Filter Results By:
Products
Applications
Manufacturers
-
product
MPS™ Methane Gas Sensor
NevadaNano’s MPS™ Methane Gas Sensor quickly and accurately conducts methane gas leak detection in the most challenging environments – from Arctic wellheads to shale fields in South Texas. Immediate alerts and prioritization are made possible because real-time sensor arrays powered by the MPS Methane Gas Sensor continuously feed cloud-based monitors. 24/7 point detection is the ideal solution to achieve fast mitigation of fugitive methane emissions across the entire oil and gas supply chain.
-
product
Chemical Analysis and Corrosion Testing
Performing chemical analysis of metal alloys including both ferrous and non-ferrous alloys.Chemical analysis involves determining the chemical constituents of metals and related materials.An industry leader and co-operating laboratory for qualifying Calibration Standards for Chemical Analysis.Our chemical laboratory processes include Spectroscopy – Optical Emission Inductively Coupled Plasma, gas analysers, wet chemical, Intercrystalline/ Intergranular Corrosion (including G28, G48 etc).
-
product
Multi-gas Monitoring Solution
GASERA ONE PULSE
GASERA ONE PULSE is a versatile and easy to use multi-gas monitoring solution. It offers accurate ppb detection at an unbeatable price. It can be configured for a range of uses and is currently in use by our customers in; detecting SF6 leakage, refrigerant leakage, anesthetic gas monitoring, emissions monitoring of greenhouse gases, soil analysis, occupational health and safety, photocatalysis, animal husbandry, and fume hood performance testing.
-
product
FTIR Motor Exhaust Gas Analyzer
MEXA-ONE-FT
The MEXA-ONE-FT Series simultaneously measures concentrations of multiple components, including NH3, N2O, CH4, CO and CO2, in undiluted exhaust gas using the Fourier transform infrared (FTIR) method in combination with a multivariate analysis algorithm. It incorporates HORIBA's proprietary compact interferometer which yields superior performance and high accuracy.The system complies with NH3 testing requirements of Euro VI, the EU regulation for heavy duty emissions testing.The MEXA-ONE-FT can be calibrated according to customer requirements with up to 6 component sets to cover a wide range of applications.FTIR spectroscopy allows the direct measurement of NO2 emissions and the independent quantification of individual hydrocarbon species. This makes the MEXA-ONE-FT system an ideal solution for detailed research and development tasks.Due to the measurement principle, the time-consuming daily span gas calibration is omitted.In addition, usability and flexibility are realized by “HORIBA ONE PLATFORM” which enables to extend the system with other ONE analyzers to a complete solution suitable for both certification and R&D purposes.
-
product
Gas Well Casing Seal
WellBore Seal
LANDTEC Wellbore Seal prevents gas leaks and air intrusion with an impermeable membrane that clamps onto a well casing and extends beyond the well bore. The impermeable barrier also allows landfill operators to us higher vacuum pressures at the wellhead with less concern about air intrusion and possible subsurface fires. Higher vacuums can help minimize emissions and subsurface migration.
-
product
Combustion Gas Analyzers
Zirconia
ABB combustion gas analyzers are designed for combustion optimization / control and emissions monitoring applications. The range includes in situ Oxygen only analyzers and an Oxygen plus combustibles (carbon monoxide equivalent COe) close-coupled extractive analyzer.
-
product
Acceleration Simulation Mode (ASM) for Single Driven Axle Vehicles
ASM_AF | VP 230045
Maschinenbau Haldenwang GmbH & Co. KG.
The ASM-AF roller set is used in test centres and is suitable for vehicles with a single driven axle. It was designed for the exact measurement of the exhaust gas behaviour of vehicles during their transient emission test and permits a driving resistance simulation for the exhaust gas tests ASM-5015 and ASM-2525 (Acceleration Simulation Mode) in accordance with the specifications BAR '97. The ASM-AF is built into the base.
