Filter Results By:
Products
Applications
Manufacturers
Load Banks
Test a power source by providing controlled amounts of load to create conditions found in thier application.
See Also: AC Load Banks, DC Load Banks, Inductive Load Banks, Reactive Load Banks, Resistive Load Banks
-
product
Battery Testing System
C8000
The Cadex C8000 stands in a class by itself in flexibility and affordable price. Test SMBus batteries, monitor cell balance and capture load signatures to observe batteries with a unique load protocol. Add a thermal chamber, an external load bank, a safety circuit and alarm to form a command center and you begin realizing the unique qualities of this fine battery testing system.
-
product
Radiator Mounted Load Banks
RD-Series
RD-series radiator mounted load banks are designed to be fitted directly onto diesel generator sets. RD-series load banks use the engine cooling air from the generator radiator to cool the load elements.
-
product
AC Load Bank (Resistive)
K-1000 Resisitive
Kongter Test & Measurement Co., Limited
The kW of a resistive load bank is “real” power in electrical terms. When a resistive AC load bank is used to test an engine generator set the engine will produce its full horsepower rating, dissipate engine exhaust gases, and produce thermal energy into the engine cooling system. The resistive load bank in fact, will completely test the engine and its various systems.
-
product
Load Bank
Being the reckoned names in the industry, we offer world-class range of Load Bank that is manufactured with perfection. We offer in different configurations such as Resistive, Inductive, and Capacitive. Our entire product range has high compressive strength and ensures smooth operations. They are durable in nature and are delivered in stipulated time frame.
-
product
AC Load Bank (Rack Mounted)
K-1000 Rack Mounted
Kongter Test & Measurement Co., Limited
Rack mounted resistive load bank is widely used in data center to simulate electric loads and dissipation of IT systems. These load banks are controlled by sectional steps with customized setting. Users could set power and time as per their needs with easy operation.
-
product
Multi-Unit Controllers
Mosebach Manufacturing Company
Mosebach’s Multi-Unit Controllers are built to help you manage your load banks in operation – whether 10, 20 or 500 units ganged together.
-
product
Custom Load Banks
Power House Manufacturing, Inc.
Custom Load Banks are our specialty. Power House Manufacturing is dedicated to providing our customers with exactly what they need. Having years of custom load bank manufacturing experience, Power House can deliver the perfect custom testing solution you require.
-
product
SMART Constant Current DC Load Banks
SLB-Series
SMART Constant Current DC Load Banks are designed for acceptance testing, discharge testing, battery capacity testing, battery maintenance, engineering examination and other testing for DC power with load. The SMART technology allows a constant current discharge without the need for manual adjustment of current during the discharge test. Our SLB-Series load banks are portable, durable, economic, safe, easy-to-use and come complete with our DataView software, providing the user with a complete data management and analysis program.
-
product
AC Load Banks
X100L Series
Mosebach Manufacturing Company
Introducing Mosebach’s X100L load bank. One of the lightest dual voltage, 100 kW load banks on the market! The unit weighs approximately 64 lbs. and has 5 kW resolution. The X100L load bank includes an Industrial strength, injection molded, 100% water proof case with wheels as shown below.
-
product
AC Load Banks
X60C Series
Mosebach Manufacturing Company
The X60C is a small suitcase style 60 kW load bank.
-
product
Rack Mounted Load Banks
Traditional commissioning is a daunting task. Since formal system operation doesn’t begin until the system is commissioned, the commissioning team experiences intense pressure to complete the commissioning process quickly. Commissioning can involve high expense and requires staffs from different departmental disciplines to work together. For these reasons data center commissioning has almost uniquely been associated with large data centers (over 20,000 ft2 or 1,858 m2). In the recent past, many data center managers chose to roll the dice and perform little or no commissioning, relying only on start-up data to press ahead with launching the new data center. Given the reality of 24x7 operations, however, the alternative of exposure to major system failures and accompanying downtime is no longer an economically viable option. Commissioning has now become a business necessity. JUNXY series AC & DC rack mounted load banks can be used to introduce heat loads and to allow for simultaneous testing of both electrical and cooling systems.
-
product
Load Banks
PARELO
Amfax introduce the latest generation of load banks we affectionately call PARELO. This range of load banks provides a combination of high performance passive resistive loads along with extreme flexibility of use. This is achieved by our unique FLEXI-phase Switching(TM) technology.. Designed primarily for offering high wattage loads for the aerospace, energy, automotive and transport sectors. PARELO load banks are a cost effective solution for companies requiring high wattage loads when testing their products.
