Filter Results By:
Products
Applications
Manufacturers
-
product
High Frequency Current Transformer
HFCT Ø 140mm
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
product
Auxiliary Potential Transformers
Osborne Auxiliary Potential Transformers (Aux PT’s) are used in utility and commercial industrial power systems. Osborne works with our clients to identify the safety advantages of using auxiliary potential transformers (Aux PT’s) to establish protection schemes for high voltage equipment. Aux PT’s step the voltage down to safer levels, normally below 600 V AC.
-
product
903 Benchtop Three Phase 40A
Weshine Electric Manufacturing Co., Ltd
1. The instrument has standard four phase voltage and three-phase current output. It can test not only various traditional relays and protection devices, but also various modern microcomputer protections, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. Classic Windows XP operation interface, friendly man-machine interface, easy and fast operation; high performance embedded industrial control computer and 8.4 inch resolution 800 × 600 TFT true color display screen, can provide rich and intuitive information, including the current working state of the equipment and various help information.
-
product
High Quality Transformer Oil Dielectric Strength Tester
AS-023A
Chongqing Assen Power Equipment Co., Ltd
AS-023A Series High Quality Intelligent Transformer Oil Dielectric Strength Tester is specially designed for testing dielectric strength (Breakdown Voltage) of transformer oil. The breakdown voltage (dielectric strength) is one of the most important parameters of transformer oil, it is a rule of the voltage withstand. The value of breakdown voltage (dielectric strength) indicates whether the oil contains water, impurity and electric particles, and you’ll know the oil value via the breakdown voltage (dielectric strength).
-
product
Transformer Turns Ratio Meter
TTRM 102
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
product
Injection Transformer
J2100A
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
product
1μΩ-4kΩ AC Milliohmmeter Low Resistance Tester
TH2521
Shenzhen Chuangxin Instruments Co., Ltd.
TH2521 AC Milliohmmeter is a high-performance and intelligent tester widely used to test contact resistance, internal resistance and battery voltage. The application of constant current source with 1kHz frequency can greatly eliminate the potential error caused by thermoelectricity on DUT. This meter has the function to automatically detect contact failures on test cable. At the range of 30mΩ, basic R resolution can reach 1μΩ. It is applicable for transformer, inductance coil copper resistance, relay contact resistance, switch, connector contact resistance, wire resistance, PCB line and via reistance dan metal defect detection, etc. In the mean time, signals, such as HIGH, LOW, PASS, can be output through HANDLER interface, thus it is very convenient to be used in automatic production line.
-
product
Digital Fault Recording
SHERLOG
Fault recorder systems with a power quality analyser for comprehensively monitoring and assessing low, medium and high voltage networks in power plants and transformer substations. The measuring devices of the SHERLOG range make very high-resolution recordings of all the disturbances which occur in power supply systems. The behaviour of protection and switchgear devices during these system disturbances is recorded at the same time.
-
product
Advanced Handheld Partial Discharge Detector for Electric Power Equipment with Multi-Sensor and Cloud Diagnostic Technologies, Data Management Software, and Test Management App
PDetector
Power Monitoring and Diagnostic Technology Ltd.
The PDetector is an ideal device for On-Line Partial Discharge (OLPD) testing of MV and HV equipment which employs all 5 types of OLPD sensor technology: Ultra-High Frequency (UHF), Acoustic Emissions (AE), Ultrasonic, High Frequency Current Transformer (HFCT), and Transient Earth Voltage (TEV). The information from multiple sensors gives the PDetector the versatility to detect all types of PD in all types of substation apparatus. The exact type of PD activity can be determined effectively using multiple on-screen data spectrum analysis. The PDetector greatly simplifies and standardizes the routine OLPD testing procedure by using the Intelligent Patrol function, the PDetector App, and the PMDTCloud. It is a very powerful and helpful tool for substation operators to conduct routine testing in a substation quickly, to determine what the issue is, and where it is located.
-
product
Transformers
RR Enterprises provides all type of transformersSingle Phase and Three Phase upto 100 KVA.The transformers can be→ Air Cooled→ Epoxy Cast→ Oil CooledWe provide transformers in high voltage and low voltage. These are used for various industrial and research purposes.→ High voltage transformers for corona and static elimination.→ High voltage transformers for plasma welding.→ Special purpose high voltage transformers.→ High current transformers for metalissing plants.→ Special purpose high current transformers.
-
product
High Impedance Transformers
Osborne high impedance transformers are used to step-up, step-down and isolate voltages in single phase and three phase circuits. A properly designed high impedance transformer can be used an an equivalent to an isolation transformer connected in series with an inductor. The high impedance characteristic may be employed as a current limiting feature in both the primary and secondary circuity.
