Shielding
Protects against or confines electromagnetic or ionizing radiation.
See Also: Shielding Effectiveness
-
Product
Magnetic Field Cancelling System
MK-1
-
Single axis magnetic field cancelling system for MRI scanners and biomagnetic applications. This system is used when the magnetic field sensor cannot be placed within the shielded volume. For example, in MRI applications the sensor is usually installed outside of the shielding room because of the MRI scanner's high fringe field.
-
Product
Field Strength Meters
FIM-22 And FIM-41
-
The Models FIM-22 and FIM-41 are portable field strength meters designed to provide precise, direct measurements of electro-magnetic fields in the 200 kHz to 5.0 MHz spectrum. These units include a receiver, integral shielded loop antenna, precision attenuator, internal calibration source, and battery power supply. With calibration accuracy traceable to the National Institute of Standards and Technology, the FIM-22 and FIM-41 meet the most exacting requirements of government and industry. Their hinged covers, on the rugged drawn aluminum cases, contain a loop antenna. Opening the cover to a vertical position connects the antenna terminals to the receiver via maintenance-free gold-plated contacts. An interlock switch prevents inadvertent battery discharge when the cover is closed.
-
Product
VECTOR-GUN HANDHELD DIRECTION FINDING ANTENNA SYSTEM
HFDF
-
National RF's Type HFDF active directional antenna system consists of a high gain RF amplifier coupled to a tunable Faraday shielded loop antenna. Several loop antenna assemblies are available to provide coverage of frequencies in the HF and low VHF spectrum. Due to the nature of a Faraday shielded loop, the antenna exhibits a sharp null through the diametric center of the loop. This null is used to determine the direction of incoming radio signals or to locate electrical noise being radiated from some source. The internal high gain amplifier is used to compensate for the inherent inefficiency of the actual loop at the operating frequency. Overall, the system dynamic response is about +6 dB as compared to the dynamic response of a dipole. To aid in the direction finding process on strong signals, an internal 30 DB attenuator is provided. As the loop antenna presents a bi-directional response, tri-angulation may be required to eliminate the ambiguous signal direction. The line of site of the incoming signal is determined by listening for a signal null on the receiver or by watching the receiver’s S-meter.
-
Product
RF Flexible Cable Assemblies
-
Industry leader in manufacturing excellence, tailored performance, and rapid delivery of custom cable assemblies. The Flexible version, our Mini-Flex, has an FEP jacket, round braid and inner spiral shields and is available in 2 diameters, .105" &.165". The Semi-Rigid cables are available with a copper or aluminum jacket and available with a selection of different platings and 4 different diameters (.047", .085", .141" & .250"). The Conformable®, or hand formable (BJ - Braided Jacket), has a tin filled braid with a metal foil underlay and is also available in the same diameters as the Semi-Rigid type . All 3 types (Semi-Rigid, Conformable & Mini-Flex) are manufactured using the same type dielectric core and have virtually the same electrical performance. The decision of which cable to use should be primarily based upon your application.
-
Product
X2 GPIB Cable,Double-Shielded,Shielded Plug/Receptacles,1 m
763061-01
-
24-Pin Male/Female GPIB to 24-Pin Male/Female GPIB, Stackable, Double-Shielded GPIB Cable - The 24M/F-24M/F X2 Cable, sometimes referred to as an X2 cable, connects your system to GPIB devices or interfaces for instrument control. The 24M/F-24M/F X2 Cable has 24-pin IEEE 488 male and female connectors, and the cable is double shielded with shielded plug/receptacles. The 24M/F-24M/F X2 Cable is also offered in different lengths.
-
Product
PCI 32xSPST Shielded Reed Relay Card
50-125-021
-
The 50-110/115 range of PCI shielded switching cards are available in both Changeover (SPDT) and Normally Open (SPST & DPST) configurations. Connections are made via a front panel 200 pin female connector.
-
Product
100 Ohm Twinax Cables
PE-S330
-
PE-S330 part number from Pasternack is a PE-S330 twinax cable that is flexible. Pasternack PE-S330 flexible twinax cable is 100 Ohm and has a PE dielectric. Our PE-S330 twinax is constructed with a 0.33 jacket made of PVC. PE-S330 twinax has a shield count of 2 and the maximum frequency for this Pasternack cable is 400 MHz.
-
Product
Test adapter LRP-LR (Type D, 4 mm)
MA-LPL02D
-
Hachmann Innovative Elektronik
Our test adapter MA-LPL02D connects LR measuring devices to standardized LRP string parts and capacitive test points. An insulating tube with great dielectric strength shields the user from static energized test points without automatic earthing.
