed for measuring rotation speed of an alternator. It detects magnetic flux leakage from an alternator. It is used to combine with the GE-2500. (The OM-1200 can also be used with the GE-2500.)
-
product
Zero Field Cavity
Zero field cavities generate a zero magnetic field in an air gap. They are mainly used to calibrate hall probes for their zero scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using Zero Field Cavity.
-
product
Magnetic Field and Permeability Measurement
MAGNETOSCOP® 1.070
Foerster Instruments, Incorporated
The MAGNETOSCOP 1.070 is a portable magnetometer system with microprocessor and probes for measuring the magnetic flux density as an absolute or differential value (gradient). It has a USB port for simple data transfer and an SD card for saving measurement data and parameters. The measuring system also facilitates the recognition and saving of peak values and the adjustment of thresholds for limit values. The unit can be used for series and individual measurements. The data can be easily analyzed and documented with the PC software included in the scope of delivery. The MAGNETOSCOP 1.070 thus facilitates the portable and fast measurement of the relative permeability within the scope of the quality control of stainless steel and low-permeable (non-magnetic) alloys as well as the localization of ferrite enclosures. Changes in material (sulfidation, degradation of lamination, structural changes) can also be proven thanks to permeability comparative measurements.
-
product
Search Coils And Field Measuring Coils
Designed to measure the magnetic flux on magnets or in the airgap of magnet systems.
-
product
Hall Effect Measurement system
HMS-3300
Magnetic flux density : 0.55Tesla (+/-0.03T)Gap distance between both round magnets : 26mm / Round magnet diameter : 50mmMeasurable temp : RT ~ 300℃(model# HT55T3). Resolution : 0.1℃(Model# HT55T5 : RT ~ 500℃)Both HT55T3 and HT55T5 are only capable of using with HMS-3000 main body.(Not compatible with HMS-5000 )- You can flow purge gas into small chamber and measure hall effect at the same time. Gas control valve can be installed as an option.
-
product
Gaussmeter/Teslameter
Model 2100
The Model 2100 Gaussmeter is a fully featured, high-end Gaussmeter with a low cost Gaussmeter price. It is a compact, high accuracy, microprocessor controlled, flux density measuring instrument. The Model 2100 is capable of measuring static (DC), alternating (AC), or pulsed magnetic fields. Twelve measurement ranges allow the operator to configure the meter for maximum resolution and accuracy from 300mG (30 microTesla) to 300 kG (30 Tesla). Selecting primary measurement functions is quick and easy with dedicated front panel function keys. An easy-to-use menu allows access to user defined parameters such as upper and lower magnetic limits and relative magnetic measurements. Remote meter configuration is completely accessible using the built in RS-232 Interface or optional IEEE-488 Interface.
-
product
D.C. Recording Fluxmeter
TRF
This is the equipment being able to measure direct current magnetization property of wide-ranging magnetic materials from soft magnetic materials to high performance permanent magnet with magnetic flux meter based on M integral closed magnetic circuit system.
-
product
Fluxmeter
480
An advanced tool designed primarily for use in industrial and measurement systems settings, the Model 480 fluxmeter measures total flux from which B, flux density, and/or H, magnetic field strength, can be determined.
-
product
Magnetic Flux Leakage Testing
PRÜFTECHNIK Condition Monitoring GmbH
NOVAFLUX - Flux Leakage Inspection for Black or Bright Steel Bars
-
product
Magnetic Material Test Fixture
16454A
The 16454A is designed for accurate permeability measurements of toroidal-shaped magnetic materials. Since the construction of this fixture creates one turn around the toroid (with no magnetic flux leakage), the need of winding a wire around the toroid is unnecessary. Complex permeability is calculated from the inductance with and without the toroid. When the E4991A/4291B with option 002 is used as the measurement instrument, direct readouts of complex permeability are possible. In addition, it is furnished with a small and a large fixture to adapt to a wide range of sizes.