-
product
High Voltage Test Set
Hi-Pot Series
SCOPE introduces a high voltage test set, these high voltage testing sets comes with Power frequency AC high voltage /DC high Voltage test /AC-DC high Voltage test set for testing transformers, motors, insulators, cables etc. Further, these testing sets are capable of giving continuously variable HIGH VOLTAGE from zero to maximum rated output voltage. Wide range of up to 100 kV is available in user selectable combinations.
-
product
DC Power Supply
PW-3063R
*Use Toroidal Transformer. Low EMI & High EMS.*Triple output, 0-32V/0-6A X2 and 5V/3A .Max. 400Watts*Tracking operation. Max. output 64V/6A on tracking series or 32V/12A on tracking parallel.*4 display, Green LED shows Voltage and Red LRD shows Current. Easy to read.*Compact design. G.W. 9Kgs only. Easy to handle.*The resolution of PW-3063R as high as 0.1v and 0.01A.*Very low Ripple & Noise, less than 0.4mVrms. Very suit for precise measurement.
-
product
AC Test Transformer
Shanghai Guantu Technology Co., Ltd.
How the AC test transformer prevents the overvoltage generated by the frequency conversion series resonance test device is a relatively simple problem, but the overvoltage caused by voltage fluctuation is difficult to appear when the overvoltage protection is set. Generally, the overvoltage of the frequency conversion series resonance test device will appear in the frequency sweep stage of the instrument, that is, in the process of finding the resonance point. Those who have used it know that in the process of finding the resonance point of the frequency conversion series resonance test device, the voltage and frequency have a parabola-like linear relationship. By default, the system finds the high voltage, that is, the apex of the parabola as the resonance point.
-
product
AC High Voltage Break Down Tester
High Voltage Breakdown Testers also known as Hipot Testers or Insulation Testers are a necessity for any Transformer testing, Substation equipment testing, Cable testing, Panel testing and testing of various insulating materials. Insulation testing is very important to ensure and maintain the safety of electrical equipments and also for the safety of operator.
-
product
MCB Magnetic (Instantaneous) Trip Test Bench
The test bench is specially built for low voltage- B, C & D curve MCBs. Specially designed custom built jigs are able to accommodate single, double, three and four pole MCBs. Decades of experience has helped us to design current source (transformer) in a special way such that good current regulation and high accuracy is ensured with a variable range without the use of any variable transformer in the system. The product is better than the competition with conventional technology at a lesser price!
-
product
Test Sets For Diagnostic Testing
Test Sets For Diagnostic Testing are designed to test Oil Resistivity, Tan Delta, High Voltage Surge Comparison, etc. These test sets are automated instruments used to measure electrical features to insulate transformer oil, liquids and varied other insulating materials. They are ideal for revealing different localized problems and varied weak spots in the insulation. These modern testing sets are designed to provide high accuracy in results. In addition to this, they are easy to maintain testing sets available to ensure accurate readings.
-
product
Transformer Tester
Kvtester Electronics Technology Co.,Ltd
High precision instrument for measuring characteristic parameters of transformer capacity, no-load and load. The instrument is a multi-function measuring instrument, which is equivalent to the usual two kinds of test instruments: the transformer capacity tester + transformer characteristic parameter tester. The utility model can precisely measure a series of power frequency parameters of a plurality of transformers, such as the capacity, the type, the no-load current, the no-load loss, the short circuit (load) loss and the impedance voltage.
-
product
HIGH VOLTAGE SCR CONTROLLED POWER SUPPLY
xPS Series
High Voltage SCR Controlled Power Supply, P/N 18278PS Power Rating: 350 KW. Input: 480 VAC, 3 PH, 60 Hz Output: 0 to 5000 VDC, 70 Amps max Ripple: 2 % approximately at maximum rated voltage Configuration: 12 pulse externally SCR controlled rectifier system Protection Devices: Input contactors Overload relay shutoff Input surge suppressor Thermal switches Output current limiting resistor (made with 5 Ohm Kanthal heating element) Emergency power shutoff Cooling: Each 6 pulse rectifier assembly is cooled by three 10” fans Interface: 4/20 ma converter interface for output voltage and output current to SCR controller. Enclosure: The overall dimension of the unit is (78”H x 38”W x 53”D). It is comprised of two separate enclosures each with dimensions of (78” H x 38” W x 26” D) which are integrated together to form a single enclosure. Each half enclosure has one 6 pulse transformer and one 6 pulse high voltage rectifier. Weight: Approx. 5000 lbs. SCR Controller: The 12 pulse SCR controller is supplied by the customer. We were responsible for the 12 pulses Transformer and 12 pulses Rectifier section. Portability: Unit can be lifted up with a fork lift. It can also be moved around with a 5000 lb pallet jack. Transformer: Two 200 KVA transformers are used to step 480 VAC to 3750 VAC each in a 12 pulse configuration Rectifiers: Two 6 pulse rectifier assemblies capable for 5000 VDC and 60 Amps output were used. The high voltage rectifier assemblies are isolated and protected in a fiberglass plenum within the enclosure. Blocking Diode: Each diode of the 6 pulse rectifier consists of 10 diodes in series to offer a blocking voltage of 12000 V (PIV)
-
product
Tap Adapter
Techimp Voltage Tap Adapter is gender changer which allows the user to connect to the test tap (sometimes called power factor tap) of high voltage transformer bushings.While keeping the test tap well below the safety voltage level required by the manufacturer, the Tap Adapter lets the user to drain high frequency PD signals for diagnostic assessment of insulating materials.A synchronization signal can be derived as well.It is suitable for both single shot as well as continuous PD monitoring.Although it must be customized on the basis of the shape and dimension of the test tap (to be provided by the Customer), many models are readily available for the most established transformer bushings. A list of the presently available models is reported below.Several thousands of hours of operation are a guarantee of reliability and accurate design.
