Filter Results By:
Products
Applications
Manufacturers
-
product
Test Contactor
RF Scrub
RF Scrub™ Test Contactor’s innovative design combines an extremely short signal path (0.90mm test height) with high wear resistance pins that can operate in a wide temperature range.The RF Scrub Test Contactor’s long-life, elastomer free design and easy field maintainability makes it an optimal solution for testing of high-performance devices.The RF Scrub design minimizes load board wear and with the unique pin base material and plating, the cleaning intervals can last up to 100,000 cycles.
-
product
Safety Products
This ACE product group provides Emergency braking to safely slow down moving loads and reduce damaging forces. Although the safety shock absorbers, TUBUS elastomer bumpers and clamping elements differ so much in design, every single ACE component provides the best protection for your machine.
-
product
GHz Elastomer Sockets
Ironwood’s GHz BGA & QFN/MLF sockets are ideal for prototyping and testing almost any BGA or QFN device application. These ZIF sockets provide excellent signal integrity yet remain cost effective. Innovative elastomer interconnect technology that delivers low signal loss up to >40GHz and supports BGA or QFN/MLF pitches down to 0.3mm was utilized in these sockets. GHz BGA sockets are mechanically mounted over a target system’s BGA lands using mounting and alignment holes at proper locations (page 2 of the individual socket drawing shows recommended PCB layout information). These low-profile sockets are only 2.5 mm per side larger than actual IC packages (industry’s smallest footprint). They support IC devices with body sizes ranging from 55mm down to 1mm. Larger body sizes may require a backing plate. If the backside of the target PCB contains capacitors and resistors, a custom insulation plate with cavities cut for those components can be designed. This insulation plate sandwiches between the backing plate and target PCB.
-
product
Mass Flow Controllers
Enabling Productivity Through Flow Control Innovation. Our wide range of mass flow controllers are available in thermal and pressure based sensor technologies, analog and digital communication, and metal or elastomer seals.
-
product
BGA Sockets
Ironwood has the most comprehensive collection of BGA (Ball Grid Array) sockets that can be used for prototype application, silicon validation, system development, thermal characterization, burn-in application, functional production test, etc. BGA socket can be defined as an electromechanical device, which provides removable interface between IC package and system circuit board with minimal effect on signal integrity. BGA sockets for prototype applications, silicon validations, system development applications uses low cost elastomer contact technology.
-
product
Mass Flow Controller for Low Flow
HFM-200 / HFC-202
The HFM-200/HFC-202 is Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers. Featuring reliability and stability, the 200 Series is chosen by OEM's for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.
-
product
Durometer Hardness Testing
Materials Evaluation and Engineering
Durometer testing is used to determine the hardness of thermoplastic elastomers, vulcanized rubber, elastomeric materials, cellular materials, gel-like materials, and other plastics that are unsuitable for measurement by conventional Rockwell or microindentation hardness testing.
-
product
Digital Durometer
TIME®5410
Beijing TIME High Technology Ltd.
TIME5410 is a digital durometer for measuring the hardness of hard rubber, plastic or elastomers.
-
product
Open Top BGA Sockets
Ironwood has the most comprehensive collection of open top BGA and QFN sockets that can be used for qualification application, silicon FIB testing, system development, thermal characterization, burn-in application, etc. IC socket can be defined as an electromechanical device, which provides removable interface between IC package and system circuit board with minimal effect on signal integrity. Typical packages include BGA, LGA, QFN, QFP, WLCSP, etc. Open top allows access to the top side of IC. Below is an example BGA socket that uses low cost elastomer contact technology.
-
product
Digital "A" Flow Controller for High Flow
HFM-D-306A / HFC-D-308A
Mass flow techniques provide RELIABLE, REPEATABLE AND ACCURATE gas flow rate measurements.HFM-D-306A/HFC-D-308A mass flow instruments have flow ranges from 0-2500 slm to 0-10000 slm; provide analog and digital outputs, and are constructed of stainless steel. Easy, user friendly digital communications with windows based software interface available. Available with a variety of elastomer seals for maximum flexibility.Self diagnostics of the sensor, valve and overflow are included in the digital features. Also of interest is the auto zero feature which detects when the valve is closed and automatically resets the zero. These mass flow meters and controllers can store up to 10 calibrations of different ranges and gases. Another feature is the built in totalizer for monitoring gas usage under user set conditions.
