Multifunction Calibrators
An accurate temperature, pressure, frequency, voltage, current and other units of measure to facilitate their comparison to and adjustment of instruments.
-
product
Dry Block Calibrators
Nagman Instruments & Electronics Pvt. Ltd
Dry Block calibrators are used for the most accurate calibration of temperature devices. Ideal for quick / fast Site Calibration of RTDs / Bi Metal Thermometers, Temperature Switches / Indicators etc. in Industrial & Marine Applications. Dry block calibrators can be used for a very wide range of temperature from – 100°C to over 1500°C. Nagman hosts a range of calibrators that are Stable, portable, heavy duty and budget friendly.
-
product
Multifunction Instrument for Education and Training
LabXplorer
LabXplorer turns your desktop, laptop, tablet or smart phone into a powerful, multifunction test and measurement instrument for a wide range of applications. Instruments, whatever you need, are at your fingertips. LabXplorer provides multimeter, oscilloscope, spectrum analyzer, logic analyzer, programmable analog and digital signal generator, impedance analyzer and also measures characteristics of passive electronic components and semiconductor devices.
-
product
Calibrators
Handheld calibrator is an exceptional instrument performing precision measurement of pressure, temperature, current or voltage. The base unit includes application-specific firmware for convenient instrument calibration and logging of associated data. In addition, the ATE-2 has the ability to interface the system with a computer, data acquisition system or dumb terminal via the standard USB interface.
-
product
Economy Mechanical Calibration Kit, DC To 6 GHz, Type-N, 50 Ohm
85032E
The Keysight 85032E economy calibration kit contains a type-N male fixed termination and a one-piece type-N male open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 50 ohm type-N connectors. The kit is specified from dc to 6 GHz.
-
product
Portable Calibrator
MC141
Voltage range from 0 to 750 V DC/AC with uncertainty 0.01% Current range from 0 to 2 A DC/AC with uncertainty 0.02 % Calibrated sinusoidal output signal DC - 1kHz. Set standard resistors from 10 Ohm to 100 MOhm in decade values with uncertainty 0.02 %. TC temperature sensor simulation R, S, B, J, T, E, K, N in range from -250 oC to 1850 oC
-
product
Dual Channel Multi-function Decommutator
LS-55-DD
The Lumistar LS-55-DD PCI Dual Multi-function PCM Decommutator offers two multifunction decoms and two optional bit synchronizers (LS-45) in a single PCI card slot. The multi-function decoms are implemented in FPGA using a next generation design based on the LS-50-P. The simulators,decommutators, time code reader and time code generator are achieved on the main board and the bit synchronizer is achieved through a low-profile daughterboard. CVSD voice, h.261 video, and IRIG Chapter 8 decoding are achieved through software.
-
product
Traditional Handheld Refractometer Calibration
104XXVP Series
Two-point NIST Traceable Certified Calibration for the following refractometers: 10430VP, 10431VP, 10433VP, and 10440VP.
-
product
Multi-Cal Pressure Calibrator
MC
Series MC Portable Multi-Cal Pressure Calibrator performs a wide variety of simple and complex pressure based measurement, test, and calibration operations. Modular sensor design allows user to select pressure measurement range for application flexibility.
-
product
Multifunctional testers
MI 3152H EurotestXC 2,5 kV
MI 3152H EurotestXC 2,5 kV is an instrument from the new generation of Metrel’s multifunctional measuring instruments. The already well known functions like complete installation safety testing according to IEC/EN 61557 and AUTO SEQUENCE testing of TN and TT earthing systems expanded with insulation resistance measurement with the test voltage up to 2,5 kV are managed by a completely new user interface based on large colour touch screen display.
-
product
Calibration & Demag.
Model 8515-D
The Model 8515-D is a medium-energy, high voltage, and capacitor discharge type ringing demagnetizer capable of desaturating Ceramic and Rare Earth magnetic materials. The Model 8515-D is easily adapted to a wide range of production and laboratory demagnetizing requirements. A modern solid-state electronic control circuit, coupled with a rugged, heavy-duty discharge SCR and fixture, make this demagnetizer a highly reliable, low maintenance unit. The electronic voltage control circuit prevents the Model 8515-D from being discharged before the preset energy level has been reached, avoiding incomplete magnet desaturation. An easy to read front panel meter monitors the capacitor voltage. The energy storage level can be easily changed in the field. Integral electrical interlock and fail-safe circuitry provide a high degree of operator safety.
-
product
NIST Calibration for D610-A
D610-A-CCNIST
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
Pressure Calibrators
Wherever you need to work and whatever pressure range you need to work with, our broad selection of tools will meet your needs. From pneumatic or hydraulic deadweight testers and test pumps to electronic deadweight testers, bench controllers, and precise analog pressure gauges, we have you covered at the bench. Going into the field? Fluke’s portable pressure calibrators – with or without pumps and intrinsically safe or not – work with gases or liquids, source and measure, power transmitters, and cover a wide range. With individually available pressure modules, our portable and bench solutions cover pressures from vacuum to 10,000 psi.
-
product
Multiproduct Calibrators
Its innovative design utilises the latest in cutting edge digital and analogue electronics, combined with the latest manufacturing techniques to create the world's first ultra-portable full-function calibrator.
-
product
Calibrator Module
CAP CAL
The purpose of CAP-CAL is to check the correctness of Tan Delta and Capacitance of TD 5000 and TDX 5000. The calibrator includes an extremely high accuracy high voltage capacitor, which comes with a certificate issued by ISA - Altanova Group lab.
