Filter Results By:
Products
Applications
Manufacturers
-
product
PXI Analog Output/Current Loop Simulator Module - 12 Channel
41-765-002
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Measurement & Simulation
Highland Technology offers a wide array of tools for measurement, simulation, and control. Tachometers, thermocouples, RTDs, precision voltages, current loops, strain gauges, and more can be measured or simulated by Highland's products.
-
product
Mezzanine System
5658
ECM P/N 5658 provides eight channels of 16 bit current measurement in the 0 to 25 milli-amp range. Each channel allows independent common mode voltages from -100 volts to +100 volts. Current detection is accomplished with a precision 100 ohm current sense resistor, creating a voltage drop of 2V in the current loop at 20 milli-amps.
-
product
Short Circuit Loop Impedance Meter
AMZC-304
Short circuit loop impedance measurement in networks with nominal voltage: 220/380V, 230/400V, 240/415V, with frequency 45…65Hz ; Short circuit loop impedance measurement with 15mA current, without triggering RCD. ; Detection of the replacement L and N in the socket and automatic swap in the meter
-
product
Loop-Powered Transmitters and Drivers
4-20mA
Loop-Powered Transmitters convert the output from proximity probes, seismic sensors, into a 4-20mA DC current, which is proportional to the input being measured. The transmitter converts the displacement or vibration signal to DC voltage and/or current for a DCS or PLC system. They control a 4-20mA current loop for a specified vibration range (ex. 0-5 mils peak-to-peak). The transmitters have a two-wire hook-up, powered solely by the loop current and have a power supply range of 15 to 36 volts.
-
product
Multi Function Testers
Kyoritsu Electrical Instruments Works, Ltd.
Live circuit warning LED:Immediate illumination of a warning lamp if the circuit under test is live Auto Discharge:Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing Integral overload protection on internal continuity and insulation test circuitry Autoranging 500V DC test voltage for insulation tests 200mA short circuit current on continuity ranges Loop and RCD Testing Wiring connection check LED''s:Immediate indication if wiring of circuit under test is correct Overheat Protection:Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement Supply Voltage Indication:Can display supply voltage value in loop impedance mode Low Current Loop Impedance Test:Short duration low test current will prevent tripping of many passive RCDs
-
product
Bench Digital Multimeter, 40000 Count, True RMS, Auto, Manual Range, 1 kV, 10 A, 4.75 Digit
72-1020
This unit measures AC/DC voltage and current, resistance, capacitance, frequency, and temperature. It also provides diode and audible continuity test, as well as 4~20mA loop testing.
-
product
Industrial 4-20mA DAC Solution
Analog Devices portfolio of leading industrial digital-to-analog converters address the challenges of enhancing system accuracy, reliability, and overall functionality while reducing form factor and power dissipation. The products provide a range of programmable output ranges from standard 4–20 mA for current loop communication to ±10 V for actuator control. They simplify industrial system design by offering considerable control functionality and advanced on-chip diagnostics to maximize system up time. ADI industrial converters also eliminate the need for costly calibration routines needed by some traditional discrete architectures.
-
product
AC Current Sensor
RCTi and RCTi 3ph
The RCTi & RCTrms sensors convert ac current to an isolated 0-5V voltage or 4-20mA current loop. TA5V-5A allows compatibility with existing 1A or 5A CT metering circuits. Both offer a choice of proportional (rms) and instantaneous outputs. The available RCT current ranges are 0-100A to 0-50,000Apk. Both RCTi and RCTrms provide accurate measurement over a wide bandwidth ensuring precise measurement even with harmonically distorted wave shapes - using a flexible clip-on sensing coil. The RCTs are available as single and three phase models.
-
product
Three Axis Helmholtz Coil Systems
Macintyre Electronic Design Associa
he MEDA turnkey closed loop magnetic field sources cancel the local ambient field as well as generate accurate and uniform magnetic fields in a control volume. The sources use Helmholtz coils driven by control currents to produce stable magnetic fields from 1 nT to 100,000 nT. The accuracy of the field in the control volume is better than 0.05% of the setting.
-
product
Closed Loop Hall AC/DC Current Sensor
CYHCS-SH
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can beused for measurement of DC and AC current, pulse currents etc. The output of thetransducer reflects the real wave of the current carrying conductor.
-
product
100 Ampere Micro OHM Meters
Introduction: Measuring the line loop contact resistance by bridges is not the ideal method as the test current is only a few milli amperes. Thus the value is not the true value of the contact resistance. Model HL- 100 is a direct reading tester, and uses a test current of 100A DC, resulting in true v alue and accur ate measurements. Model HL- 100 adopts digital circuit technique and is used for measuring contact resistance of switch control equipments at test current of 100A DC. The measurements are accurate as the test is highly stable.HL- 100 is a new, fully automatic micro controlled tester that measures contact resistance at 100A DC with built in printer. The advantages of HL-100
-
product
180V-260V AC Socket Tester With RCD Test (For UK)
1943
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*Test for 180~260VAC circuit.*LED indicators & Digital display.*30mA leakage current measurement.*RCD Test.I*t can perform self test after plug-in ( Voltage sould be above 180V ).*Detect faulty wiring status in 3 wire receptacle.*This socket tester will give LED indication as well if the main voltage is below 200V or above 260V.*Earth loop impedance test.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 11W*Frequency: 50Hz
-
product
4 (High Current) D/A Outputs (±40 VDC or +100 mA)
DA3
The DA3 module features 4 high-current D/A output channels with a full-scale range of ±40 VDC or ±100 mA (max). The DA3 provides either voltage or current control loop modes that are programmable for the particular application.