-
Product
93 Ohm Coax Cable
RG62A/U
-
RG62A/U part number from Pasternack is a RG62 coax cable that is flexible. Pasternack RG62 flexible coax cable is 93 Ohm and has a PE (AS) dielectric. Our RG62 coax is constructed with a 0.239 jacket made of PVC. RG62 coax has a shield count of 1, a RF shielding of 45 dB and the maximum frequency for this Pasternack cable is 1 GHz. RG62 coax cable has an attenuation at 1 GHz of 8.7 dB and a maximum power of 77 watts at 1 GHz.
-
Product
Board
Arduino Mega 2560 Rev3
-
The Arduino Mega 2560 is a microcontroller board based on the ATmega2560. It has 54 digital input/output pins (of which 15 can be used as PWM outputs), 16 analog inputs, 4 UARTs (hardware serial ports), a 16 MHz crystal oscillator, a USB connection, a power jack, an ICSP header, and a reset button. It contains everything needed to support the microcontroller; simply connect it to a computer with a USB cable or power it with a AC-to-DC adapter or battery to get started. The Mega 2560 board is compatible with most shields designed for the Uno and the former boards Duemilanove or Diecimila.
-
Product
Original VXI Module Shield Kits
11399x Series
-
* Clamshell design fits C-size modules with 96-pin connectors.* Single-slot kit fits all VXI-1 Revision 1.0 to Revision 3.0 chassis.* Side shields include connector shrouds for maximum shielding.* RFI limiting, air vent slots along top and bottom edges for good air circulation thru the module.* Extruded front panel is bend resistant.* Component side shield has an address switch opening and non-rectangular mounting hole pattern.* Complimentary layout support includes PCB design template and CAD layout files.* RECOMMENDED FOR LEGCY APPLICATIONS ONLY due to its non-rectangular hole pattern.
-
Product
3U CompactPCI® Single 64-bit PMC Slot Carrier Board
cPCI-8301
-
- PICMG® 2.0 32,64-bit/33,66 MHz cPCI bus- Supports one single-size 32,64-bit/33,66 MHz PMC site in 4HP width- Universal V(I/O) decided by backplane- Comprehensive EMC shielding
-
Product
Shield Level / Pathloss Equipment
SG1000B/PR1000A
-
The SG1000 Signal Generator and PR1000A Preamplifier have been designed to simplify the measurement of shielding integrity in a shielded enclosure. When coupled with a high stability spectrum analyzer and an appropriate selection of test antennas, the SG1000/PR1000A combination can measure shielding effectiveness at all of the NSA 94-106 (supersedes NSA 65-6) defined test frequencies from 1 kHz to 10 GHz.The PR1000A amplifies the received signal from the test antenna and overcomes the high noise figure of the companion test receiver or spectrum analyzer. The PR1000A will ensure that the system noise figure will be less than 4.5 dB at all test frequencies from 1 kHz to 10 GHz. When used with a spectrum analyzer measurement bandwidth of 100 Hz, the system exhibits a sensitivity of -150 dBm at the test antenna output.To overcome high cable loss between the test antenna and the PR1000A assembly at 10 GHz, a remote low noise pre-amplifier (Praxsym PN 310-010091-001) is mounted directly onto the 10 GHz antenna.
-
Product
DCDC
GA Series
-
The GA series is an economically priced 15 watt DC/DC converter featuring ultra-wide input range, efficiencies to 85% and a continuous six-sided shielded case. Low ESRcapacitors are used both on the input and the output(s) to minimize the conductive noise. Other key features include: overvoltage protection, output trim adjustability, TTL and CMOS compatible remote on/off, short circuit protection and small size. The GA series measures only 1.6” x 2.0” x 0.40” and offers a power density of 11.7 watts/cu. in.
-
Product
ELT STALKER Vector-finder
VF-121
-
The Vector-Finder Types VF-121 and VF 121A are unique in the Vector-finder series of direction finding antennas. They incorporate a proven design, electro statically shielded loop sensing element with modern solid state low noise analog and digital technology to allow detection and location of aircraft band signals. Both the VF-121 and the VF 121A incorporate a unique digital modulator which allows the user to more easily home-in on unmodulated carriers. Such cases occur at airports when transmitter may be accidentally keyed on during aircraft overnight layovers. The VF-121 is specifically designed to be used on airport premises where signal strengths are high. To compensate for very strong signals, an integral attenuator is also incorporated to allow the user to operate the unit close-in to aircraft. The VF-121A differs in that a high gain, low-noise preamplifier is utilized with the sensing element in order to hunt signals that may be weak or at a distance. The unit is ideally suited for the location of ELT transmitters in the field. Both units are tunable over the 118 MHz to 130 MHz aircraft frequencies and interface directly to the user’s aircraft band receiver or transceiver via the antenna jack. With the antenna system connected to the receiver, the user will hear the desired signal. If the signal is unmodulated, the digital modulator will generate a tone on the carrier. When the handheld unit is rotated about, an audible null on the received signal or the generated tone will be heard. This null aligns with the axis of the equipment case and represents the direction of the received signal. This direction may be read from the black dial compass mounted on the top of the enclosure. As the response is bi-directional, triangulation may be used to determine the true bearing when the true direction is not known.
