Voltage Transformer
a type of intrument transformer enabling secondary connected metering.
-
Product
Loading Transformer
CL-6
-
This readily portable Knopp Loading Transformer weighs only 60 pounds and measures 12″ long, 9″ wide, and 10″ high. Its sturdy enclosure provides protection and adequate ventilation. Two convenient carrying handles are provided. The insulating terminal panel is rigidly secured to the transformer frame, and heavy-current, bus-bar-type terminals are securely bolted to the panel. The two outpout terminals each have two connection surfaces, one on a vertical plane and one on a horizontal plane, for maximum convenience in connecting the heavy current leads and in changing, when necessary, the series-parallel links. The links and the output connections cannot interfere with each other. All terminals and connection links are plated
-
Product
Transformer Heat Run Tester
-
1. Suitable for all transformers below 240MVA heat run test and winding resistance testing.2. Printing heat run data automatically.3. With double power supply, can test high voltage side and low voltage side simultaneously and test any operation respectively.4. With anti breakage protection function of inductive test items.
-
Product
Battery Voltage Supervisor
BVS
-
DV Power battery voltage supervisor – BVS, is an accurate battery voltage monitoring system that monitors the state of health of battery systems. It records important battery parameters such as battery voltage, inter-cell connection voltage, and ambient temperature. Because of that, it can be a support tool for capacity testing.The BVS voltage supervisor is an integrated system consisting of:BVS Control Unit (BVS-CU)Cell Voltage Modules (CVM)String Voltage Module (SVM) (optional)String Current Module (SCM) (optional)It is an ideal testing tool for maintenance, troubleshooting and performance tests on individual stationary batteries and battery packs in critical backup energy solutions.BVS-CU provides ambient temperature measurements on multiple locations (4 temperature channels). Overall string voltage and string current monitoring can be achieved by using an optional string voltage module (SVM) and string current module (SCM).There are two types of DV Power battery voltage supervisors:BVS – One cell voltage module measures 1 cellBVS-4 – One cell voltage module measures 4 cellsCVM modules detect cells that fail a discharge test based on monitored voltage values. As a result of that, these cells can be safely removed from the battery string.Data acquisition and analysis of data collected from the modules are available in the DV-B Win application software suite. They provide data viewing, tracking, and generation of comprehensive reports.
-
Product
AC Voltage Detector
-
Triplett Test Equipment & Tools
high performance AC Voltage detector with adjustable sensitivity that has a wide measurement range of 25 to 1000ACV, Dual Color Tip to indicate low/high voltage, built-in flashlight and durable overmold. The high sensitivity allows it to detect low voltage AC wiring commonly found in doorbell circuits, thermostats, control circuits, and video surveillance camera power. The Sniff-It 3 is designed for industrial applications with its impact and drop resistance in a sleek ergonomic design, and the easy to use thumb wheel helps dial-in detection range. Includes (2) AAA batteries. CAT III safety rating.
-
Product
Injection Transformer
J2100A
-
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
Product
Transformer Winding Resistance Meters
TWA Advanced Series
-
The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.
-
Product
Voltage and Continuity Testers
-
Amprobe voltage and continuity testers have built-in shakers for fast, easy troubleshooting with CAT IV 600V/CAT III 1000V input protection. To safely detect voltages up to 122kV without contact to the current carrying conductor, choose an Amprobe high-voltage tester. These intrinsically safe tools are ideal for industrial, utility, and mine applications.
-
Product
Split type AC Current Transformer
CTS-300
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*5A output for metering application.*Short circuit switch for secondary output is provided for safe operation.*High accurate transformer for the application of first class meter.*Easy to install by metal fitting.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TT Series
-
RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
FD-11603, 8-Channel, ±10 V Voltage Input Device for FieldDAQ
785639-01
Voltage Input Module
The FD-11603 can measure up to eight channels with a voltage input range of ±10 V. It features 24-bit resolution with simultaneous sample rates up to 100 kS/s. The FD-11603 offers channel-to-channel isolation, which eliminates noise from ground loops and protects instrumentation circuitry from high-transient voltages. The FD-11603 has an ingress protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11603 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11603 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11603 is ideal for test cell and outdoor environments.
