Filter Results By:
Products
Applications
Manufacturers
MUX
Combine multiple signals into one signal.
-
product
PXI 20 Banks of 8 Channel 1 Pole MUX
40-615-022-20/8/1
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
product
PXI/PXIe MEMS Optical MUX, Quad 2-Channel, Single-Mode
40-855A-342
The 40/42-855A-342 is a PXI/PXIe quad 2-channel multiplexer with MU connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
product
PXI/PXIe MEMS Optical MUX, 4-Channel, Single-Mode, 9/125 Fiber, FC/PC Connectors
42-850A-114
The 40/42-850A-114 is a PXI/PXIe 4-channel multiplexer with FC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
product
Single 2 Channel Fibre Optic Mux Multi M
40-815-212-M
Pickering PXI Fiber Optic Multiplexers connect a single channel to one of two or four channels. They are available in single or dual multiplexer configurations supporting single-mode or multi-mode fiber. A wide choice of connectors types is available. The 40-810 multiplexer connects the optical channel by redirecting the optical signal into a selected output fiber.
-
product
Control and Switch Modules
Mini Mux
Eclypse International Mini Mux Control and Switch Modules, plus Software Developer Kit (SDK) provides high density test circuit switching as a complement to the Eclypse Circuit Analyzers. The Mini Mux Switching gives the user the ability to test continuity and isolation in complex assemblies with thousands of circuit paths (such as avionic back planes and chassis), while minimizing the test equipment complexity and footprint.
-
product
PXI MUX 4 Banks of 16 Channel 2 Pole
40-610-022-4/16/2
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
product
PXI/PXIe MEMS Optical MUX, 8-Channel, Single-Mode
40-852A-318
The 40/42-852A-318 is a PXI/PXIe 8-channel multiplexer with MU (mini SC) connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
product
PXI 5A Mux 4-Bank 11-Ch Isolated COM
40-651-013
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel.Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
product
PXI 2 Amp Multiplexer, Dual 8-Channel, 2-Pole
40-635A-106
The 40-635A-106 is a dual 8-channel, 2-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
product
PXI Dual 4 to 1 RF Multiplexer 3GHz 50 Ohm MCX Terminated
40-876-102
The 40-876-102 is a 50 Ohm 4 to 1 RF multiplexer with 2 banks in a single PXI slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The injection of noise and unwanted signals into the signal paths of the 40-876 has been minimized by careful attention to the mechanical and electrical design.
-
product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 62.5/125 Fiber
40-852A-118-M62.5
The 40/42-852A-118-M62.5 is a PXI/PXIe 8-channel multiplexer with FC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
product
4x (1 to 4) +1x (4 to 1) 50 Ohm 2.5 GHz RF Multiplexer with Self Test Relays
YAVAL022
5x (1×4) Mux + 2x Pass trough Selftest function 30Vac/dc, 10W Max Max current 500mA Reflexive
-
product
PXI MUX 8 Banks of 8 Channel 2 Pole
40-610-022-8/8/2
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode
40-850A-214-M50
The 40/42-850A-214-M50 is a PXI/PXIe 4-channel multiplexer with SC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
PXI Solid State Multiplexer Module, Dual 3-Channel, 30 A, Hardware Interlock
40-667C-011-HI
The 40-667C-011-HI is a dual 3-channel 30A MUX with hardware interlock and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation.
-
product
PCI 2 Amp Multiplexer, Single 4-Channel, 8-Pole
50-635A-104
The 50-635A-104 is a single 4-channel, 8-pole MUX and is part of a range of PCI Multiplexer cards available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
LXI Dual 8:1 Optic MUX SC/PC Loop-Thru
60-850-222
The 60-850 and 60-851 are LXI conformant fiber optic multiplexers that use MEMS switching technology to ensure fast and reliable switching of single-mode (60-850) or multi-mode (60-851) optical signals being carried on fiber connections. The 60-850/851 is available with a variety of connector options and in a variety of multiplexer arrangements. Loop-thru versions are also available for easy multiplexer expansion.
-
product
PXI MUX 8 Banks of 16 Channel 1 Pole
40-610-022-8/16/1
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
product
PXI High Density MUX BRIC, 24-Chan, 20-Pole
40-570-313
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
product
PCI 2 Amp Multiplexer, Single 8-Channel, 4-Pole
50-635A-103
The 50-635A-103 is a single 8-channel, 4-pole MUX and is part of a range of PCI Multiplexer cards available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
PXI/PXIe RF Multiplexer, Dual 4-Channel, 3GHz, 75Ω, SMB
42-832A-002
The 40-832A-002 (PXI) and 42-832A-002 (PXIe) are 75 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The design of the 40/42-832A minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.
-
product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 50/125 Fiber
40-852A-518-M50
The 40/42-852A-518-M50 is a PXI/PXIe 8-channel multiplexer with ST connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
product
PXI High Density MUX BRIC, 12-Chan, 80-Pole
40-570-116
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
product
4x (1 to 4) +1x (4 to 1) 75 Ohm 2.5GHz Mux
YAV91750
4x (1×4) Mux + 2x Pass trough30Vac/dc, 10W MaxMax current 500mACAN Control (or Ethernet with Ethernet to CAN Gateway)Reflexive
-
product
PXI/PXIe RF Multiplexer, Single 8-Channel, 3GHz, 75Ω, SMB
42-834A-001
The 40-834A-001 (PXI) and 42-834A-001 (PXIe) are 75 Ohm 8 to 1 RF multiplexers with 1 bank in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
product
PXI Single 6-Channel 30A Solid State MUX
40-667-012
The 40-667 is a high current multiplexer available in dual 3-channel or single 6-channel configurations occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 30A of continuous current and switch up to 40V signals. The switches can sustain inrush currents in excess of 120A. AC or DC signals can be switched since the switch is polarity insensitive.
-
product
PXI High Density MUX BRIC, 3-Chan, 160-Pole
40-570-013
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
product
PXI/PXIe RF Multiplexer, Dual 4-Channel, 3GHz, 50Ω, SMB
40-872A-002
The 40-872A-002 (PXI) and 42-872A-002 (PXIe) are 50 Ohm 4 to 1 PXI RF multiplexers with 2 banks in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
product
PXI 5A Power MUX, 4-Bank, 11-Channel
40-651-003
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel.Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
product
PXI 2 Banks of 40 Channel 1 Pole MUX
40-615-021-2/40/1
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.