-
product
On-board Emissions Measurement System for SPN10
OBS-ONE SPN10 Unit
The OBS-ONE SPN10 unit is an on-board emissions measurement system for analyzing the SPN10 (solid particle number emissions >10 nm) under real-world driving conditions. It meets the latest trends in particle number regulations in the future.The SPN10 unit combines with the GAS unit and the NH3/N2O unit to measure the specified exhaust gas components, along with the exhaust gas flow rate, the GPS position, and the atmospheric conditions (temperature, humidity, pressure).
-
product
Chassis Dynanometer for Motorcycle
•Adopted FAMS-R5 system for motorcycle chassis dynamometer•Gas emission test, durability test, performance test, and environmental test are applicable to various vehicles (motorcycle, tricycle,ATV).•Newly designed measurement unit in a test room makes measurement easier.•Reduction of initial cost, space saving, and less maintenance items by lineup of electric inertia type chassis dynamometer that can be used for small to large vehicles.•Components necessary for emission test are included, such as front wheel holding unit, engine cooling fan, drivers display.•Application software necessary for emission test is installed, such as road resistance setting software, drivers aid,gas emission data processing software, rear axle output data processing software.
-
product
Continuous Gas Analyzer
CT5400
Multi-component continuous gas analyzer combines QCL and TDL technologies in a single rack mount enclosure to measure process gas and monitor emissions from sub ppm to % levels. The CT5400 is ideal for measuring NOx, SO2, CO, CO2, CH 4, NH3, O2, HCl and other combustion gases identified as pollutants, ozone depleting, or responsible for global warming.
-
product
Continuous Emissions Monitoring
atmosFIR CEM
atmosFIR CEM is a complete emissions monitoring system incorporating the atmosFIR 19” FTIR analyser. As completely hot and wet emissions measurement, atmosFIR CEM is ideal for complete measurement of multiple gases from applications such as incineration and power. A standard gas suite of NO, NO2, N2O, SO2, NH3, HCl, CH4, O2, CO2 and H2O is provided, but with the powerful FTIR analyser, further gases can be added easily in software.
-
product
Constant Volume Sampler
CVS-ONE
The CVS-ONE series is designed for the measurement of diluted emissions from vehicles and engines. The new integrated operating platform, HORIBA ONE PLATFORM is adopted for the CVS-ONE. The hardware has been significantly downsized from previous designs, reducing test cell footprint requirements. It introduces new functions and is more user-friendly, while still maintaining high accuracy. In conjunction with the MEXA-ONE (Motor Exhaust Gas Analyzer), the system can be used to measure extremely low emission levels such as SULEV. The new CVS reliably supports emission testing requirements of today and into the future.
-
product
4WD Roller Set
ASM-BF/2 | VP 230044
Maschinenbau Haldenwang GmbH & Co. KG.
The ASM-BF/2 4WD roller set is used in test centres and is suitable for vehicles with a single driven axle. It was designed for the exact measurement of the exhaust gas behaviour of vehicles during their transient emission test and permits a driving resistance simulation for the exhaust gas tests ASM-5015 and ASM-2525 (Acceleration Simulation Mode) in accordance with the specifications BAR '97. The ASM-BF/2 4WD is built into the base.
-
product
Acceleration Simulation Mode Roller Set for Vehicles with a Single Driven Axle
ASM-BF/1 | VP 230043
Maschinenbau Haldenwang GmbH & Co. KG.
The ASM-BF/1 roller set is used in test centres and is suitable for vehicles with a single driven axle. It was designed for the exact measurement of the exhaust gas behaviour of vehicles during their transient emission test and permits a driving resistance simulation for the exhaust gas tests ASM-5015 and ASM-2525 (Acceleration Simulation Mode) in accordance with the specifications BAR '97.
