Filter Results By:
Products
Applications
Manufacturers
Differential Probes
Measure signals that are not ground referenced.
-
product
Differential Probe
With signals becoming faster, and power supply voltages going lower, these active differential probes will allow floating measurements from 100uVolts to as high as 7000 volts. These probes provide high CMRR and a broad frequency range.
-
product
Quad Input Logging Thermometer
DT304
UEi Test & Measurement Instruments
This series of Digital Thermometers offers a unique combination of features including logging capabilities with 9,999 memory positions and a USB interface and software, one, two and four inputs offering relative and differential readings. The Apollo also offers a solution to storing probes and is manufactured to conform to the IP67 standard, meeting performance expectations of water submersion and high-pressure dust resistance
-
product
6 GHz ProBus2 Differential Probe with Adjustable Tip
D600A-AT-PB2
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
Oscilloscope Probes and Accessories
Teledyne LeCroy has a wide variety of world class probes and amplifiers to complement its product line. From the ZS high impedance active probes to the DH Series Differential High-bandwidth Probes which offers bandwidths up to 30 GHz, Teledyne LeCroy probes and probe accessories provide optimum mechanical connections for signal measurement.
-
product
High-Voltage Differential Probe, 200 MHz
N2805A
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
product
500 MHz 60 V Common Mode Differential Probe
DL05-HCM
60 V of common mode and 80 V differential input range with 1 GHz of bandwidth, make these probes ideal for lower voltage GaN power conversion measurements. The 60 V of common mode is well suited for handling any float of the battery and bulk/absorption voltage during charging, while the 80 V differential input range provide margin for any overshoot.
-
product
1kV, 120 MHz High Voltage Differential Probe Without Tip Accessories and with Auto Zero Disconnect
HVD3106A-NOACC
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
4 GHz ProBus2 Differential Probe with Adjustable Tip
D400A-AT-PB2
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
1.5 GHz, 1.0 pF Active Differential probe
ZD1500
With the ProBus interface, the ZD500, 1000, and 1500 becomes an integral part of the oscilloscope. All probe gain and offset controls are transparent to the user, making it easier to probe the circuit without concern for which gain setting to choose. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
product
30 GHz differential probe with ProAxial interface
DH30-PX
30 GHz differential probe with ProAxial interface.
-
product
Differential Probe
DP-40K
*MAX. Input Voltage: ±20KV DC or 40KV p-p or AC 14KV rms*Bandwidth: DC-20MHz*Input Impedance 100MΩ// 1PF*x500, x5000 Attenuator*To Ground MAX. Voltage: 10KV CAT III*Output Impedance 50Ω
-
product
2kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3206A
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
DH Series PT Browser Tip, 16 GHz BW, 3.5 Vpp Range
DH-PT
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
product
18 GHz Differential TDR/TDT Probe Kit
N1021B
Connect PCBs and other devices without connectors to TDR/TDT modules in the oscilloscope mainframe
-
product
HandyScope HS6-DIFF With SafeGround & SureConnect: 500 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-500XMSG-W5
The only oscilloscope in the world that has:- SafeGround, differential input channels that can be switched to single ended.-SureConnect, auto-detects a true connection between the probe tip and the device under test.- CMI interface.- USB 3.0 interface, 5Gb/s data transfer- Lowest noise
-
product
Differential Probe / Paired ProbeTOP
*1 Measured at 23°C environment connected to PS-02/PS-03 power supply(optional)*2 Broadband Noise, Bandwidth 30 MHz*3 Referred of output*4 Must be met to achieve best performance and avoid Damage to the Probe*5 Parts#890-880-104 : Twinholder M6 and 890-880-112 : Pair of Rail Clip Connectors 4mm are optional.
-
product
Residential/Commercial Combustion Analyzer Kit w/ NOx Sensor/Printer
C165+NKIT
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C165+ Residential/Commercial Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and differential pressure. Prints to optional printer and wireless App. The new LINK feature connects the included wireless pipe clamp temperature probes and other optional probes to the C165+. Essential information for installing and maintaining furnaces and boilers all in one device.
