An accurate current units of measure to facilitate comparison to and adjustment of instruments.
-
Product
Solid State Current Injector
J2111A
-
The current injector is one of the most versatile of the injector products. Coupled with the G5100A, or other equivalent function generator, it is capable of performing small signal load steps up to 40MHz, with very fast rising and falling edges. Using the G5100A, also allows the rise and fall times to be controlled, various waveforms or even arbitrary waveforms. This can be used to simulate the effects of many different types of loads, including high speed digital circuit loading, which is often largely dynamic.
-
Product
High Current Probes (Plug Connectors) HCE04FB52G10E081
1039767
-
The High Current Probes HCE04FB52G10E081 are designed to provide exceptional connectivity for demanding applications, featuring a basic contact probe design that ensures reliable performance under rigorous conditions. These probes can handle continuous currents of up to 40A, making them ideal for high-power applications. With a temperature tolerance ranging from -45°C to +200°C, these probes are suitable for various environmental settings, ensuring versatile use in different scenarios. The design integrates a robust construction with brass and high-grade steel materials, ensuring durability and longevity even in harsh conditions.
-
Product
Split Type AC Current Sensor
CTF-24
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*For AC current and power measurements.*Wide measuring range (AC 0.1~200A).*Compliant with RoHS drective.
-
Product
Calibration Lead - Precision Resistor Modules
40-975-037-02-1m
Cable Assembly
The cable assembly is specifically designed to connect to the 37-Pin D-Type calibration port located on the front panel of Pickering Interfaces Precision Programmable Resistor Modules 40-293 and 50-293 enabling calibration via an external DMM.
-
Product
Current Measurements of PWM or Inverter, AC/DC 25~500A, φ35mm
CTF-500DC
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 25~500A*Current measurements for PWM or inverter
-
Product
AC/DC Current Clamp Meter
CM600
-
Clamp opens up to 1 inch (25.4 mm). One rotary switch operation. Large 4 digit LCD display. AC/DC Voltage measurement up to 600 Volt. AC/DC current measurement up to 600 A.Relative measurement. One touch auto zero.
-
Product
High Current DC Transformerd
-
High Current DC Transformer provides very accurate DC current measurements up to 3000 A with output current that varies directly with the input current in three ranges. This direct current transformer is designed with an open window to pass a single cable, set of cables, or buss bar that carry the direct current to be measured.
-
Product
High Current Probes (Power Electronics) HCF73206B180G150
1008140
-
The HCF73206B180G150 High Current Probe is designed specifically for high current applications, making it an ideal choice for power electronics testing. This basic contact probe features exceptional performance capabilities with a continuous current rating of 20 Amperes and a typical contact resistance of just 10 mOhms. It operates effectively across a wide temperature range, from -45°C to +200°C, ensuring reliability in diverse environmental conditions. The probe's precision engineering guarantees accurate measurements, with a pointing accuracy of ±0.08 mm, which is critical in high-precision tasks.
-
Product
High Current Probes (Inverter Testing) HCB155D12MS62TYPK
1136614
-
The High Current Probes (Inverter Testing) HCB155D12MS62TYPK, with order code 1136614, are designed for precision measurements in demanding electrical environments. Capable of withstanding a temperature range from -45°C to +200°C, they are ideal for a variety of testing applications. When used for inverter testing, these probes demonstrate exceptional reliability due to their low typical contact resistance of just 0.25 mOhm, ensuring accurate measurement of currents up to 400 A continuously.
-
Product
High Current Probes (Battery Contacting) HCF34009S350L400S1
1020515
-
The High Current Probes (Battery Contacting) HCF34009S350L400S1 are designed for precision in electrical connections, featuring a robust Basic Contact Probe design. With a pitch of 4.00 mm (157 mil) and an operating temperature range from -45°C to +200°C, these probes are engineered for extreme conditions while ensuring reliable performance. The unique S1 designation highlights their advanced capabilities tailored for high-current applications, making them indispensable in various industries such as automotive and industrial automation.
-
Product
Leakage Current Testers
-
For general-use electrical devices Built-in non-medical use networks For rated currents of up to 20A For automatic testing on production lines, etc.
-
Product
High Current Probe HCB052A11MS15
1089466
-
The High Current Probe HCB052A11MS15 (item number 1089466) is designed for test and contacting tasks with high electrical currents. HCB052A11MS15 focuses on current capacity and low transition losses, as required in battery testing, formation and other e-mobility applications. In HCB052A11MS15, the compact assembly integrates the current path into a defined interface, where current capability, contact resistance and contact force are key design parameters. Electrical specifications for HCB052A11MS15 include 70 A continuous current and 3 mΩ typical contact resistance. For HCB052A11MS15, spring force is 1500 cN at a nominal travel of 4 mm.
-
Product
Current Sense Magnetics
-
Current sense magnetics are used as a low loss method for sensing AC current in a circuit and also provide electrical and safety isolation between the source of the current and the measurement circuit. The key parameters for a current sense transformer are the rms current rating (to ensure it does not overheat in the application) and the safety and voltage isolation (to ensure it conforms to the end-application requirements).
-
Product
Black Body Calibration Sources
-
Nagman Instruments & Electronics Pvt. Ltd
Black body calibration sources by Nagman are used to calibrate infrared temperature devices that are used to measure temperature. Infrared devices can measure extreme temperatures that are very high as well as very low. They allow to measure temperature from a safe distance from the device that is heated or cooled. Calibrating the infrared temperature devices at regular intervals is very important to ensure an accurate and error free measurement. Black body calibration sources allow for an accurate calibration of the temperature devices.
