Sound Calibration
assure sound measurement accuracy.
See Also: Sound Calibrators, Acoustic Calibration, Sound, Microphone Calibration
-
product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (f) 50 Ohm
CK521A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
Sound Impact Sensor
29132
The Sound Impact Sensor detects sound from up to 3 meters away. This human input device lends noise-activation possibilities to your microcontroller projects.
-
product
Four Channels Sound and Vibration Analyser
SVAN 958A
The SVAN958A is an unique four-channel instrument offering 20kHz-band sound & vibration analysis. It is a perfect choice for all applications that require simultaneous class 1 noise measurements & tri-axial vibration assessment. Each of four input channels can be independently configured for sound or vibration detection with different filters and RMS detector time constants giving users an enormous measurement flexibility. The real advantage of SVAN958A is the capability to perform advanced analysis simultaneously to the level meter mode.
-
product
Calibration
Field Probes
We calibrate following types of field probes:Electric field probesMagnetic field probesFlux density metersRadiation monitorsNear field probes
-
product
Dry Block Calibrators
Nagman Instruments & Electronics Pvt. Ltd
Dry Block calibrators are used for the most accurate calibration of temperature devices. Ideal for quick / fast Site Calibration of RTDs / Bi Metal Thermometers, Temperature Switches / Indicators etc. in Industrial & Marine Applications. Dry block calibrators can be used for a very wide range of temperature from – 100°C to over 1500°C. Nagman hosts a range of calibrators that are Stable, portable, heavy duty and budget friendly.
-
product
Seismic Transducers Calibration System
Calibration of the seismic sensors should be conducted in the low-frequency domain, which means, that the relative method used for calibration of the vibration transducers is not applicable since it does not guarantee the required accuracy level. The problem is that the reference accelerometers have uneven AFR characteristic in the low-frequency domain. Thus, calibration of seismic transducers requires implementation of a different approach.
-
product
Calibration & Repair Services for Instruments in Process Control
Meeting customer needs is our number one priority. Hastings Instruments offers free technical support as well as personalized one-on-one customer service through a diverse organization of field Customer Service Representatives and Distributors. We have more than 50 field Customer Service Representatives that are situated to provide local support throughout the world.Additionally, reaching our Customer Service Department is only a toll-free number away (USA) and is available for your convenience. Faxing or E-mailing your question first will assure that it is reviewed before you speak to a Customer Service Representative. Also, following the steps listed in our trouble shooting guides (included in each product instruction manual) may help direct you to the appropriate department before you pick up the phone to call.
-
product
Trace-Level Dilution Calibrator
Model T700U
Teledyne Advanced Pollution Instrumentation
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.
-
product
Standard Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036B
The Keysight 85036B calibration kit contains precision 75 ohm type-N standards used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 3 GHz.
-
product
PXIe-4499, 204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module
781370-01
204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module - The PXIe‑4499 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4499 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4499 delivers simultaneous sample on all channels. In addition, the PXIe‑4499 includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
product
Calibrated, Integral Isolator Noise Sources
Calibrated, Integral Isolator Noise Sources by Pasternack
-
product
Humidity Calibration Set
The humidity transmitters as all other measuring instrumentsshall be periodically checked and eventually adjusted. The most simple solution for this purpose is the E+E calibrationset.
-
product
Calibration Light Sources
An adjustable mount for Sciencetech''s line of calibration pen lamps.Power supply and pen lamp are not included. See the calibration sources brochure for more information.
-
product
Calibration Services
We offer a full range of calibration services and repairs. Our Indianapolis calibration laboratory is accredited in accordance with the recognized international standard ISO/IEC 17025 (2017) and meets the requirements of ANSI/NCSL Z540-1994-1. Alternatively, our network analyzers and calibration kits can be calibrated by any ISO17025-accredited and Z540-1 compliant calibration lab worldwide.
-
product
Dry Block And Bath Calibrators
These units are used to calibrate sensors such as thermistors, thermocouples and RTD's. Different temperature ranges, accuracies and stabilities to cover most sensor specifications.
-
product
Sound Level Meter, 40 dB, 130 dB, 3.5 dB, 0.1 dB, 40 °C, 0 °C
72-935
The 72-935 is a Compact Digital Sound Level Meter, measures less than 6-inch length, including the windscreen and provides full 40 to 130dB measuring range. Perfect for numerous types of measurement including sound system testing and noise level monitoring.
-
product
Phase Noise Generator / Calibrator
PNG-A
Noise eXtended Technologies S.A.S.
