Loop backs
connect input to ouput to test I/O loop.
-
Product
Panel-mounted Power Amplifier(Hardware In The Loop Simulation)
PA30Bi
-
PA30Bi is the panel-mounted type real time simulation amplifier with three-phase current and four-phase voltage.
-
Product
Closed Loop Hall Effect Current Sensors/Transducers
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor
-
Product
Loop Powered Indicators
-
DEVAR loop powered indicators are designed to easily convert any standard 4 to 20mA loop signal to readout directly in engineering units. Optional back-lit display available.
-
Product
Loop Calibrator
6500 LC
-
Standard Electric Works Co., Ltd
● 4-20mA (1kΩ load, 24V Loop Supply).● 0.025% Basic Accuracy.● Simple Operation Interface.● Auto Ramp and Step Functions.● 0-20mA, 0-24mA selectable.● Incremental percentage setting : 0-100%.● Warning beeper when output is open.● 0-24V output.● The minimum load of 20kΩ on voltage mode.
-
Product
4-20mA Current Loop USB Data Logger
EL-USB-4
-
This data logger measures and stores up to 32,000 current loop readings over flashing red and green LEDs. The data logger features a pair of screw terminals and is supplied complete with a a 4-20mA d.c. measurement range. The user can easily set up the logging rate and start time, and download the stored data by plugging the module straight into a PCs USB port and running the purpose designed software under Windows 2000, XP or Vista
-
Product
Loop / PFC Testers
-
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2715 is a loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
Product
Panel-mounted Power Amplifier(Hardware In The Loop Testing)
PA60Bi
-
PA60Bi is the panel-mounted power amplifier, which can produce 3-phase current, with maximum RMS phase current of 60A and maximum output power of 800VA, and 4-phase voltage, with maximum RMS phase voltage of 120V and maximum output power of 60VA.
-
Product
PXI Analog Output/Current Loop Simulator Module - 4 Channel
41-765-004
-
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
mA Loop Calibrators
-
Loop Calibrators are indispensable tools for process calibration professionals and we have just one you need. Choose from three different models depending on your need for accuracy and intrinsic safety. Each one is feature-rich and simple to operate and read.
-
Product
Active Loop Antenna
AL-130R
-
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 4 Channel
43-765-004
-
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
PXI Analog Output/Current Loop Simulator Module - 16 Channel
41-765-001
-
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
PXI Analog Output/Current Loop Simulator Module - 12 Channel
41-765-002
-
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Open Loop Current Sensor
C03 30A
-
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
Product
Closed Loop Hall AC/DC Current Sensor
CYHCS-SH
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can beused for measurement of DC and AC current, pulse currents etc. The output of thetransducer reflects the real wave of the current carrying conductor.
-
Product
RCD Loop Line
-
Digital measuring instrument for RCD testing with Loop and Line resistance measurement also without tripping the RCD.
-
Product
Current Loop Data Loggers
-
This data logger can measure and store 4~20mA DC current readings automatically. The professional applications can be provided by the PC software DGraphTM. Logger status, alarm indication and low battery indication are via flashing red/green LED and yellow LED. The button on housing can be used to start logging, or confirm and clear LED alarm when LED alarm is hold status.
-
Product
Local Loop Simulator 128 Channels
458-CC-16/458-CM
-
FEATURES: Accepts 1 to 16 Line Modules; User-Friendly Interface; Multiple Configurations; Field-Upgradeable Software; One-Year Warranty/Calibration. The 458 Series 16-slot Chassis, which consists of the 458-CC chassis and one of three control modules, provides a wide variety of configurations through use of up to 16 plug-in Line Modules.
-
Product
Surge Suppressor to Suppress SCR Spikes from Customer Equipment Going Back to Utility Power, P/N 5965C
-
This Suppressor Board is ideal for SCR Controlled Power Supplies when SCR control is on the primary side.The Suppressor Board will prevent SCR spikes to go back into the 480 VAC utility power lines.
-
Product
Back Plane Tester
-
This machine is used to test back planes used in telecommunications central stations. An operator loads a completed point to point wired back plane onto a retractable shelf on the front of the tester. Table continues and the disk falls through a hole into the bin. The shelf is pushed back into the machine where it is held in place by pneumatic operated clamps. Then a series of pneumatic cylinders sequentially insert a test card into each location in the back plane. A remote instrument performs a complete point to point continuity, short and hi pot test on all connections in the back plane.
-
Product
Three Loop Antenna
VVLA-30M
-
The three loop antenna VVLA-30M is a standard measurement antenna according to CISPR15-2005/GB17743-2007 standard
, it can work with LISUN EMI-9KA / EMI- 9KB EMI Receiver System for EUT magnetic field radiation measurement between X, Y and Z planes. The antenna measurement is accurate, switch conveniently and it can completely replace imported products. -
Product
Mini Back Probes/Wire Piercers
618
-
*Great for backprobing weather pack style connectors used with numerous automotive sensors *Also very handy for piercing and tapping readings on smaller gauge wires - using the included probe adapters *Works with most Test Lead Kits in the field - with standard 4mm banana plug test lead *Set includes four probes - red, black, green, yellow Test probes 21 mm length
-
Product
Current Loop Supply Isolating Transmitter
Model TWS / TWS 2
-
Kusam Electrical Industries Limited
• Aux. Power AC 85 ~ 265V or DC 85 ~ 300V• High Accuracy 0.1% RO at 23 °C ± 5 °C• Output User Selectable• PC Plastic Case, DIN Rail or Wall Mounting• High Dielectric Strength (AC 1.5KV/Min, between Input / Output / Power)
-
Product
8 Connector-Hole Back Extension
9401-BE
-
Semi-enclosed version of the cabling "doghouse" for the Hawk/PC chassis with rear panel punched to accommodate 8 50/37 pin d-sub connectors. Space is provided to mount the standard DG-style 100 pin edge connector paddles.
-
Product
- RS-232 to Current Loop Converter
Model 65A
-
FEATURES: Active/Passive Loops; 20 or 60 mA. Operation; DC To 19.2 KBPS; Half/Full Duplex; Optically Isolated; DTE/DCE Selectable. The Model 65A is a small, versatile, RS-232 to Current Loop Converters for use with teletypes or computers providing local terminal input via a 20mA. (or 60 ma.) current loop. The Model 65 includes a wall mounted transformer and internal power supply circuitry.
-
Product
Pump Back Gas Analyser
Rapidox SF6 6100
-
The Rapidox SF6 6100 Pump Back is the latest in fully-automatic gas analysers, designed for controlling and monitoring the quality of SF6 in medium & high voltage gas insulated electrical equipment. Exceptional accuracy and stability are provided when measuring the purity of SF6 gas, through specially selected sensors.
-
Product
Antenna, Loop
EM-6871 | 30 Hz – 1 MHz
-
The EM-6871 Antenna can be used with any 50 ohm /Receiver/Field Strength Meter to obtain magnetic field measurements from 30 Hz to 1 MHz.
-
Product
High Current Short Circuit Loop Impedance Meter
AMZC-310S
-
Measurement of very small short-circuit loop impedances (with resolution of 0,1mΩ) using the current of 150A under 230V, maximum 280A under 440V, or measurement using the current of 23A under 230V, maximum 42A under 440V
-
Product
Closed Loop Precise Hall AC/DC Current Sensor
CYHCS-LF
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for accurate measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.