PT
a type of intrument transformer enabling secondary connected metering.
-
Product
Enlarge Environmental Chamber
REXMED REC-480
-
MOD. REC-480, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 5,270 Watts, 18,000 BTU/hr, 4,545 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
Product
General Purpose Lab Oven
REXMED ROV-180
-
MOD. ROV-180, AC 110/230V, Plug type: , General purpose lab oven, dry air / hot air sterilizer, HS CODE: 841780, UNCCS CODE: 447483, UMDNS CODE: 14410, Main construction: powder coated steel and SS304, Controller: Microprocessor based PID controller, water proof keypad with timer, ˚C/PV and ˚C/SV display and setting, Timer: 9999/min, 9999/hr, Timer has DELAY_ON and DELAY_OFF function and at the end of operation audio and visual warning, Working range: Ambient +5˚C~250˚C, Stability at 37˚C: ±0.2˚C, Uniformity at 150˚C: ±1.5˚C, Sensor: PT 100Ω, Temperature audio and visual warning for AL-H and AL-L and OFS correction setting, Heater: 600W X 2pcs, Chamber: L40 X W40 X H50cm, Capacity: 80L, chamber with key lock, W/S: shelf X 2pcs
-
Product
Environmental Chamber
REXMED REC-280
-
MOD. REC-280, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
Product
Dual MAX31865 PT-1000 RTD to Digital Breakout
SEN-30202-PT1K
-
Dual channel breakout board for the MAX31865 RTD-to-Digital converter from Maxim. Two breakout hardware configurations are available standard, designed to interface with either the PT100 or PT1000 platinum RTDs. For non-standard applications, including thermistors, custom hardware configurations can be accommodated. Contact Technical Support for more information.
-
Product
Turns Ratio Testing
-
The transformer turns ratio test, or TTR test, confirms that the transformer has the correct ratio of primary turns to secondary turns. Using this test correctly can help to identify tap changer performance, shorted turns, open windings, incorrect winding connections and other faults inside transformers. Megger’s range of TTR testers are robust to withstand the harsh conditions that some transformer testing in. The range includes varying features to simplify and speed up testing as well as 3 phase TTR testers and PT and CT TTR testers.
-
Product
Enlarge Environmental Chamber
REXMED REC-450
-
MOD. REC-450, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,644 Watts, 12,433 BTU/hr, 3,140 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
Product
Solid Electrode Spectrochemical Cell
-
The spectroelectrochemical cell enables acquisition of infrared and Raman spectra of working electrode discs (variable sizes, up to 10 mm OD) under flowing solution. Working electrodes available include: Pt, Au, Ag, Cu, glassy carbon, etc. The cell uses a Pt-wire counter electrode and a Ag/AgCl reference electrode. For use with the EZpump peristaltic pump. Adapts to the Harrick Praying MantisTM Diffuse Reflection Accessory.
-
Product
Switch Module
STCS
-
The external module STCS allows performing automatically the following PT tests: ratio per tap; winding resistance; OLTC dynamic test. The connection to the transformer under test, to STS and to the measurement taps is performed just once; then, all transformer tests are performed without interruptions.
-
Product
Disk Peel Tester
DRK186
-
Shandong Drick Instruments Co., Ltd.
DRK186 Disk peel tester is applied to test the ink layer bonding strength of plastic film printing and PT print. To test the surface adhesion state of vacuum coating, surface coating, composite process.
-
Product
Pitot Static Indicator
ADSE 740
-
The ADSE 740 is a complete high performance dual pressure Ps and Pt standalone test bench specially designed to be used in the workshop or in the laboratory to test and calibrate all air data equipment such as altimeters, vertical speed indicators, air speed indicators, MACH-meter, air data computers ...) and sensors.
-
Product
Temperature Data Logger with K type Single Channel
VA601-TK
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Multifunction data logger with K J PT type current .voltage : K.J . PT100. PT1000. mADC. AAC. VDC.VAC.
-
Product
Winding Resistance Test
20A DC booster
-
The 20A DC STCS booster allows to perform resistance tests on a PT with a current up to 20 A DC. The option is used together with STS 5000 and STS 4000 and must be connected to STCS module.