-
Product
68-Pin SCSI-II Female to 68-Pin SCSI-II Female, D-Type Shielded, 1m, Multifunction Cable
185262-01
-
68-Pin SCSI-II Female to 68-Pin SCSI-II Female, D-Type Shielded Multifunction Cable - The SH68-68-S connects compatible multifunction I/O devices to accessories or cables with SCSI-II connectors. 1m.
-
Product
MARATON Hazardous HE
-
MARATON is a family of MAgnetic field and RAdiation TOleraNt power supplies developed for CERN LHC. MARATON HHE is the 12 channel version for use in a hazardous hostile environment. Magnetic field tolerance is achieved by water cooling (up to 300G) and shielded components (up to 1200G). For radiation hardness (<30Gy) a quasi-redundant principle of power conversion is combined with special components. Further radiation sensible components are placed at remote locations.
-
Product
Blank Module, Receiver/ITA, 1 Module Position, 90 Series Modules
510104118
-
Blank modules are for unused module slots. The blank shielding module fills a module slot and shields signals between the modules. Blank modules fit in either ITA or receiver positions.
-
Product
MAX31856 Thermocouple Sensor Arduino Shield
SEN-30007-K
-
Quad channel thermocouple Arduino shield based on the MAX31856 universal digital thermocouple interface IC. This is an exciting update of the MAX31855, with improvements in resolution (19 vs 14 bits), on-board temperature reference (6 vs 4 bits), and compensation (fully compensated vs nonlinear correction required). The MAX31856 is interfaced via 4-wire SPI with options for interrupt triggering. An LDO and a high-speed level shifter are included on ALL device pins to allow interfacing with to any Arduino - both 3.3V and 5.0V variants - without sacrificing device performance in any operating condition.
-
Product
Relay Buddy Adapter Set
190-4
-
*Expands the testing capability of your Relay Buddy! *3 pack of adapters allows testing of shielded relays, same relays tested by #190 Relay Buddy *Relay adapter plugs into Relay Buddy first *Shielded relay then plugs into the top of the adapter
-
Product
Arduino Shields
-
Arduino shields are modular circuit boards that piggyback onto your Arduino to instill it with extra functionality.
-
Product
1.5-m, 78-pin Dsub Cable
Y1137A
-
The Y1137A is a M/F twisted-pair cable with outer shield. The 300-V cable provides a direct connection for the Keysight multifunction switch / measure mainframe and modules. Some modules require two cables.
-
Product
BNC-2110, 68-Pin SCSI to Female BNC and Spring Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block
777643-01
-
68-Pin SCSI to Female BNC and Spring Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block - The BNC-2110 can be used with various NI multifunction I/O and analog output devices. The BNC-2110 simplifies the connection of analog signals, some digital signals, and two … user-defined connections to the data acquisition device while maintaining the integrity of your measurements with a shielded enclosure. It includes a DIN Rail and a desktop mount option.
-
Product
Coax, Patchcord, ITA, 36", Micro Coax, RG316DS Tan (Double Shield), Single-Ended
7-361117000-036
-
Coax, Patchcord, ITA, 36", Micro Coax, RG316DS Tan (Double Shield), Single-Ended.
-
Product
MAX31856 Thermocouple Sensor Arduino Shield
SEN-30007-ST
-
Quad channel thermocouple Arduino shield based on the MAX31856 universal digital thermocouple interface IC. This is an exciting update of the MAX31855, with improvements in resolution (19 vs 14 bits), on-board temperature reference (6 vs 4 bits), and compensation (fully compensated vs nonlinear correction required). The MAX31856 is interfaced via 4-wire SPI with options for interrupt triggering. An LDO and a high-speed level shifter are included on ALL device pins to allow interfacing with to any Arduino - both 3.3V and 5.0V variants - without sacrificing device performance in any operating condition.
-
Product
Shield
Arduino 4 Relays Shield
-
The Arduino 4 Relays Shield is a solution for driving high power loads that cannot be controlled by Arduino's digital IOs, due to the current and voltage limits of the controller. The Shield features four relays, each relay provides 2 pole changeover contacts (NO and NC); in order to increase the current limit of each output the 2 changeover contacts have been put in parallel. Four LEDs indicate the on/off state of each relay.
-
Product
Zero Chamber
-
The Mu-Metall-Chamber shields hall probes against the earth's field and therefore allows "zeroing" protected from external effects.
-
Product
Antennas
-
The PLA-R and PLA-T are active, battery powered receive and transmit loop antennas for the frequency range 9 kHz - 30 MHz intended for radiated emission testing (PLA-R) and site validation: Normalized site Attenuation, Shielding Effectiveness (PLA-SET consisting of PLA-R and PLA-T)





