-
product
VELOCICALC Multi-Function Ventilation Meter
9565-P
The portable, handheld VELOCICALC® Multi-Function Ventilation Meter 9565-P features a menu-driven user interface for easy operation in your local language. On-screen prompts and step-by-step instructions guide the user through instrument setup, operation, and field calibration. The 9565-P also features an ergonomic, overmolded case design with probe holder and a keypad lockout to prevent tampering during unattended use. The 9565-P model has a differential pressure sensor and does not include a probe.
-
product
13 GHz Differential Probe with ProLink Interface
DH13-PL
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
product
Differential Voltage Probes
DP150/DP200pro
The DP differential isolation probes are an important accessory for any laboratory involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, whilst the oscilloscope can remain grounded. Using a DP150 or DP200pro probe, differential and floating measurements can be made on a variety of ac power systems like 230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope. The DP probes can be powered from a 9V battery or external power supply.
-
product
500 MHz Active Differential Probe
AP033
Fully Integrated: With the ProBus™ interface, the AP033 becomes an integral part of the oscilloscope. The probe sensitivity and offset can be controlled from the oscilloscope front panel, the probe front panel, or by using remote control commands (GPIB or RS-232). Sensitivity, offset, input capacitance, and common mode voltage range are displayed on the oscilloscope screen. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
product
High Frequency Coaxial Analytical Probes
D-COAX offers four analytical probe models: HyPac model for package characterization, and two models, Omni and OmniJet, for board level characterization, and DP1.4mm differential, single-ended probe.
-
product
Current Probe
DCP-BTA
Vernier Software & Technology, LLC
The Current Probe measures DC and low-frequency AC currents up to 600 mA. Use Current Probes in combination with Differential Voltage Probes to investigate Ohm's Law and explore series and parallel circuits. The 0.1 shunt resistor minimizes changes to your circuit. If currents will exceed 1 A, use the High Current Sensor.
-
product
High Voltage Differential Probes
DP Series
Shenzhen Micsig Instruments Co., Ltd.
*Micsig DP Series High Voltage Differential Probes can be used with any brand of oscilloscope. *It adopts high-impedance isolation between the input and output to protect personal safety, converts the input high-voltage signal to a low-voltage signal for observation and analysis on oscilloscope.
-
product
High-Voltage Differential Probe, 70 MHz
N2891A
Use the N2891A 70-MHz high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2891A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to ±7000 V of differential and common mode voltage.
-
product
Differential Probes (8-30 GHz)
The DH series of 8 to 30 GHz active differential probes provides high input dynamic range, large offset capability, low loading and excellent signal fidelity with a range of connection options.
-
product
25 GHz Differential Probe with 2.92mm Interface
DH25-2.92MM
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
product
Handheld Portable Multifunction Data Logger
HD31
Three independent input channels Automatic recognition of the probes - Measurement of Temperature Relative Humidity Atmospheric and differential pressure Air Speed Illuminance (lux) and Irradiance Carbon dioxide (CO2) – Air Quality Direct voltage (VP473 module) and current (IP472 module).
-
product
Digital Oscilloscope
DS6000 Series
The 6000 Series Digital Oscilloscopes have 1 GHz of Bandwidth. Detecting high speed signals and device characteristics including ESD, digital video, and differential signals (using an differential probe accessory) is now easier than ever with our most advanced digital oscilloscope platform.
-
product
Differential Probe
DP-16VF
*MAX. Input Voltage: ±8KV DC or 16KV p-p or AC 5.6KV rms*Bandwidth: DC-150MHz*Input Impedance 20MΩ // 5PF*X400, X4000 Attenuator*To Ground MAX. Voltage: 3.5KV CAT III*Output Impedance 50Ω