-
product
Silver Ball Matrix Sockets
SM Contact is a unique contact that has precise silver balls held together by a proprietary conductive formulation. These conductive columns (diameter optimized for 50 ohm impedance) are suspended in a non-conductive flexible elastomer substrate with a patented solid core for enhanced durability and reliable performance over time, temperature and cycles. This flexible substrate is very compliant and resilient and enables the conductive columns to revert back to original shape when the force is removed. Solutions are available for 0.25mm to 1.27mm LGA, BGA, QFN, CSP, POP, WLP and other packages. The silver ball matrix contact technology is also available with a protective plunger matrix (a gold plated copper cylinder) that sits on top of the conductive columns. This plunger matrix protects the conductive column from contamination from various solder ball interfaces. A quickly replaceable plunger matrix enables minimal downtime during final production test. The product family code for this line of sockets is SMP.
-
product
Mass Flow Controller for Low Flow
HFM-200 / HFC-202
The HFM-200/HFC-202 is Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers. Featuring reliability and stability, the 200 Series is chosen by OEM's for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-200 / HFC-202 meters and controllers have flow ranges from 0-10 sccm to flows of 0-25 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Many corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available.
-
product
High Performance UV Nanoimprint Resist
AMONIL®
UV Nanoimprint is a mechanical molding technique. A template made from quartz or a flexible elastomer with a 3D relief is brought into intimate contact with a UV-curable resist spin-coated on top of a substrate. Applying low imprint pressure at room temperature features are filled within seconds due to the low viscosity of the imprint resist. The resist is hardened via UV-light through the backside of the template. Finally substrate and template are separated. The replicated resist relief can further be transferred into the substrate via RIE-process or used as functional element.
-
product
Din Abrasion Resistance Tester
SG-P01D
This tester is used to determine the abrasion characters of elastomers, rubber, soft synthetics, leather. etc or is with characters of high efficiency, good reproducibility and easy operation.
-
product
Harness Design and Manufacture
When designing an underwater cable harness, there are some factors which need to be considered, and we have produced the following list as a guide for customer information:Component considerations:- Electrical requirements- Mechanical considerations- Quality requirements- Reliability- Design redundancy (contact count)- Connector selection (type and form)- Locking requirements- Backpotting requirements- Waterblocking in moldings- Cable specification- Cable jacket material and compatibility with elastomers- Abrasion resistance- Stiffness profile at termination- Connector format (straight or right angle)- Molding format (straight or at an angle)- Clearance allowance for molding and cable routing- Elastomer compatibility (eg oil filled units)- Metalwork selection re: corrosion and cathodic delamination- Surface finish for metalwork as appropriateOperational considerations:- Operating depth profile (not just max. depth)- Tensile loads- Torsional loads- Bending loads- Bend control requirements (to limit bending at termination)- Deployment and recovery loads- Dynamic loading-Flow turbulence effects.
-
product
MACRO IRHD System
Hildebrand Prüf- und Meßtechnik GmbH
Durometer Hardness System provides hardness readings on elastomers and plastics with a specimen thicker than 6 mm according to IRHD and Durometer hardness. It complies to international standards DIN ISO 48, ISO 48, ASTM D 1415 and DIN 53505.
-
product
Shore Hardness Tester
HT-6510
Application: shore A is designed to measure the penetration hardness of rubber, elastomers and other rubber like substances such as neoprene, silicone, and vinyl. It can also be used for soft plastics, felt, leather and similar materials. Shore D is designed for plastics, Formica, Epoxies and Plexiglass. Application: shore C is designed for various foam and sponge.
-
product
Digital "A" Flow Controller for Medium Flow
HFM-D-305A / HFC-D-307A
Fast Response, Tight Accuracy!Mass flow techniques provide RELIABLE, REPEATABLE AND ACCURATE gas flow rate measurements.HFM-D-305A/HFC-D-307A mass flow instruments have flow ranges from 0-1000 slm to 0-2500 slm; provide analog and digital outputs, and are constructed of stainless steel. Easy, user friendly digital communications with windows based software interface available. Available with a variety of elastomer seals for maximum flexibility.Self diagnostics of the sensor, valve and overflow are included in the digital features. Also of interest is the auto zero feature which detects when the valve is closed and automatically resets the zero. These mass flow meters and controllers can store up to 10 calibrations of different ranges and gases. Another feature is the built in totalizer for monitoring gas usage under user set conditions.