-
Product
Instrument Transformer Test Systems
-
Our systems for testing voltage (VT) and current (CT) instrument transformers are conceived among other things for testing accuracy and insulation.
-
Product
Transformer Winding Resistance Meter
XWRM-10
-
The Motwane Manufacturing Company
The Motwane make XWRM-10 is a dual channel 10A rated, Transformer Winding Resistance Meter designed and developed aftere xtensive research on challenges and requirements of testing of various Transformer winding resistance. The instrument has One Current channel and two Resistance Channels. The instrument provides a large open circuit voltage of 42Volts, for fast charging of the highly inductive windings of transformers, to provide stable resistance values in minimum time. The XWRM-10 is intended to replace complex bridge set up with a single compact instrumentThe XWRM-10 is based on 4-wire measurement methodto measure low resistance accurately. The instrument iswell protected against inductive kickbacks offered by theinductive windings and gives stable reading on varioustypes of transformers.
-
Product
Current Transformer
ST-60CT
-
Standard Electric Works Co., Ltd
● 400/5A - 800/5A● 7.5-10V A● Class 1● Insulation 600V
-
Product
Voltage Probe
KHZ43201
-
Beijing KeHuan Century EMC Technology Co,.LTD
The KHZ43201 voltage probe is a standard low resistance test probe, which meets the technical requirements for this product in the CISPR16-1 and CISPR14-1 test equipment. When measuring the interference voltage of the power grid, the artificial power supply network cannot be used at the load port, and sometimes it is necessary to use a voltage probe to measure the interference of the signal port, the load port, and the antenna port. The input impedance of the voltage probe to the ground wire is greater than 1.5KΩ, which can protect the input terminal of the receiver.
-
Product
Burn Down Transformer
ATG 6000
-
Cable fault location with the BAUR ATG 6000. The high performance ATG 6000 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 5.75 kVA stray field transformer delivers a maximum voltage of 15 kV and is housed in a fully enclosed 19" housing.* Proven methodes for cable faults that are difficult to locate* Useful for cables that are difficult to access* Robust construction for reliable functions* Independent current and voltage control on each burning level
-
Product
Voltage Controlled Oscillators
-
a High Reliability Low Noise Voltage Controlled Oscillator (VCO) which covers a 10 MHz to 20 MHzfrequency band with a voltage tuning range from 0V to 20V. This design features exceptional phase noise performance of -120dBc/Hz @ 10 kHz offset. Supply Voltage is +15V with a generated output power level of +10 dBm and 2nd harmonic output of-11 dBc typical. The assembly is RoHs compliant and available in a compact 0.5 inch SMT package with an industry standardmounting footprint. The bottom surface is copper clad with 2-5 micro inches of immersion Gold over 150 - 250 micro inchesof Electro less Nickel which makes it resistant to oxidation for ease of soldering. The VCO operates over a temperature rangeof -40°C to +85°C and is designed to meet a variety of MIL-STD-202 test conditions including Humidity, Shock, and Vibration.
-
Product
BMS Transformers
-
In large battery pack applications with daisy chain connections, the number of cells connected in series is very high, and the large voltage differences demand component-to-component isolation. The serial communication links between boards need to be isolated by transformer coupling circuits instead of capacitor coupling.
-
Product
Voltage Amplifiers
-
Switchable gain up to 100 dB (x 100,000)Bandwidth DC to 100 kHzDC-drift 0.6 µV/°CInput noise down to 0.4 nV/√HzSwitchable AC/DC-couplingLocal and remote controlInput impedance up to 1 TΩ
-
Product
Transformer Winding Resistance Tester
KRI 9310
-
KRI 9310 adopt Kelvin four-wire testing method, which effectively eliminates the influence of the resistance of the test line on the test results. It can be able to increases the current to 10A by which can test extremely low resistance to 0.01 Ω(such as amorphous alloy, Copper-nickel, nickel-chromium-iron, iron-chromium-aluminum etc). For the tested objects with high resistance value (CT/PT), the instrument can extend the range to 20 kΩ,so the wide resistance test range enables KRI9310 can cover 80% of the power transformer products on the market and switchgear bus-bar cable etc. The power of the tester use the built-in rechargeable lithium battery that can test hundreds of transformers by one time charging.
