Material Science Laboratory Instruments
our material science laboratory instruments basically consists of four instruments first, young modulus apparatus which is used for determining the young modulus elasticity of a wire by stretching it. Then second is curie temperature kit which is used for determining the Curie Temperature. With the determination of dielectric constant of PZT material with Temperature variation. After that comes dielectric constant kit which is used for measuring the dielectric constant of solids and lastly our universal B-H Curve Tracer which is used for tracing the B-H loop which is very difficult and needs a good machinery for doing so.
-
product
Automatic Hysteresis Graph Test System
DX-4DMT
X-4DMT automatic hysteresigraph system accords with the standard permanent magnet test system, GB3217-92, used to measure the major and minor hysteresis loops, demagnetization curves, recoil hysteresis loops and initial magnetization curves in different temperature of ferrite, AlNiCo, SmCo, NdFeB and quenched material, and gives the magnetic parameter, Br, Hcb, Hcj, (BH)max, Hk and so on, and could meet different requirements on test function, precision, power capability, reliability, efficiency, price, local environment from laboratory to enterprise's production line.
-
product
Magnet Tester
H30 Series
AlmiCo, Ferrite, NdFeB, SmCo5, Sm2Co17 magnets are tested and their B-H and MH loops are plotted using Ferrites India make H30 Series hysteresis loop tracers. The complete system consists of a magnetizer to magnetize the test piece, an electromagnet and a BH Loop Plotter. Magnets with coersivity as high as 13 kOe and more can also be tested.
-
product
Fluxmeter
Measure total flux in industrial and measurement system settings—ideal for magnet testing and sorting and as the main component in BH loop or hysteresisgraph measurement applications.
-
product
Loop Meter
MZC-310S
The MZC-310S is a professional portable meter for testing electrical installations with over-current circuit breakers. The instrument measures short-circuit L-PE, L-N and L-L loop and prospective short-circuit loop current. A measurements can be done either with low testing current (up to 42A) with 2-pole method or high testing current (up to 280A) with 4-pole method that enables measurements with very high accuracy and resolution.
-
product
B-H Analyzers
Precise and accurate core loss measurementIwatsu's B-H analyzers which hiring CROSS-POWER method (IEC62044-3)enable precise and highly accurate measurement embedded minimized phase error integration on frequency spectrum with current detecting resisters and compensation on detecting circuit with full compensation on amplitude and phase characteristics.
-
product
Loop Antennas
A loop antenna is a radio antenna consisting of a loop or coil of wire, tubing, or other electrical conductor, that for transmitting is usually fed by a balanced power source or for receiving feeds a balanced load.
-
product
Antenna, Loop
EM-6871 | 30 Hz – 1 MHz
The EM-6871 Antenna can be used with any 50 ohm /Receiver/Field Strength Meter to obtain magnetic field measurements from 30 Hz to 1 MHz.
-
product
Antenna, Active Loop
EM-6869 | 9 KHz – 50 MHz
The Electro-Metrics EM-6869 Active Loop Antenna is used with any receiver or spectrum analyzer with 50 ohm input and covers the frequency range of 9 kHz to 50 MHz.
-
product
B-H Analyzer
SY-8218 / SY-8219
Soft magnetic components made of ferrite play an important role in electric components as they are used in a broad range of applications from low-frequency applications such as yokes for micromotors, to high-frequency applications such as flyback transformers, deflecting yokes, high-frequency transformers and magnetic heads. In actual operation, these magnetic components display characteristics different from DC magnetic characteristics or characteristics measured with an LCR meter.
-
product
Test Loop Translators
Incorporating fundamental frequency phase locked oscillators and double balanced mixers, the translators block convert frequencies from uplink to either downlink or L-Band and from L-Band to downlink for instantaneous monitoring of frequency, power levels and modulation.
-
product
Monitoring Loops
The Loop Sensor was designed to monitor the generated magnetic fields in radiated susceptibility tests.
-
product
Recorder for non-stop(Loop)
You just set the desired number of the days to keep track of, and Stream MultiRec will record them uninterruptedly 24 hours a day with no human intervention. The number of tracked channels is defined by the user depending on specific requirements and the storage capacity of the video server in use.
-
product
Open Loop Current Sensor
C03 30A
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
product
Single Loop Controller
1160+
The 1160+ controller is an evolved product from the West N6100. The product benefits from having more versatile features and user-friendly functionalities such as remote setpoint inputs, digital inputs, plug-in output modules, a customisable operator/HMI menu, jumperless and auto-hardware configuration, and 24VDC transmitter power supply.
-
product
Current Loop Adapter
OP-1C
This adapter supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
product
Active Loop Antenna
AL-130R
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.
