Filter Results By:
Products
Applications
Manufacturers
Jitter
Unwanted signal deviation.
-
product
Oscilloscope 33 GHz, 4 Channels
UXR0334B
UXR0334B Infiniium UXR-Series is the 33 GHz, 4 channel, Infiniium UXR-Series real-time oscilloscope, that offers 10-bit high-definition ADC, 20 femtoseconds (typical) of intrinsic jitter for exceptional jitter characterization.
-
product
WaveMaster Oscilloscope, 8 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate
WaveMaster 808Zi-B
Up to 20 GHz bandwidth and 80 GS/s sample rate.The most advanced oscilloscope user interface.The industry’s only true hardware 14.1 Gb/s serial trigger.Low Jitter Measurement Floor and exceptional timebase stability.Comprehensive set of serial data analysis, debug, validation and compliance tools.Integrated 50 Ω and 1 MΩ inputs for true connection and probing flexibility.Integrated standard and custom measurements and math functions for unrivaled analysis capability.Multi-lane serial data eye, jitter and crosstalk analysis.Real-time de-embedding, emulation, and equalization.
-
product
SDI Reclockers
Macom Technology Solutions Holdings Inc.
MACOM’s reclockers are specifically designed to help build robust video broadcast systems by removing jitter from Serial Digital Interface (SDI) video signals. These multi-rate products are essential when designing high definition (HD) and ultra high-definition (UHD) systems that are compliant with the Society of Motion Picture and Television Engineers (SMPTE) standards.
-
product
Computer-Based Instruments
GT210PCI
with the GT210PCI you can determine any frequency to 0.01 part per million (eight digits) in just 1 mS, and resolve each time measurement to 8pS. Couple that with 2300 measurements per second, one of the fastest rates available and you can acquire more data in a single second than a typical GPIB counter can in one minute! Faster measurements and higher resolution, along with built-in statistics functions give you a more thorough analysis of your signal. Standard deviation, peak to peak jitter, or a graph of the measurements are available at the push of a button.
-
product
Transimpedance Amplifiers
Advanced Science and Novel Technology, Co., Inc.
Broadband transimpedance amplifier for low noise receiver side applicationsFeatures automatic input offset control and a peak detector8GHz of analog bandwidth for limiting of input data60dB of transimpedance differential gain15pA/sqrtHz of input referred noise density (0.1 to 10GHz)CML output interface with 50 termination and 225mVp-p single-ended swingSingle +3.3V power supplyPower consumption: 250mWExhibits low jitter and limited temperature variation over industrial temperature rangeUnpackaged bare die
-
product
Pulser / Sampler Core
Furaxa has researched, developed, and characterized a novel monolithic arrayable pulse and sample aperture generation technology. Recent results include demonstration of sub-10ps pulse/aperture generation at repetition rates up to 3 Billion Pulses/Samples Per Second (BPPS) with jitter that is estimated at sub-10fs. Further, simulations in a number of InP DHBT processes exhibit sub-3ps 20BPPS performance. The IP is process-independent, and has been achieved in CMOS SOI, InP HBT, SiGe and GaAs so far. Please contact us regarding your specific foundry and technical requirements: The company currently licenses the sampler/pulser technology for use by application and market, and is interested in discussing how the technology can enable our partners' applications. A short list of characterized Pulser/Sampler Cores is given below.
-
product
Digital Storage Oscilloscope
SDS6000A
The SDS6000A series employs Siglent’s SPO technology with a maximum waveform capture rate of up to 170,000 wfm/ s (normal mode, up to 750,000 wfm/s in Sequence mode), 256-level intensity grading display function plus a color temperature display mode. It also employs an innovative digital trigger system with high sensitivity and low jitter. The trigger system supports multiple powerful triggering modes including serial bus triggering. Tools such as History waveform recording, Search and Navigate functions, Mask Test, Bode Plot, Power Analysis, and Eye/Jitter Analysis allow for extended waveform records to be captured, stored, and analyzed. An impressive array of measurement and math capabilities, options for a 25 MHz arbitrary waveform generator, as well as serial decoding are also features of the SDS6000A Digital Oscilloscope.