-
product
Variable Resistor Load Bank
REOLOAD 100
A variable resistor load-bank with fixed stages connected in parallel and switched in, as required, with an adjustable stage for fine trimming. Designed for testing equipment under load. 1000V (AC or DC). 250A and 2500
-
product
AC Load Bank (Resistive/Capacitive)
K-1000 Resistive/Capacitive
Kongter Test & Measurement Co., Limited
A RCD (resistive/capacitive) generator load bank is non-linear load bank. The electronic and non-linear loads simulated by capacitive load banks are typical of the Telecommunications, Computer or Uninterruptible Power Supply (UPS) Industries.
-
product
Amplifier Dyno
AD-1
The AD-1 Amplifier Dyno is a tool that is designed to be used any place an amplifier exists. It can be used in a lab or production line to test true amplifier power output, quickly and easily. It is simple menu driven, does not require a computer, and cannot be cheated as the load banks are internal. It can be used in an automotive audio install shop to test true amplifier output while the amplifier is installed in the customer's vehicle.
-
product
Battery Load Bank
Foresight Electronics Co., Ltd.
Utility is used for battery systems range from 21-30V, if higher current is needed, two or more FST-24V units can be linked together. Discharge to Battery string voltage as 24V, Cell voltage as 1.2V/2V/6V/12V adjustable stop points and multiple alarm designs to control the discharge process intelligently 7inch LCD touch screen for easy operation and showing various parameters real time Support RS232 real time monitoring by PC or SD Card download data after discharge
-
product
Load Banks
EL Series
*12kW, 15kW and 18kW DC Electronic Load*All of our Load Banks are continuously rated for Power and Current.
-
product
AC Load Banks
XL1500 Series
Mosebach Manufacturing Company
The XL1500 Series of resistive load banks are designed for testing power supplies up to 1500kW of various voltages.
-
product
PXI Single 18 Channel MUX, BNC Connectors
40-735-902-S3
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
product
Locomotive Testing
DC7000
A purpose-built load bank for the performance testing of engines and generators of all types of diesel electric locomotive up to 4000hp rating, with easy-to-use resistance adjustments allowing tests to be carried out over the whole power envelope. Capacity 0 7000A continuously at up to 2000V DC
-
product
Resistive & Inductive AC Load Bank
RL
Resistive & reactive load banks are able mimic motor loads and electromagnetic devices within a power system as well as purely resistive loads by offering the ability to set a specific power factor (pf). Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit. JUNXY has an extensive range of resistive & reactive load banks to simulate these types of loads on a power source and the transformers, relays, and switches which will distribute the power throughout your facility.
-
product
PXI 18 Channel Data Comms MUX, 96-pin SCSI
40-735-902
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
product
AC Load Banks
X250S Series
Mosebach Manufacturing Company
The X250S is the only one of its kind: 250 kW in a very small package. Light, portable; with digital meter and recording capability. Center lifting bar and casters are both available as options. Ideal for "Black Tests" in data centers as blowers are powered externally with 120VAC
-
product
Battery Load Bank
K-3980
Kongter Test & Measurement Co., Limited
Kongter offers a series of customized DC load banks with many different models for constant current battery discharge test and battery capacity test. They cover a wide voltage range from 12V to 480V nominal voltages with current up to 600A. They are widely applied in various industries. With its optional battery Data Acquisition Case (DAC), discharge values of EACH cell could be monitored in battery load bank and PC software simultaneously by using Kongter’s data view software.
-
product
Portable Power Quality Analyzer
PDA 1252
The PDA 1252 is a portable power quality analyzer designed to monitor, isolate and troubleshoot power system disturbances. Using our advanced analysis software, the Communicator EXT application, view real time data presented in a simple and powerful format. Maximize the Communicator EXT application's power with the optional AiReports to generate disturbance solutions and advanced power reports. The unit is ideal for load surveys, program, monitoring transformer banks and indoor/outdoor electrical monitoring. The PDA 1252 Power Quality Analyzer is mounted in its own watertight carrying case and uses watertight connectors to connect voltage and current leads. Based on the Nexus 1252 platform, the PDA 1252 is easy to use and operate.
-
product
AC Load Bank
AC-LB-Series
Eagle Eye AC Load Banks are commonly used for testing generator sets, UPS units, aircraft power inverters and other government and military AC power sources. The Eagle Eye AC LB-Series is the smallest in the industry and offers unmatched durability in even the harshest testing environments. Eagle Eye offers several standard models as well as custom AC Load Banks.
-
product
Anti-Islanding Load Banks
AI-Series
AI-series anti-islanding load banks containing purely resistive, inductive, or capacitive load, have segmented combination control of power input, and can simulate a variety kinds of power loads to meet the grid-connected inverter full load test requirements.
-
product
Battery Load Banks
Kongter Test & Measurement Co., Limited
Kongter offers many different models of battery load units for real capacity test in various industries. With our customized solution, users of different applications will find their exact models as per their needs. With its optional DAC (Data Acquisition Case), you could easily monitor voltage of each cell on PC during battery discharge test.