The PNG-A is a high precision generator used in Test and Measurement instruments calibration. It is a Signal Generator with precisely computed phase and amplitude noise characteristics. With its wide frequency offset range, 1Hz to 1 MHz offset, and its programmable Phase and Amplitude noise in real time, this is the ideal standard to calibrate phase noise analyzers, Signal Source Analyzers and Spectrum Analyzers.
-
product
ECPR System (Electrically Calibrated Pyroelectric Radiometer)
Rs-5900
Developed in conjunction with NIST, the Rs-5900 ECPR is a ±1% absolute accuracy radiometric transfer standard for the visible to near-IR (0.25-2.0µm), with the RsIR Option extending the ±1% accuracy to >20µm. The RsP-590 Pyroelectric Probe requires no cooling and maintains ±1% accuracy from 1 µW to 100 mW. The ECPR uses an auto-nulling, electrical substitution technique that allows the instrument to be referenced against NIST electrical standards, insuring maximum accuracy and precision. Unlike most electrically calibrated radiometers, there is a direct correlation between electrical and optical heating because the same material serves as both the optical absorber and electrical heating element.
-
product
Calibrated Pocket Magnetometer
M 25
Instruments available in 8 different, Full Scale, Gauss Ranges.
-
product
Zero Gas Generator - Calibration of Ambient Air Monitoring Systems
ZNV-7
HORIBA Europe’s Zero Gas Generator ZNV-7 has been developed to check the zero point and dilute the span gas sources in order to carry out the calibration of ambient air monitoring systems. The increasing sensitivity of ambient air analyzers is required by strict official guidelines, which demands pure and dry air in a sufficient quantity at constant pressure.
-
product
Humidity Calibration
Trescal provides full Humidity Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Humidity Calibration services can be delivered at your site or at our lab. Accreditations for our humidity calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
product
RF Electronic Calibration Module (ECal), DC/300 KHz To 26.5 GHz, 4-ports
N4433D
The Keysight N4433D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4433D is a precision 4-ports ECal module that supports selection of 3.5 mm connector and can be mixed up to 26.5 GHz. Select either female-female, male-male, or female-male connectors.
-
product
Laser Calibration System, Superior Accuracy, Portability and Reliability
5530
The configurable system offers all the components you need to perform a variety of measurements using the USB on your PC as the host controller and power source. For basic linear measurements you will need the USB Axis Module, USB Sensor Hub, Air and Material Sensors, Sensor Cables, Software, Laser, Laser Cable, Remote Control (optional)and the Linear Optics Set. Other available options include the Laser Tripod (with laser mounting plate), optics and fixturing kits for making additional types of measurements, and wheeled transit cases.
-
product
Velocity Calibration
Trescal provides full Velocity Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Velocity Calibration services can be delivered at your site or at our lab. Accreditations for our velocity calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
product
Calibration Management Software
Regardless if you are a commercial calibration company performing services for your clients or a in-house calibration organization working to meet your internal customers requirements, Qualer provides companies best in class functionality with our Calibration Management Software for the management and performance of calibrations and maintenance. Qualer’s Calibration Management Software Cloud infrastructure enables calibration and documentation to be processed in real-time, increasing efficiencies and productivity, while reducing costs.
-
product
Sound Level Meter
SM-2
Monacor International GmbH & Co.
Sound level meter (class 2), one-hand operation. Electret microphone capsule. Max hold and data hold function. A and C rating, slow and fast. Additional output for DC/˜V via 3.5 mm jack. Supplied with a practical nylon carrying bag.
-
product
Conformance Calibration Standard Test Card for GS1-128 Symbol Verifiers
AI-CCS-128-E Rev B
This test card is ideal for testing of verifiers, scanners, and other GS1-128 barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
product
infra-red turbidity bench meter (NTU) with calibration kit
CyberScan TB 1000
The CyberScan TB1000 series turbidity meters (employing the Nephelometric non-ratio or NTU principle) are designed to meet stringent requirements of today's scientists. TB1000 series meet the performance criteria specified by USEPA method 180.1 for NTU measurement and ISO 7027 (IR version). Ideal for beverage production, drinking water, waste water treatment, petrochemical and electroplating applications.
-
product
Multi-Cal Benchtop Calibrator
MC6
Model MC6 Multi-Cal Benchtop Calibrator performs a wide variety of simple and complex pressure based measurement, test, and calibration operations. Modular sensor design allows user to select pressure measurement range for application flexibility
-
product
Partial Discharge Measurement Calibrator
DAC-CP-2
DAC-CP-2 is a calibrator for partial discharge measurements. The electric charge enables to generate up to max 10000pC. It is battery-operated and can be charged by connecting to the measuring instrument (DAC-PD-3).





























