Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39H-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Low Frequency Vibration Signal Conditioner
-
A compact Signal Amplifier to make optimal signal processing being connected with the Servo type Accelerometers. It is used for Vibration Acceleration Measurement, Waveform Observation, for various Analysis in combination with the AC Voltage Meter, Oscilloscope, FFT Analyzer respectively. Furthermore, Voltage signals from the Microphones or Sound Level Meters can be output to the instruments like Recorders along with the Vibration Signals.
-
Product
Automated Resistance Standard
SmartResistor
-
The SmartResistor combines, into one transportable device, all the items needed to maintain resistance: a set of standard resistors, a controlled temperature bath, a low thermal emf scanner, and measurement data.
-
Product
DOUBLE FREQUENCY DOUBLE VOLTAGE TEST SET
-
International Biological Laboratories
This test set provides a continuously variable output voltage at double frequency to test the insulation between turns of coils, layer to layer, terminals of windings with either uniform or graded insulation and also between the windings and earth, with graded insulation of both Distribution and Power transformers.
-
Product
Radio Frequency (RF) And Microwave Products
-
Enable your 5G, aerospace, defense, test and measurement or industrial RF wireless applications with our portfolio of RF and microwave devices. These include high reliability RF diodes, Gallium Nitride (GaN) and Gallium Arsenide (GaAs) Monolithic Microwave Integrated Circuit (MMIC) amplifiers, frequency translation and power transistor devices, switches, attenuators, varactors, filters and more.
-
Product
800MM 31.5In Digital Level Bevel Gauge w/ LCD Backlight Screen, Level Bubbles IP54 Standards
DL411
-
Advance Plus Trading Co., Ltd.
Model Number: DL411 Key Specifications/Special Features: 800MM 31.5INCH Digital Level with level bubbles, 2 hand shanks, LCD bright backlight display, IP54 standards 1. 800mm 31.5inch level with 2 bubbles, 800*28*64mm(L*W*H), net weight: 700g;2. Resolution: 0.05°;3. Horizontal level measuring range: 0 to 360°;4. Accuracy: ±0.3°;5. Measures angle in degrees, IN/FT, mm/m, % slope or pitch;6. Audible tone at level, plump and setting angle;7. Automatic shut-off after 3 minutes;8. Backlight LCD;9. Self checking accuracy;10. Self calibration;11. Hold-function to freeze the measurement;12. Memory recall (9 measurements);13. 2pcs Handshanks design, easy to take and use;14. 2pcs high accuracy horizontal & vertical bubbles, clearly to check;15. Operated by DC 3V (2*LR03 AAA 1.5V batteries, not included); 16. IP54 waterproof & dusyproof industrial standard.
-
Product
Neodymium Low Frequency Transducers
-
High energy neodymium magnetic designs, complex cooling systems and new technologies for high-power handling, minimal distortion and low weight.
-
Product
Optical Frequency Combs
-
The Optical Frequency Comb technology is regarded as a breakthrough technology for measurements with highest accuracy. Lowest phase noise, stable supercontinuum, and turn-key operation make the Menlo Optical Frequency Comb solutions unique in accuracy and reliability. According to our principles: The best Optical Frequency Comb for any application.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T36-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.17 (33.20) - 4.50 (128.00) Battery Probe
CP-2TB-8
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 88Full Travel (mm): 2.25Recommended Travel (mil): 78.7Recommended Travel (mm): 2.00Overall Length (mil): 315Overall Length (mm): 8.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Test Workflow Standard
test
Test Workflow equips engineers with application-specific tools so that they can choose the right one for the job—from graphical programing environments to no-code and interactive software applications. Engineers can use Test Workflow software to perform quick ad-hoc tests, build an automated test system, automate data analysis and reporting, develop test sequences, and more.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1T
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
High Power Frequency Converter
BL+ Series
-
Behlman's BL-PLUS Series High Power AC Source/ Frequency Converter provide the performance of a linear with all the benefits of a switching amplifier. Instead of relying on large, noisy motor generators for AC power, today's testing facilities are switching to quiet, compact Behlman AC Power frequency converters.
-
Product
Frequency Divider
Trig-TekTM 313A
-
Divide high frequency to a lower frequency with an exact integer division with 1-digit divisor increments from 1 to 9999
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1HF-4
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1Z1-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Solution Standard Reference Materials
-
NCS Testing Technology Co., Ltd.