-
product
Digital LOOP/PSC/LOAD Tester
1825 LP
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures the voltage drop as if 16A was flowing between Line and Neutral.● Displays voltage without current (V at 0A).● Display voltage as if 16A flowing between Line and Neutral (V at 16A).● Loop test for L-E● PSC between L-N.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software range).● Combined prospective short circuit current, loop and load tester.● Display can be customized for large orders.
-
product
Closed Loop Hall Effect Current Sensors/Transducers
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor
-
product
2-Port Serial Interface
APCI-7420-3
*RS232, RS422, RS485, 20 mA Current Loop (active, passive) with or without optical isolation*Modular structure through MX-modules*With or without optical isolation*Mode configuration free for each port*128-byte FIFO-buffer common interrupt*Automatic direction recognition for RS485*Transmission mode: asynchronous, full, half duplex
-
product
48 Ω HMM Pulse Force Probe
PHD-HMM-48-1
High Power Pulse Instruments GmbH
*High current wafer-level and package-level 98 Ω HMM probing with grounded DUT*Built-in high surge 48 Ω pulse reflection suppression resistor up to 80 A peak*Fast rise time < 0.5 ns due to low inductance GND loop*Variable pitch from 50 µm to 5 mm*Tungsten replacement probe tips*SMA pulse force pigtail*Compatible to PHD-3001A interface*High reliability
-
product
Digital Multimeter, USB Interface, 20000 Count, True RMS, Auto Range, 4.5 Digit
72-7730A
Digital multimeter is a 20,000 counts and 4-1/2 digits with steady operation. The meter can measure AC voltage and current, DC voltage and current, resistance, capacitance, temperature frequency, diodes, continuity, 4 to 20mA loop, Max/Min, relative mode but also has data store, data recall, AC true RMS, AC+DC, low battery display, double display backlight, automatic power off and full overload protection.
-
product
Precision Current Loop Calibrator With Hart Communications
LC-110H
The Martel LC-110 and LC-110H are mA (loop) calibrators designed to take the loop calibrator class to the next level. The new LC-110 series feature a user friendly interface with dedicated buttons and a rotary encoder (Quick-Set Knob). This combination drastically reduces the time it takes to measure, simulate, or source both voltage and current and power up a loop. The rugged ABS plastic case is contoured to easily fit a technician's hand and the large back lit graphics LCD is best in class. The LC-110H differs from the standard LC-110 in that it incorporates HART communications and supports a select set of the HART universal and common practice commands. This unique feature allows the LC-110H to be used as both a loop calibrator and communication tool.
-
product
PCI Express 8 Reed Relay Output
8012e
The 8012e Low Profile PCI Express digital interface provides eight optically isolated inputs and eight Reed relay outputs (SPST). The isolated inputs are non-polarized and rated for 3-30 VDC. Optical isolation protects the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments.
-
product
Rechargeable Multifunction Tester
ET4000
The new ET4000 tester carries out all the tests needed to verify the safety of electrical installations in domestic, commercial and industrial wiring installations in accordance with the latest regulations.
Everything about the new ET Series has been designed to save time and make testing easier.
Fast, reliable high current and non-trip loop testing comes as standard together with a high level of input protection and a CAT IV safety rating .
Supplied with a full range of accessories.
-
product
Multifunction Electrical Installations Meter
MPI-520
The MPI-520 multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520 is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.Wide range of standard accessories enable to perform all necessary measurements and safety test. Highly professional portable multifunction meter with memory of measured parameters.
-
product
Remote Indicators
ABB field indicators provide a convenient way to access the field instruments data when they are located in remote or difficult to access areas. Powered directly from the 4-20 mA current loop, they require minimal effort to setup.
-
product
Ground Fault Finder
FST-JD200 DC
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1. The high-precision sampling clamp meter The device uses a high resolution (0.1mA) signal sampling direct current clamp meter that can achieve multi-point grounding and high resistance ground point positioning...
-
product
AC Power Sources, Frequency Converter
MAC-01, -02, -03
For reliability, all models of the Titan AC Power Sources/Frequency Converters are fully current limit protected against either continuous or transient short circuit or overload conditions. When an overcurrent condition exists, the internal current control loop overrides the voltage control loop and scales back the sinewave drive until it sees a safe output current level.
-
product
H/L Voltage Clamp Meters
High Voltage Current Transformation Ratio Tester breaks traditional structure, specially designed for high and low voltage first and secondary loop current, variable ratio, and current leakage test; apply the latest CT technology and mask digital integration technology, composed of special high-voltage clamp, low voltage clamp, host, high voltage insulation rod and monitoring software, etc; its wireless transmission test data can penetrate multiple building obstacles with a straight-line distance of 30 meters.
-
product
PXI Analog Output/Current Loop Simulator Module - 16 Channel
41-765-001
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
NI-9266, 8-Channel C Series Current Output Module
785047-02
8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.
-
product
C Series Current Output Module
The C Series Current Output Module features up to eight channels of simultaneous analog output. You can choose between enclosed and non-enclosed modules. Additionally, the C Series Current Output Module has built-in open-loop detection. This detection generates an interrupt in software when an open loop is detected, zeros outputs to ensure safety, and avoids driving actuators at system power-on. The C Series Current Output Module requires an external power supply and includes a channel-to-earth ground double isolation barrier for safety and noise immunity.The C Series Current Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.