-
Product
Environmental Chamber
REXMED REC-200
-
MOD. REC-200, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 1,892 Watts, 6,455 BTU/hr, 1,630 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
Product
WaveLink Dx10-PT Adjustable Positioner Tip Kit. Includes XYZ Positioner Assembly
Dx10-PT-KIT
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Hybridization Oven
REXMED ROV-200
-
MOD. ROV-200, AC 110/230V, Plug type: , Hybridization oven, HS CODE: 841780, UNCCS CODE: 484352, UMDNS CODE: 14410, Main construction: powder coated steel and SS304, Controller: Microprocessor based PID controller, water proof keypad with timer, ˚C/PV and ˚C/SV display and setting, Timer: 9999/min, 9999/hr, Timer has DELAY_ON and DELAY_OFF function and at the end of operation audio and visual warning, Working range: Ambient +5˚C~85˚C, Stability at 37˚C: ±0.1˚C, Sensor: PT 100Ω, Temperature audio and visual warning for AL-H and AL-L and OFS correction setting, Heater: 1KW, Shaking timer: 999/min, 999/hr, shaking timer can be set in second, minute or hour function and at the end of operation audio and visual warning, Motor: Noiseless powerful brushless induction motor 15W, Rotation: 5~60rpm adjustable, Rotator: for 8pcs(optional), Reciprocal: 5~60rpm adjustable, Platform: L30 X W18cm(optional), Rocker: 5~60rpm adjustable, Platform: L29 X W22.5cm(optional), Chamber: L35 X W25 X H25cm, Capacity: 21.9L, chamber with glass viewing window, Optional: Rotator for 8pcs X 1set, reciprocal platform (L30 X W18cm) X 1set, rocker platform (L29 X W22.5cm) X 1set
-
Product
PS/PT ADAPTOR KIT
PSAT
-
PSAT UNIVERSAL Ps is a static adaptor for virtually ANY KIND OF AIRCRAFT.PSATUNIVERSAL Ps is very easy to use on the plane: power ON the Succion Unit place the Universal adapter on the aircraft and adjust the Ps port release the Security Valve (blue): You are ready to test your static port !Pneumatic insulation is made with rubber tube. PSAT UNIVERSAL Ps is fittedwith a quick connector, which allows to use the adaptor as a cap for special tests.
-
Product
CT / PT Analyzer
CTPTA-504
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
UDEY ‘CTPTA-504 is a comprehensive CT and PT analyzer. It’s constant voltage and current is highly stable. DSP system controls the constant voltage and current source output and amplitude. This source generates AC of 0-125V and or DC of 0-0.5A current to sample CT. The DSP system besides controlling the sources, also samples data and communicates with the internal computer. Display screen is large LCD with touch pad. The analyzer is highly accurate with high noise immunity and is very user friendly.
-
Product
Transformer Testing Equipment
-
Offering you a complete choice of products which include Automatic Transformer Turns Ratio Instruments (ATRI- 3), Automatic Transformer Turns Ratio Instrument (ATRI-201), VTRI-2000 ( Transformer turns ratio instrument ), Current Transformer Test Set (CTC-1), Potential Transformer Tester ( PT Tester ) and Current Transformer Tester ( CT Tester ).
-
Product
Instrument Transformer Calibrators
CTPT 81
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
Product
Hybridization Oven
REXMED ROV-201
-
MOD. ROV-201, AC 110/230V, Plug type: , Hybridization oven, HS CODE: 841780, UNCCS CODE: 484352, UMDNS CODE: 14410, Main construction: powder coated steel and SS304, Controller: Microprocessor based PID controller, water proof keypad with timer, ˚C/PV and ˚C/SV display and setting, Timer: 9999/min, 9999/hr, Timer has DELAY_ON and DELAY_OFF function and at the end of operation audio and visual warning, Working range: Ambient +5˚C~85˚C, Stability at 37˚C: ±0.1˚C, Sensor: PT 100Ω, Temperature audio and visual warning for AL-H and AL-L and OFS correction setting, Heater: 1.2KW, Shaking timer: 999/min, 999/hr, shaking timer can be set in second, minute or hour function and at the end of operation audio and visual warning, Motor: Noiseless powerful brushless induction motor 15W, Rotation: 5~60rpm adjustable, Rotator: for 8pcs(optional), Orbital: 20~250rpm adjustable, Platform: L30 X W20cm, Chamber: L35 X W25 X H42.5cm, Capacity: 37.2L, chamber with glass viewing window, Optional: Rotator for 8pcs X 1set
-
Product
Current Transformer Analyzer/Tester
GF1061
-
Beijing GFUVE Electronics Co.,Ltd.
Portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to download data or RS232 port to PC control. This model GF1061 CT PT analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE C57.13 and IEC60044 & IEC61869 standards.
-
Product
Platinum RTD Sensor - PT100 - 3 Wire 1 meter long
-
For precision temperature sensing, nothing beats a Platinum RTD. Resistance temperature detectors (RTDs) are temperature sensors that contain a resistor that changes resistance value as its temperature changes, basically a kind of thermistor. In this sensor, the resistor is actually a small strip of Platinum with a resistance of 100 ohms at 0C, thus the name PT100. Compared to most NTC/PTC thermistors, the PT type of RTD is much most stable and precise (but also more expensive) PT100's have been used for many years to measure temperature in laboratory and industrial processes, and have developed a reputation for accuracy (better than thermocouples), repeatability, and stability.
-
Product
Dual MAX31865 PT-100 RTD to Digital Breakout
SEN-30202-PT100
-
Dual channel breakout board for the MAX31865 RTD-to-Digital converter from Maxim. Two breakout hardware configurations are available standard, designed to interface with either the PT100 or PT1000 platinum RTDs. For non-standard applications, including thermistors, custom hardware configurations can be accommodated. Contact Technical Support for more information. RTD devices may be wired in 2, 3 or 4-wire configurations using the 4-pin screw terminal input. The MAX31865 breakout is interfaced via 3 or 4-wire SPI with a data-ready output for specific operating modes. An LDO and a high-speed level shifter are included to allow interfacing with microcontroller devices between 3.0V and 5V (all Arduinos, Raspberry PI, etc) without sacrificing device performance.
-
Product
Aircraft Simulator
ePlane PC
-
Pneumatic connections Ps, Pt and AoA (option)High accuracy, high resolutionSelectable pressure units: hPa; mb; in Hg; mmHg; ft; m; kts; km/h, ft/min; and Mach number and needle equipment visualisationSoftware executable under Windows 2000 and XPUSB cable for PC connection
-
Product
IGBTs
-
ST offers a comprehensive portfolio of IGBTs (Insulated Gate Bipolar Transistors) ranging from 300 to 1700 V, both in planar punch-through (PT) and trench-gate field-stop (TFS) technologies. IGBTs belong to the STPOWER family.
-
Product
Environmental Chamber
REXMED REC-400
-
MOD. REC-400, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,506 Watts, 11,962 BTU/hr, 3,020 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
Product
Temperature Data Logger with K J PT type
VA601Series
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Multifunction data logger with K J PT type current .voltage : K.J . PT100. PT1000. mADC. AAC. VDC.VAC.
-
Product
Cable and Pipe Locator
PT-14
-
The locator PT-14 is used as an induction signal receiver in a cable tracing and fault location set for the following applications:• tracing – finding the route and determining the burial depth of underground cables and other hidden utilities;• fault location – pinpointing interphase and phase-to-sheath short circuits faults;• cable identification – identifying a correct cable from a bunch.
-
Product
Digital Multimeter
PT-30
-
Standard Electric Works Co., Ltd
Lightweight, compact, and easy to use. 4000 counts. Full automatic measurement, voltage measurement, resistor measurement. Data hold function. Auto off function. Continuity check. Diode measurement. Low battery indication. Pen light provided. Backlight LCD. 3V DC power supply.
-
Product
100base-T1 Ethernet (BroadR-Reach®) Logging Expansion With Low Latency
PT-15B
-
The PT-15B expands the PM-200 data logger from the Power Family by adding twelve 100base-T1 interfaces. Ethernet traffic is looped through the device with constantly low latency irrespective of the frame length. This means that the time synchronization protocols of the logged Ethernet interfaces are not affected. 100base-T1 packets are time stamped, filtered and sent to the PM-200 data logger via a 1000base-T interface.