-
product
Structural Durability Solutions
Instron offers a variety of testing systems and rigs for static, quasi-static and dynamic loading of structures and components. This includes Component Test Systems, Shaking Tables, Road Simulators, Axle Test Systems, Full Vehicle Test Systems, Wheel Test Systems, Shock Absorber Test Systems, Elastomer Test System and Dynamic Torsion Test Systems.
-
product
Fast Response Flow Controller for Medium Flow
HFM-305 / HFC-307
The HFM-305/HFC-307 is Teledyne Hastings' fast response series of mass flow meters and controllers. Featuring reliability and stability, the 300 Series is chosen for its fast response under a wide range of conditions. .The HFM-305 / HFC-307 meters and controllers have flow ranges from 0-1000 slm to flows of 0-2500 slm; provide analog outputs, are constructed of stainless steel and can be configured to have either normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-305 / HFC-307 services a wide variety of applications. Cleaning for oxygen service is available.
-
product
Fast Response Flow Controller for Medium Flow
HFM-301 / HFC-303
The HFM-301 / HFC-303 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-301 / HFC-303 services a wide variety of applications. Cleaning for oxygen service is available.
-
product
Stainless Steel Bell Jar Chambers
MDC stainless steel bell jars are designed for use with MDC baseplates, base wells and feedthrough collars. A dovetail groove in the jar's base flange holds a Viton elastomer gasket, which makes the vacuum seal with one of the forementioned components. All stainless steel bell jars are fitted with a four inch view diameter Pyrex viewport. All vacuum welds are internal and provide UHV compatibility. For added convenience, all bell jars are fitted with a hoist or lift-ring that is welded to the chamber's domed top.
-
product
Fast Response Flow Controller for Medium Flow
HFM-301 / HFC-303
The HFM-301 / HFC-303 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-301 / HFC-303 services a wide variety of applications. Cleaning for oxygen service is available.
-
product
Shore Durometer
UI-FT30
Shore Durometer is used to test hardness of rubber, thermoplastic elastomers, vulcanized rubber and other materials.
-
product
Abrasion Testers
Abrasion tester is used to determines the resistance of elastomers by the frictional loss of the rubber in products, such as tires, conveyor belts, hoses, footwear, floor covering etc.
-
product
Mass Flow Controller for Medium Flow
HFM-205 / HFC-207
The HFM-205/HFC-207, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-205 / HFC-207 meters and controllers have flow ranges from 0-1000 slm to flows of 0-2500 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a full complement of fitting and elastomer options, the HFM-205/ HFC-207 covers a wide range of high flow applications.
-
product
Sockets
Ironwood Electronics Sockets – Embedded gold plated wire elastomer (SG) – Stamped & Etched spring pins (SBT) – Embedded silver ball elastomer matrix (SM/SMP)– Compressible silver button in polyimide (GT/GTP)– Surface mount adapters for sockets (SF)
-
product
Solar Radiation (Sunshine) Test
This test determines the effects of direct solar radiation on components and material. The heating effects of solar radiation differ from those of high air temperature in that the amount of heat absorbed depends on the roughness and color of the surface on which the radiation is incident and the angle of incidence to the sun. Variations in the intensity of solar radiation over the surface of the component, may cause components to expand or contract at different rates, which can lead to severe stresses and loss of structural integrity. In addition, degradation due to photo-chemical changes can occur such as fading of color, deterioration of natural and synthetic elastomers and polymers. The test items that are subjected to solar radiation testing are those that are exposed to solar radiation during its life cycle, in the open, in warm climates.
-
product
Low Pressure Drop Thermal Mass Flow Meter
HFM-200 LFE
The HFM-200 LFE Series by Teledyne Hastings can be configured and accurately measure gas flow in a broad array of applications. Featuring reliability and stability, the 200 Series is chosen by users for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow meter compatible with most gases.The HFM-200 LFE meter has flow ranges from 0-10 sccm to flows of 0-15,000 slm; provides analog outputs, and is constructed of stainless steel. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Cleaning for oxygen service is available. Our laminar flow elements (smooth, threaded or flanged) are available in various sizes from 3/8" up to 8". Low pressure drops at full scale flow.
-
product
Durometers
A durometer gauge or durometer tester is needed to perform a durometer hardness test procedure. Durometer devices determine the surface hardness of many different materials, including polymers and elastomers. Each durometer or hardness tester measures the depth of an indentation in the material caused by a defined force of a given geometric presser foot. The depth of the indentation reflects the hardness of the material. A general distinction is made between static and dynamic methods. In traditional static tests, the test force is applied uniformly with increasing magnitude, while in dynamic testing methods, an instantaneous load is applied.