-
product
MULTI-STANDARD LOCAL LOOP SIMULATOR
458-LM-A8-30
Accurately simulates attenuation and impedanceFull bidirectional operation at all specified frequencies26 AWG PIC as specified in ANSI T1.417
-
product
Antenna, Loop Sensor
EM-6873 | 20 Hz – 100 KHz
The EM-6873 Loop Sensor Antenna uses passive circuits to transform magnetic field components between 20 Hz – 100 kHz to an equivalent open circuit two-terminal voltage on the receiving instrument. Use of the conversion Factor Chart, supplied with each antenna, will yield the strength of the magnetic induction field referenced to a uniform field. The loop is electrostatically shielded and therefore is sensitive only to the magnetic component (B-field) of the electromagnetic fields.
-
product
Modular Breakout System for Hardware-In-Loop Simulation
Designed in partnership with OPAL-RT Technologies, this Modular Breakout System combines a BoB feature set with the added flexibility of an FIU. By mating the FIU chassis directly to the BoB using our plug-in modules, cabling is minimized, creating a more compact reliable design and improving signal integrity.
-
product
Active Dual Loop Antenna
KH30936
Beijing KeHuan Century EMC Technology Co,.LTD
KH30936 active dual loop antenna is used for adjusting, testing, measuring and other receivers. It has many advantages:1. The antenna coverage frequency is wide: 150KHz ~ 30MHz .2. The field strength value is measured according to the correction coefficient within the effective frequency range, which is convenient to use.3. The antenna power is supplied by the host, which is convenient for outdoor measurement.4. Compared with the single loop antenna, the advantage is to read the maximum value directly, which eliminates the tedious steps of rotating the antenna to find the maximum value and the interference of the human body to the signal.
-
product
Loop A Line
TX916
The Loop a Line has been a Telstra standard for 20 years. It is probably the simplest time saving device available for contractors and technicians. Once fitted to the far end of a line you can switch between Open, Short, Connect, 600 ohm, and Tone modes allowing all installation and fault location to be performed from the one end without having to go back and forward from one end of the line to the other.
-
product
Dual Loop Master Controller
The Xcite System Master Controller provides all dual loop functions needed for accurate closed loop control and display of the static and dynamic test variables, while producing the highest electro-hydraulic frequency response. At the heart of each Xcite System is the Master Controller, a compact electronic control package which provides all of the controls and displays necessary to operate a controlled force or torque exciter system. The Xcite Master Controller is unique in that it provides electro-hydraulic excitation over a broad frequency range, unprecedented by any previous electro-hydraulic excitation system. It achieves its great frequency range through the use of sophisticated circuitry, high voltage inputs to the servovalve and compression control of the dynamic feedback variable in addition to the conventional servo control of the static loop. Static parameters such as force or displacement may be matched with dynamic control variables such as force, displacement, velocity, acceleration or strain for maximum test flexibility.
-
product
Multi-Standard Local Loop Simulatorw/Optional AWGN Generator
458-LM-A1-30
FEATURES: Simulates 26 AWG PIC as specified in ANSI T1.417; Bandwidth DC to 30 MHz; Solution for ADSL, ADSL2, ADSL2+, & VDSL2 chip/modem/DSLAM testing;
-
product
Short Circuit Loop Impedance Meter
AMZC-306
Voltage measurement up to 750V and up to 250V with resolution 0,1V ; Measurements using Uni-Schuko adapter or test wires 1,2; 5; 10 and 20m ; Loop impedance measurement with resolution 0,01Ω and much more
-
product
Single Loop Controller
1460
he 1460 has been designed to provide immediate visibility to the operator. At a glance, the programmable displays will show you the measured variable, the set point and the parameter being edited, the number of cycles or time remaining, the recipe name and number and also whether the cycle is in a ramp or soak mode
-
product
Short Circuit Loop Impedance Meter
AMZC-304
Short circuit loop impedance measurement in networks with nominal voltage: 220/380V, 230/400V, 240/415V, with frequency 45…65Hz ; Short circuit loop impedance measurement with 15mA current, without triggering RCD. ; Detection of the replacement L and N in the socket and automatic swap in the meter
-
product
Loop Calibrator
6500 LC
Standard Electric Works Co., Ltd
● 4-20mA (1kΩ load, 24V Loop Supply).● 0.025% Basic Accuracy.● Simple Operation Interface.● Auto Ramp and Step Functions.● 0-20mA, 0-24mA selectable.● Incremental percentage setting : 0-100%.● Warning beeper when output is open.● 0-24V output.● The minimum load of 20kΩ on voltage mode.
-
product
Loop powered Moisture Analyzer
PLMa
Multifunctional Multi-Purpose Cost Effective, easy-to-use dew point sensor, dew point probe
-
product
Loop / PFC Testers
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2715 is a loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.