-
product
Stack Gas Analysis System
ENDA-5000 series
Continuous simultaneous and high-precision measurement of NOx, SO2, CO, CO2 and O2.HORIBA has over 100,000 CEM systems installed and 30 years of quality and experience. That is the base on which HORIBA's new ENDA-5000 series of stack-gas analysis systems are built. These systems have a small footprint and use cross-flow modulated non-dispersive infrared (NDIR) and magneto-pneumatic detectors that are inherently drift-free. The ENDA-5000 series are superior continuous analysis systems that perform reliably for difficult exhaust gas measurements, when measurement errors cannot be tolerated. This CEM series features a new intuitive touch panel that makes every operation available with the touch of a single button. The ENDA-5000 series systems are also designed for ease of maintenance. They are ideal for a variety of uses, including emissions monitoring from steam boilers, refuse incinerators, and electric power generation plants to assure pollution standards are being met.
-
product
Infrared Camera for Methane and VOC Detection
FLIR GF320
The FLIR GF320 detects hydrocarbon and volatile organic compound (VOC) emissions from natural gas production and use. With this optical gas imaging camera, inspectors can check thousands of components and see potential gas leaks in real-time. The GF320 is lightweight, offers both a viewfinder and LCD monitor, and has direct access to controls. Embedded GPS data helps in identifying the precise location of faults and leaks, for faster repairs.
-
product
On-board Emissions Measurement System
OBS-ONE PN Unit
The OBS-ONE PN unit is an on-board emissions measurement system for analyzing the solid particle number concentration within the specified particle size range under real-world driving conditions. The unit uses a condensation particle counter which is recommended principle by the Particle Measurement Programme (PMP), one of working groups affiliated with UNECE.The PN unit combines with the GAS unit to measure the specified exhaust gas components, along with the exhaust gas flow rate, the GPS position, and the atmospheric conditions (temperature, humidity, pressure).
-
product
Desktop Spectrometer
Electro-Technic Products, Inc.
The RSpec Explorer is an educational tool which makes it possible for an entire class or lecture hall to study atomic emission spectra. This is a great device for hands-on student learning including having students identify the gas in an unknown spectrum tube. Your students will find the software (included) is easy to use right out of the box. Until now, it’s been nearly impossible to teach about light and color using traditional tools like diffraction gratings because you can’t determine if all your students are even seeing the same results of their experiments. But with the RSpec-Explorer’s camera and software system, you will be confident knowing that every student is seeing the same thing.
-
product
Radiation Detectors
A radiation detector is a device for measuring nuclear, electromagnetic or light radiation. A nuclear radiation detector identifies nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a geiger counter, a nuclear radiation detector consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or nuclear radiation detector.
-
product
Portable Gas Analyzers
IMR Environmental Equipment, Inc.
Flue Gas Analyzers for residential and commercial applications (HVAC, heating contractors). We also offer hand held Combustion Gas Analyzers and professional Flue Gas Analysis instruments in rugged boxes that can measure combustion efficiency and the emissions of furnaces, boilers etc.
-
product
Mobile Gas Flare
Small-sized and quickly ready-for-use gas flare for safe flaring applications of natural gas,hydrogen or other combustible gases.For reduction of operational methane emissions during commissioning and decommissioningof gas service lines in the house connection area (according German DVGW worksheet G 404).Suitbale for emptying of gas tank facilities.
-
product
Deep Ultraviolet Spectrophotometer System
VUVAS-10X
A new ultraviolet spectrophotometer system for optical metrology just arrived at NASA Goddard! The VUVAS-10X spectrophotometer works best in the 90 to 160 nanometer wavelength range, also known as deep or vacuum ultraviolet (VUV) region. It uses a windowless hydrogen plasma light source and differential pump section to reach many wavelengths beyond those of conventional deuterium lamps. The source also works with other gases, or gas mixtures, for atomic spectral line emission from about 30 nanometers (double ionized Helium gas) up to the Visible light range. The new spectrophotometer system, McPherson VUVAS-10X, uses a one-meter focal length high-resolution monochromator with the special light source, scintillated detector and Model 121 goniometric sample chamber. The system is ideal for optical transmission, absorbance and specular reflectance at incident angles up to 60 degrees. This McPherson spectrophotometer system will help develop, inspect and qualify optical materials and coatings used for very high altitude and extraterrestrial space flight missions.