Solution Standard Reference Materials by NCS
-
Product
Dytronic Primary Transfer Ultra Stable Standard
RD-22 Ultra
-
The RD-22 Dytronic Primary Transfer Ultra Stable Standard represents the state-of-the-art technology in a commercially available AC transfer reference. The Ultra Stable RD-22 is a variant of the RD-22 Primary Transfer Standard that has been optimized for 120/240 V @ 5A operation to provide optimum stability. In a stable test environment, repeatability for a 10-second test of ±0.6 µWh/VAh is attained at 120 V and 240 V at 5A inputs with a 95% confidence interval. A typical experimental 2 repeatability of less than ±0.25 µWh/VAh is achieved. In a stable test environment, a reproducibility of ±2 µWh/VAh over a five-day interval is attained at 120 V and 240 V at 5A inputs with 95% confidence interval.
-
Product
High Frequency Surge Testers
-
The 50KV Digital P J High Frequency Surge Tester is the most powerful tester in a class of its own. No other 50KV Surge Tester can pulse/resonate 60 pulses per second at a risetime of 100 nano seconds.This powerhouse is loaded with the TDS3012B Digital Phosphor colored oscilloscope with a built-in floppy disk drive.
-
Product
Standard 1.00 (28.00) - 1.80 (51.00) General Purpose Probe
P2662BG-1R1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
Standard 3.06 (86.70) - 4.00 (113.40) RF Probe For SMA Connectors
CSP-30ES-013
High Frequency Probe
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Return Loss @ -20dB (GHz): 22.00Test Center (mil): 328Test Center (mm): 8.33Recommended Travel (mil): 100Recommended Travel (mm): 2.54Full Travel (mil): 200Full Travel (mm): 5.08Overall Length (mil): 1,033Overall Length (mm): 26.24Rec. Mounting Hole Size (mil): 297Rec. Mounting Hole Size (mm): 7.54
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Replaceable General Purpose Probe
MEP-30G
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53
-
Product
Erbium Fiber Frequency Comb
-
Detailed description of item: The AOSense frequency comb is a low noise, polarization maintaining (PM) device. Key features include a PM fiber architecture centered at 1550nm with turnkey modelocking; a free-running linewidth of the carrier-envelope offset frequency of <200 kHz; a temperature-insensitive all-fiber f-2f interferometer exhibiting fceo beatnotes with SNR > 45dB (300kHz RBW); and dual fast/slow cavity length actuators with a bandwidth of >300 kHz. The repetition rate of the comb is factory set and allows matching across multiple combs for dual comb applications. The optics package incorporates an optical heterodyne module designed for locking to the comb to an ITU-specified laser reference. The comb is capable of supporting an Allan deviation of < 5 x 10-18 at 1 second and ~10-20 after 105 seconds. Add-on features include all fiber extensions to visible wavelengths corresponding to several atomic transitions. An integrated comb electronics package is currently under development.
-
Product
Hydrogen Penetration Monitoring System
MS3112
-
The Hydrogen Penetration Monitoring System™ provides a method for directly measuring the rate of hydrogen migration through a vessel or pipe wall. This method actually measures the penetration current set up by the hydrogen as it moves through the steel. By sensing and recording this data directly from the pipe wall, this system offers valuable data which can only be indirectly inferred by other methods.
-
Product
Real Time MM-Wave Frequency Analyzers up to 180 GHz
-
When millimeter-wave applications came into many domains of human activity, a need for precise measurements of signal frequency spectrum has become critical. This need is quite understandable when, for example, it concerns to exploring extraterrestrial radio-sources or micro/mm-wave background emission in radio-astronomy, or measuring chemical composition of the atmosphere through the molecular emission of different its components, plasma diagnostics or many military applications.
-
Product
Conformance Calibration Standard Test Card for GS1-128 Symbol Verifiers
AI-CCS-128-E Rev B
-
This test card is ideal for testing of verifiers, scanners, and other GS1-128 barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3T
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Frequency Converters
-
CAES offers a full range of custom frequency converter solutions including narrowband, wideband and block upconverters and downconverters.
-
Product
Impedance Analyser Frequency Response Analyser
C60
-
The C60 investigates the opaque world of analog networks. The unit operates in two test modes. It can measure the frequency response of a two port system producing a gain/loss and phase graph. It can also measure the reactive response of a two terminal network producing an impedance/admittance and phase graph. Electronic, electrical, electro-acoustic and other networks can be tested with sine wave excitation and the results displayed on a PC.