-
product
OTDR Training & Calibration Solution
In addition to network simulation applications, the Fiber Lab 800HE from M2 Optics is a professional optical fiber platform that enables technicians to practice using an OTDR to find splices, faults, or bad connections in a length of optical fiber. In addition to training, it can also be used by equipment servicing teams to calibrate OTDRs with fiber that includes pre-determined events at known points.
-
product
Multifunction Power Meters
KINGSINE Electric Automation Co., Ltd.
Big LCD display with Blue BacklightWide temperature rangeWide angle display
-
product
AC Power Calibrator
LS3300
The LS3300 is an AC signal generator capable of outputting both current and voltage simultaneously, thus allowing it to calibrate power meters. Providing output ranges of 10mV-1250V, and 0.3 mA to 62.5 A, and upto 78.125 kW, the unit is capable of calibrating up to 0.15 % Class Power meters. New features on the LS3300 include a high definition LCD display, a vector diagram, and the ability to synchronize up to three units to emulate anything from single phase two wire to three phase four wire systems.
-
product
ECU Calibration
Designing an Electronic Control Unit (ECU) is only the beginning. The features in ECUs, such as Powertrain Control Units, are quickly becoming more complex and offering more features. Thousands of variables are now provided for the engineer to modify during the in-vehicle calibration phase, and fine tuning them is as complicated as it is critical. Calibration tools significantly impact the efficiency and effectiveness of the ECU development process. These tools are typically comprised of PC-based software to perform the adjustment of the variables and an ECU hardware interface to provide the connection of the software to the controller. Teams must be able to measure and time-align relationships of inputs and outputs and make real-time modifications.
-
product
USB-6356, 8 AI (16-Bit, 1.25 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device
781444-01
8 AI (16-Bit, 1.25 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device - The USB-6356 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI-STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB-6356 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
product
Insulation & Multifunction Tester (LCD Display)
4153 IN
Standard Electric Works Co., Ltd
Microprocessor-controlled. Measures Insulation Resistance, voltage (AC-DC) measurements with automatic hold facility, diode, ohm, and continuity with a short circuit current of minimum 220mA. Auto-off function. Energy conservation feature. Ener-Save™ limit the test duration to about 10 Seconds. Quick Test and EnerSave™ are unique features. Both saves energy. No moving parts. All calibration are saved internally in a non volatile memory. Easy calibration at any facility around the world. Operates with rechargeable batteries, alkaline or low cost general purpose batteries. Low cost maintenance, calibration, and ownership. Complies to all the latest regulations, including UK.
-
product
Calibrators
Portable and user friendly calibrator, ideal for checking sound level meters and dosimeters on the measurement site, or in the laboratory.
-
product
Calibration Services
We offer a full range of calibration services and repairs. Our Indianapolis calibration laboratory is accredited in accordance with the recognized international standard ISO/IEC 17025 (2017) and meets the requirements of ANSI/NCSL Z540-1994-1. Alternatively, our network analyzers and calibration kits can be calibrated by any ISO17025-accredited and Z540-1 compliant calibration lab worldwide.
-
product
USB-6341, 16 AI (16-Bit, 500 kS/s), 2 AO (900 kS/s), 24 DIO USB Multifunction I/O Device
782250-01
16 AI (16-Bit, 500 kS/s), 2 AO (900 kS/s), 24 DIO USB Multifunction I/O Device - The USB‑6341 offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI‑STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB‑6341 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
product
Calibration Lead Precision Resistor - Single
40-975-009-SL1
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
product
Arrester Discharge Counter Calibrator
HTFZ-III / 451
Wuhan Huatian Electric Power Automation Co., Ltd.
Test whether the arrester of each type of arrester is operating normally.
-
product
USB-6361, 16 AI (16-Bit, 2 MS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device
782256-01
16 AI (16-Bit, 2 MS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device - The USB-6361 offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI-STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB-6361 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
product
NIST Calibration for D600A-AT.
D600A-AT-CCNIST
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
Hydraulic Calibration for Load Cell
HLCS-10000
Jinan Testing Equipment IE Corporation
The Hydraulic Calibration System is specially designed for the calibration of load cells with higher capacity. The Calibration for Load Cell can calibrate the load cell within +/-1%.
-
product
PXIe-7865, Kintex-7 160T FPGA, 24-Channel AO, 1 MS/s, PXI Multifunction Reconfigurable I/O Module
787355-01
PXIe, Kintex-7 160T FPGA, 24-Channel AO, 1 MS/s, PXI Multifunction Reconfigurable I/O Module - The PXIe-7865 features flexibility of timing and synchronization with a user-programmable FPGA for onboard processing and direct control over I/O signals. The PXIe-7865 provides 24 analog output, 2 analog input, and 32, 5V input-tolerant digital I/O channels connected to a Kintex-7 160T FPGA to help you design applications for hardware-in-the-loop testing, custom protocol communication, sensor simulation, and high-speed control. You can use the dedicated A/D converter (ADC) for independent timing, individual channel triggering, and multirate sampling. Additionally, the PXIe-7865 includes peer-to-peer streaming for direct data transfer to other PXI Express modules.
-
product
Phasor Measurement Unit Calibration System
6135A/PMUCAL
The 6135A/PMUCAL system is the only fully automated and traceable PMU calibration system available today. It fully complies to the IEEE C37.118.1™-2011 and section 7 of IEEE C37.242:2013 standards for PMU operation and verification.





