-
product
Real-time IP network measurements
IPProbe
Real-time network measurements for multiple IP interfaces. Detection of Packet loss, IAT (Inter Arrival Time), Delay, Bitrate and ETR290 problems. Stable packet generation and receiving is a key feature required in any modern IPTV environment. Any irregularity and/or discontinuity in this packet stream means buffering problems or losing frames. IP jitter provides a means to see the distribution and stability in the IP stream.
-
product
Jitter Free I/O Access Fast Data Acquisition
TiCoBasic
Shortest available reaction time for fast data acquisition, open- and closed-loop control! This focus of Jger Messtechnik is greatly intensified by the new TiCo processor, which enables real-time processing in the scale of nanoseconds. The TiCo (Timing Controller) being implemented into a Xilinx FPGA enhances the approved ADwin systems by a close-to-I/O, extremely fast pre-processing.
-
product
PCI BUS Interface Card
PCI301
MIL-STD-1553 A, B & McAir MULTI PROTOCOLS Simulator/Analyzer/Tester PCI BUS Interface Card - The PCI301 can be used for Validation Testing, Production Testing, full bus simulation and monitoring, as a general purpose 1553 interface or a stand alone bus Analyzer. For precise message scheduling and measurements, the Major and minor frame times are independent of message sequences or retransmissions on errors and the start of all command messages are independent of message length, response time or length of response. Message timing is calibrated and RT responses have low jitter.
-
product
Infiniium V-Series Oscilloscope: 8 GHz, 4 Analog Channels
DSOV084A
8 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with low noise floor (1.04 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
product
Adjustable Length Linear Backlight, 300 mm to 2100mm
Vitech A1905
Modules A1905 are designed for pulsed or continuous illumination of objects in machine vision systems. The time of ignition (90%) and blanking (10%) of the module is less than 1 μs with jitter of the front (jitter) no more than 2 μs, which allows the modules to be used for exposure with "slow" cameras.
-
product
Function/Arbitrary Waveform Generators
SDG5000 Series
Siglent Technologies invented the pulse generator algorithm EasyPulse, which is found in the SDG5000 waveform generators. Based on this new technology, the SDG5000 is capable of generating a pulse signal with low jitter, fast rising and falling edge (frequency independent effect), small duty cycle, edge and pulse width can be a wide range of adjustment.
-
product
MPI PCB Probe Systems
MPI Advanced Semiconductor Test
Every MPI manual probe systems can be configured with a variety of different holders for printed circuit boards (PCB’s) in order to provide in addition to on-wafer, versatile, convenient, and accurate Signal Integrity (SI) measurements with single-ended or differential RF probes. Measuring signals at the end of the channel for eye-patterns, deterministic jitter, distortion, TDR (Time Domain Reflectometry) impedance, cross-talk, coupling, and losses, or even S-parameters is easily accomplished.
-
product
TDR Probe
TDP Blade Probe
The TDP Blade Probe enables fast and convenient TDR measurements and debugging. The BladeProbe tips are made from strong and rigid beryllium copper blades for handheld and probe station probing. The passive probe can be used to measure impedance, clock jitters, and skews. The TDP BladeProbe series can be connected to TDR, high performance scopes, and vector network analyzers.
-
product
Infiniium V-Series Oscilloscope: 20 GHz, 4 Analog Channels
DSOV204A
20 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.54 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
product
Infrared Video Processing
*Edge Enhancement improves the apparent sharpness of an image by boosting the contrast of edges in the imagery *Electronic Image Stabilization compensates for jitter in a video sequence, providing stabilized video output and remaining responsive to intentional user panning*Auto-Focus automatically adjusts the lens focus to its optimal in-focus position *Electronic Zoom uses interpolation to produce an enlarged image on the video display *Non-Uniformity Correction compensates for detector-to-detector non-uniformity to provide a well-calibrated image output
-
product
Clock & Data Recovery
Macom Technology Solutions Holdings Inc.