-
product
Isolated LVDS
Isolated LVDS (low voltage differential signaling) devices couple differential signals applied to the LVDS receiver inputs across the isolation barrier to the outputs on the other side and re-transmits the bit stream or clock as LVDS. Analog Devices' drop-in LVDS isolators offer designers robust, high speed differential signaling for point-to-point and multidrop applications. Extending iCoupler® chip scale transformer technology for ultrahigh speed data encoding, these LVDS isolators support a a data rate of up to 2.5 Gigabits per channel for a total bandwidth of 10 Gbps. In contrast to expensive fiber implementations, deserialized links over standard digital isolators or optocouplers, and design-intensive bespoke solutions using transformers or high voltage capacitors, ADI Gigabit Digital LVDS isolators offer the only integrated comprehensive, high performance isolation at 10 Gbps. High performance galvanic isolation for applications include analog front-end (AFE), processor to processor serial communication, or video and imaging data (such as HDMI isolators) as well as isolation between boards, or at a cable interface for LVDS or CML signal chains.
-
product
Transformer Ratio Meter
TRM 1000
AJIT Transformer Ratio Meters are the most modern turn's radio meters widely used to test the turn's ratio of high voltage windings, to low voltage windings, of Transformer. These meters are accurate, compact & light in weight.
-
product
Potential Transformer Test Set
Supreme Instrument Laboratories
The two voltage vectors, one from Standard Potential Transformer and the other from the Potential Transformer under test energies the high permeability magnetic core and then associated windings try to annual the residual magnetism which occurs due to error. The differential vectors will be proportional to phase error and ratio error magnitudes.
-
product
Cylinder Type Transformer Systems
YDTW\YDTCW Series
Shanghai Jiuzhi Electric Co., Ltd.
Conventional AC test transformers are especially designed for testing objects of medium capacitance. These systems are particularly suited for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (inductive voltage transformers).The possibility of stacking several of these transformer modules allows reaching very high voltage levels by keeping reasonable floor space.
-
product
Embedded Synchro - Resolver -
LVDT I/O Cards
Computer Conversions Corporation
100% Transformer Isolation is offered for all AC I/O, and various Isolated DC converters are available as standard product, eliminating concerns for ground-loops, ground interjected (intermittent and ghostly) field noise, inductive surges, differing potentials, and high voltage field transients from effecting the card itself, the sensitive ISA bus backplane and any other device or system sharing these signals.
-
product
Transformer Turns Ratio Meter
TTRM 302
SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.
-
product
DIGITAL TURNS TESTER AND DIGITAL LCRTZ METER
TURNS-LCRTZ
Digital TURNS TESTER with LCR for Counting / Measuring Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity , DC Resistance , Inductance (L), Capacitance (C), DC Resistance, Rac, Q, D, ESR and Tan.Toroidal Turns Platforms :TTPT100 : 5 T - 1000 T , TTPT1000 : 500T-10000 T The Platform has 2 connections for the coil and 2 for the probe wire. Measurement principle is based on dynamic comparison of the voltage across one turn and the coil. You will be able to get the polarity or winding indication with respect to the one turn reference.Accuracy : + 0.2% + 0.5T for high and medium permeability cores at suitable test frequency. Internal Diameter must be able to pass a wire as thin as 0.2 mm. External Diameter as high as 200 mm.Test Frequency Selectable in Step : 50 Hz, 100 Hz , 500 Hz, 1 KHz, 5 KHz, 10 KHz. Test Voltage adjustable : 100mV to 1V in steps of 50mV.
-
product
Phasing Sticks
High voltage phasing rods enable phase comparisons to be made at the point of paralleling two circuits without the interposition of voltage transformers or secondary wiring circuits.
-
product
Transformer Turns Ratio Meter
TTRM 101
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 101 measures only turns ratio where as TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
product
AC Voltage Test Systems
HIGHVOLT Prüftechnik Dresden GmbH
AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.