-
Product
AC Current Clamp Adapter
LAD-800
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
●Selectable CT ratio 10:1 and 100:1.●φ80mm CT window, possible to measure from leakage to big current up to 1000A.
-
Product
Open-Short-Load RF calibration kits
-
Open-Short-Load RF calibration kits from Fairview Microwave are available with Type N or 7/16 DIN connectors. Type N open-short-load RF calibration kits have male or female genders, 7/16 DIN open-short-load kits are male gender. Type N open-short-load (OSL) calibration kits for RF have a minimum frequency of 0 (DC) and a maximum frequency range between 4 GHz and 6 GHz. Type N open short load kits for calibration have a maximum power handling of between 1 Watt and 2 Watts.
-
Product
Pressure Calibration
-
We make pressure calibration easy! All you have to do is hand us over your gauge or meter! We’ll look after the rest, half inch, quarter inch, brass or steel fitting, we have the adapters to make it work.
-
Product
Frequency Extension Calibration Kits
FEK
-
Farran’s FEK-xx-0001 calibration kit provides accurate calibration of the Vector Network Analyzer (VNA). It is compatible with TRL and SOLT calibration techniques and allows for a full 12-term port calibration.
-
Product
High Current Probes (Power Electronics) HCF77317B400G300
1013056
-
The High Current Probes (Power electronics) HCF77317B400G300, identified by MPN 1013056, is a precision tool designed for efficient electrical contact in various power electronics applications. Its brass handle provides durability, ensuring reliable operation even under demanding conditions. This probe operates within a temperature range of -45°C to +200°C, making it suitable for a wide array of environments. Its design as a basic contact probe with a pitch of 3.50 mm enables excellent connectivity, critical for high-performance electronic testing and development.
-
Product
Network Analyzer N-Port Calibrated Measurements
S93551B
Network Analyzer
The S93551B adds a multiport analyzer mode that enables full N-port error correction and measurement capabilities using an external test set.
-
Product
AC / DC Current Probe, 2 MHz, 500 Arms
N2780B
Battery Probe
The N2780B current probe is an accurate and reliable solution for measuring AC and DC currents. Using a hybrid technology that includes a Hall effect sensor and an AC current transformer, the probe provides accurate measurement of DC or AC currents up to 500 Arms continuous.
-
Product
High Current Probes (Battery Contacting) HCF73216B100G300A
1165611
-
The High Current Probes (Battery Contacting) HCF73216B100G300A is designed for optimal performance in various high-current applications, operating efficiently within a temperature range of -45°C to +200°C. With a compact design, this basic contact probe features a pitch of 2.54 mm (100 mil), making it versatile for precise electronic connections. Constructed from high-quality materials, including beryllium copper for the plunger and brass for the barrel, it guarantees durability and reliability in demanding conditions. The probe's engineering ensures a typical contact resistance of just 10 mOhm, supporting continuous current capabilities of up to 20 A, facilitating seamless power transfer across applications.
-
Product
Current And Voltage Input Sensors
-
Current input sensors monitor current from inverters in solar panel and wind turbine applications and turn the current into voltage which can be measured with an analog input type data acquisition module for analysis. Voltage Input Attenuators can be used to measure high voltages. Voltage Attenuators are designed for used in high-voltage applications. The current can be converted into +/-10 Vpp attenuated signal, so that a general electronic measuring device is able to read the signals.
-
Product
Device Current Waveform Analyzer, 1 GSa/s, 14/16-bit, 2 Channel
CX3322A
Waveform Analyzer
The CX3322A is a 2-channel model for engineers and researchers who just need one or two current waveform measurements at one time. Using a single channel current sensor (CX1101A, CX1103A) and a passive prove interface (CX1151A) enables power measurements. The bandwidth and the memory depth per channel are option and can be selected from 50 MHz, 100 MHz and 200 MHz, and 16 Mpts, 64 Mpts and 256 Mpts, respectively. The number of channels is not upgradable, but upgrade products for both bandwidth and memory depth options are also available for customers who need more performance after purchasing the product. You could also minimize the initial investment for later upgrade with this affordable 2-channel model.
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Single 6-Channel, 4-Pole
42-514-102
Multiplexer Module
The 40-514-102 (PXI) and 42-514-102 (PXIe) are low density multiplexers in single 6-channel, 4-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
High Voltage, High Current Linear Amplifier
P100
-
The P100 is a general purpose linear amplifier having a fixed amplification of 10 times and capable of bipolar high voltage output of ±50V. Any functiongenerator or arbitrary waveform generatoror any othe signal source with amplitude up to ±10 V can be used as an input device.
-
Product
Horizontal Calibration Benches
-
a remarkable instrument for all measuring tasks that require extremely high accuracy.
-
Product
On-Site Calibration Services
-
Labsphere offers on-site spectral radiance calibration services for HELIOS and other uniform source systems.
-
Product
RTD & T/C Calibrators
-
Portable Handheld models capable of simulation & measurement of RTD & Thermocouple signals.
-
Product
High Current Probes (Power Electronics) HCF36011B130G080
1012191
-
The High Current Probes, model HCF36011B130G080, are designed specifically for power electronics applications, making them essential tools for engineers and technicians requiring reliable performance under demanding conditions. With a temperature range of -45°C to +200°C, these probes can handle a variety of operating environments, ensuring consistent functionality even in extreme temperatures. Their outstanding continuous current rating of 15A and minimal contact resistance of 15 mOhm further underline their capability to deliver precision measurements without significant loss of power.