Macom offers a series of high-performance, flexible, clock-and-data recovery (CDR) devices to remove the jitter from signals in high data rate systems. Our family of CDRs spans from 10Gbps to 100Gbps per lane in multitude of configurations including single lane and multi-lane devices, standalone CDRs and integrated combo devices with TIA and laser drivers. This wide portfolio of configurations offers customers design flexibility and cost-optimization in systems for Ethernet and OTN based network infrastructure markets and extending to high performance computing, storage-area-networking (SAN), industrial and aerospace applications.
-
product
Pulse Pattern Generator, 3.35 GHz, dual-channel
81134A
When timing and performance requirements are critical, for example in high-speed serial bus applications like PCI Express or Serial ATA, its fast rise times and low intrinsic jitter allow the precise and in-depth characterization of devices, e.g. receivers or backplanes. On top of that, it allows to generate application-specific signal levels like pre- and de-emphasis (PCI Express) or squelch (Serial ATA). The Keysight 81134A lets you test your DUT instead of the pulse or data source!
-
product
High Performance Smart Spectrometer
Exemplar Plus
The Exemplar® Plus is a high performance smart spectrometer utilizing a low stray light unfolded Czerny-Turner spectrograph. It features a highly sensitive TE Cooled back-thinned (BT) CCD detector which is linearly summed for high dynamic range. Its long focal length, coupled with a high quantum efficiency detector, provides superior data quality over the entire 190-1100nm spectral range. The Exemplar Plus features a high signal to noise ratio, making it ideal for low light level applications, and also features a built-in shutter allowing for dark scan measurements, even while illuminated. As a member of the Exemplar product line, it features on board data processing and USB 3.0 communication. The Exemplar product line is also optimized for multi-channel operation featuring ultra-low trigger delay and gate jitter.
-
product
DAQ Module
FMC-DAQ2P5
Sundance Multiprocessor Technology Ltd.
ADC12J2700 – 12bit 2.7GSPS JESD204B.LM95233 for ADC temperature monitoring.JESD204B via HPC connector, 8 lanes 5.4Gbps per lane.AD9136 – 16-bit dual channel 2.8GSPS JESD204B DAC.HMC7044 – High performance 3.2GHz JESD204B jitter attenuator.
-
product
Quality Of Service
Traffic is prioritized according to its importance and some types of traffic are more sensitive to latency, jitter and packet loss than other. Xena offers QoS validation solutions in accordance with RFC 2544 and Y.1564, as well as advanced statistics functions that help users track, analyze and troubleshoot QoS to maintain a high service quality guarantee. Testing that link performance complies with a Service Level Agreement (SLA) includes verifying Frame Transfer Delay (FTD), Frame Delay Variation (FDV) and Frame Loss Ratio (FLR) at the Committed Information Rate (CIR) defined in the SLA. Verifying the SLA with the Xena1564 allows doing the test on a line simultaneously loaded with traffic from other services.
-
product
Function/Arbitrary Waveform Generators
SDG2000X Series
SIGLENT’s SDG2000X is a series of dual-channel function/arbitrary waveform generators with specifications of up to 120MHz maximum bandwidth, 1.2GSa/s sampling rate and 16-bit vertical resolution. The proprietary TrueArb & EasyPulse techniques help to solve the weaknesses inherent in traditional DDS generators when generating arbitrary, square and pulse waveforms. With advantages above, SDG2000X can provide users with a variety of high fidelity and low jitter signals, which can meet the growing requirements of complex and extensive applications.
-
product
LXI WTB Terminator, 90.6 ohm
60-983-002
The 60-983 is an LXI compatible Wired Trigger Bus Terminator (WTB) designed to be attached to the end of a WTB cable. The LXI WTB uses a transmission line cable to connect LXI devices together that support the WTB capability of the LXI standard. Like all transmissions it needs to be correctly terminated to avoid reflections that could change the signal amplitude along the cable and generate timing jitter or trigger errors. The 60-983 is a simple terminator that can be placed at each end of the WTB chain to correctly terminate the transmission line with minimal reflections.