-
Product
Voltage Indicators
-
*Measures voltage from 100V to 138kV line‑to‑line.*Can be used individually as voltage indicators or together for phasing operations up to 100 ft (30 m) apart.*Two LED displays are automatically synchronized during phasing operations.*Clear in-phase and out-of-phase indication.*Versatile for overhead and underground applications.*Capacitive Test Point and Peak Hold modes
-
Product
Non-Contact Voltage Detector
273 HP
-
Standard Electric Works Co., Ltd
2 ranges for selection : LOW 50V~1.5kV, HIGH 1.5kV~132kV. There is no power consumption in off mode : 0uA. Nice mechanical slide switch for function selection : HIGH / OFF / LOW. The power consumption in low voltage detection mode : Less than 20mA. The power consumption in high voltage detection mode : Less than 20mA. Bright LED and audible alarm sound when voltage is present. Lightweight, robust and compact. Efficient and easy to use. Users have to use the Hot Stick when test high voltages between 1.5kV~132kV. SEW provides nice optional accessories of Hot Sticks HS-175 and HS-120 for high voltage detection. Optional accessories : HS-175 Telescopic hot stick (triangle-type) and HS-120 Hot stick.
-
Product
Automatic Transformer Test System
TH2840BX
-
Changzhou Tonghui Electronic Co., Ltd.
■ The test speed is as high as 1000 times/s (>10kHz), without relay action time ■ Test level up to 20Vrms ■ The bias voltage is built-in ±40V/±100mA/2A ■ Up to 288 test pins (only TH2840NX) ■ Industry-friendly user experience: Linux bottom layer, built-in help file
-
Product
Low Voltage Detectors
LVD-17
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled smart voltage detector.● Bright LED and audible alarm sound when voltage is present.● Designed for non-contact voltage detection.● Sensitivity adjustable with thumbwheel.● Adjustable for use on power wiring plus lighting, thermostats and other low voltage circuits.● LED indication for battery condition.● Identify Hot and Neutral.
-
Product
Transformer Testers
-
*Quickly tests deenergized power distribution transformers*Briefly energizes the transformer and takes a snapshot of the condition by measuring the voltage, current and power factor of the test signal*Tests overhead, pad-mount and distribution transformers*Audible alarm confirms successful test*Improve SAIDI statistics by quickly testing and getting the transformer back in service*Auto self-test performed with every test*Compact, lightweight and easy-to-use
-
Product
Transformer Testing Panel
VTTP
-
Capable to Test Up to 25 MVA (Other Ranges are Available On Request). Useful for No Load Test (O.C.), Load Test (S.C.), DVDF Test HV Test of Transformer. Mains indication by R,Y,B indication Lamp. Over voltage, over current protection.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
-
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
Product
Voltage Testers
-
The non-contact voltage tester detects live conductors on cable connections, cable drums, sockets, switches, junction boxes etc. Due to capacitive measurement procedures, no current flow is required and interruptions can be indicated quickly and accurately.
-
Product
Non-Contact Voltage Tester
NCVT-3
-
Provides non-contact detection of AC voltage.Detects 12 – 1000V AC with simultaneous visual and audible voltage indicators.Bright flashlight illuminates work area and may be used independent of voltage detection function.Visual LED bar graph indicates the presence of voltage – the higher the voltage sensed, or the closer to the voltage source, the more LEDs light up.Bar graph visual voltage indicator utilizes up to five vibrant LEDs for easy interpretation/viewing.Audible voltage indicator beeps at a greater frequency the higher the voltage that is sensed, or the closer to the voltage source.“Auto Power-Off” conserves and extends battery life.Screw-thread battery cap with O-ring ensures protection against dust and water ingress.Lightweight, compact tool with pocket clip provides convenient storage and quick access.IP67: Dustproof and waterproof.6.6 feet / 2 meter drop protection.CAT IV safety rating for 1000V.Conforms to CE requirements.