-
product
Geiger Counters
A geiger counter detects nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a radiation detector, a geiger counter consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or radiation detector.It is very important to measure radioactivity as well as to classify radioactivity values. For example, terrestrial gamma radiation is measured according to general values from 0.03 - 0.3 µSv/h (microsievert / hour). This "normal" oscillation range is conditioned by natural radioactive elements in the ground such as uranium and potassium. To calculate this factor, one must take into consideration cosmic radiation. For example, when considering cosmic radiation, the maximum radioactivity content at Schneefernerhaus, the highest-located German environmental research station, is approximately equal to 110 µSv/h.At PCE Instruments, you will find three types of geiger counter or raditation detection devices to help you measure radioactivity: 1) alpha radioactivity meters, 2) meters for detecting alpha, beta and gamma radioactivity and 3) radioactivity meters for human beings.
-
product
Power Meter
PM-10,PM-15
Standard Electric Works Co., Ltd
● Determine the running cost your appliances.● Make informed decisions when purchasing appliances and equipment.● Reduce your electricity bill.● Measure Voltage, Current, Power, Volts, Amps, Power Factor, and Greenhouse Gas Emissions.● Calculate electrical expenses by day, week, month, and even an entire year.
-
product
SF6 Optical Gas Imaging Camera
FLIR GF306
The FLIR GF306 optical gas imaging camera visualizes sulfur hexafluoride (SF6) and other gas emissions without the need to shut down operations. SF6 is used in the electric power industry as an insulator and quenching medium for gas-insulated substations and circuit breakers. The portable, non-contact GF306 allows you to quickly scan substations for leaks while maintaining a safe distance from high-voltage equipment. By catching leaks early, the GF306 reduces lost revenue to breakdowns and repairs.
-
product
Emission Monitoring Systems
Gasmet’s emission monitoring systems set the standard for accurate, reliable, and cost-effective gas analysis. Our state-of-the-art solutions are designed to provide precise measurements of gaseous emissions, making compliance with environmental regulations seamless. With a focus on continuous emission monitoring systems (CEMS), we deliver innovative technology that balances sensitivity, durability, and affordability. Our products are fully TÜV and MCERTS-certified, ensuring world-class quality and performance. Trusted globally, our emission monitoring solutions are the future of gas analysis, empowering industries to meet stricter environmental requirements effortlessly.
-
product
OEM Gas Analyzers
Reduce gas measurement costs with modules that measure multiple gases and eliminate field calibration. Our Andros OEM gas modules lead the way in non-dispersive infrared (NDIR) gas analysis for automotive emissions and patient monitoring.
-
product
Gas Moisture & Sulfur Analyzers
Get fast responses and wide measurement ranges for reliable emissions monitoring. Our gas moisture and sulfur analyzers provide a solution for continuous and accurate determination of total sulfur in flare gas (high and low ranges), allowing sulfur emissions in process heaters and flares to be successfully monitored by petroleum refineries requiring compliance.
-
product
Field-Deployable Analyzer
Verax CTX/CTXe
Produces stream composition (C1-C9+) and BTU (natural gas) or API gravity (liquids and crude) and more10 second measurement cycle timeEnables real-time monitoring and controlNatural gas, NGL, condensate, crude oil and refined fuels capabilityNo sampling system, zero emissions, zero lost productRequires no analyzer shelter
-
product
Quantitative Optical Gas Imaging System for GF620/GFx320/GF320
FLIR QL320
The QL320 is a quantitative optical gas imaging (QOGI) system that allows surveyors to measure the leak rates for methane and other hydrocarbons. This eliminates the need for secondary sampling with a toxic vapor analyzer or similar tool. In addition, the QL320 does not require close contact with the gas in order to measure emission rates, making it a safer solution for quantifying difficult-to-measure gas leaks.