-
product
Super Phosphor Oscilloscopes
SDS2000X-E Series
The SDS2000X-E series employs a new generation of SPO technology. With its excellent signal fidelity, background noise is lower than similar products in the industry. It has a minimum vertical input range of 500 uV/div, an innovative digital trigger system with high sensitivity and low jitter, and a waveform capture rate of 400,000 frames/sec (sequence mode). It also employs a 256-level intensity grading display function and a color temperature display mode not found in other models in this class. Siglent’s newest oscilloscope offering supports multiple powerful triggering modes including serial bus triggering and decoding. History waveform recording and sequential triggering allow for extended waveform records to be captured, stored, and analyzed. Also included is the deep memory FFT. This math function uses upto 1 M samples for the FFT calculation, providing the SDS2000X-E with very high frequency resolution. The hardware co-processor executes true fast measurement and math to all of 28M sample points so that there is minimal distortion on analysis. It also supports searching and navigating, on-screen Bode plot, 16 channel digital /MSO (optional), an external USB powered 25 MHz AWG function generator module (option), a USB WIFI adapter for wireless control and monitoring (option), and an embedded application that allows remote control via web browser. The features and high-performance of the SDS2000X-E oscilloscopes cannot be matched else anywhere at this price.
-
product
Infiniium V-Series Oscilloscope: 8 GHz, 4 Analog Channels
DSAV084A
8 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.04 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
product
32-Axis PCIe EtherCAT Master Motion Controller
PCIe-8334
ADLINK PCIe-8334 is a hardware-based EtherCAT motion controller able to support up to 32 synchronized axes and over 10,000 points simultaneously. The PCIe-8332 features dedicated isolated emergency stop input (EMG), and configurable isolated high-speed digital input as not only generic sensor input but also pulsar input, with up to 1MHz input frequency. Optimum jitter control is provided in minimal cycles of 250µs to optimize synchronous I/O performance for vertical automation applications in semiconductor, electronic manufacturing, and others. The PCIe-8334 provides an out-of-shell application-ready (APS) function library to generate multi-dimensional, highly synchronized, time-deterministic event-triggered motion & I/O control. A wide range of compatible 3rd party slaves are easily designed with ADLINK's APS function library. ADLINK's MotionCreatorPro 2 utility is fully compliant with the Microsoft Windows environment, that allows complete EtherCAT motion and I/O configuration and function evaluation as well as compiling program download functions.
-
product
Clock Distribution Devices
Analog Devices offers ultralow jitter clock distribution products that fan out given signals for wireless infrastructure, instrumentation, broadband, ATE, and other applications demanding subpicosecond performance. Our clock products are ideal for clocking high performance analog-to-digital converters (ADCs) and digital-to-analog converters (DACs). ADI clock ICs integrate PLL cores, dividers, phase offset, skew adjust, and clock drivers in small chip scale packages.
-
product
GL Products Online & Interactive Demos
*NetSurveyorWeb™ is a centralized VoIP network monitoring system. A number of GL's PacketScan™ probes and/or,PacketProbes™ are deployed in remote locations across the network to passively monitor VoIP traffic. Whenever a monitored call completes, the scan/probe calculates a variety of quality metrics (MOS, loss, delay, jitter, etc) and sends the metrics to the central Oracle database for storage.**The PacketScan™ is a feature-robust Windows® based software tool that captures and monitors live IP traffic. In the VoIP world, it can monitor and measure SIP, H323, Megaco, MGCP, T.38 and video calls. In addition to quality metricsPacketScan™ also captures signaling information and sends that to the NetSurveyorWeb™ database as well.**GL's PacketProbe™ is an advanced CPE(Customer Premises Equipment) based VoIP monitoring reporting and diagnostic appliance, stemming from GL's suite of market leading voice analysis tools.
-
product
Infiniium V-Series Oscilloscope: 13 GHz, 4 Analog Channels
DSAV134A
13 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.09 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)