IEPE Microphones
measure acoustic frequency, time and noise levels.
-
Product
2 Channel Microphone Power Supply and Conditioning Amplifier
SoundConnect 2 mic power supply
-
SoundConnect 2 is a rugged 2-channel USB controlled microphone power supply and conditioning amplifier.
-
Product
PCB TA01, 5 mV/g, IEPE, Accelerometer, Triaxial Vibration Sensor
780990-01
-
5 mV/g, IEPE, Accelerometer, Triaxial Vibration Sensor - The PCB TA01 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB TA01 features a sensitivity range of 5 mV/g.
-
Product
Microphone Preamplifier
426A30
-
1/2-inch preamplifier with 7-pin LEMO connector (for externally polarized microphones)
-
Product
256kS/s/ch, 24-Bit, 4-Ch IDAQ Module For IEPE Sound And Vibration
iDAQ-801
Sound and Vibration
Hot-swappable in iDAQ system4-ch simultaneous sampling up to 256kS/s24-bit resolutionDirect IEPE supplyAnti-aliasing filter equippedHigh gain up to ±187.5mV input range
-
Product
complete 1/2 inch Type 1 Measurement Microphone System
PS9200KIT
-
A complete 1/2 inch Type 1 measurement microphone system. Available in 1 Inch and 1/4 Inch versions. The heart of the KIT is the 1/2 inch Type 1 measurement microphone. A selection of 4 different 1/2 inch capsules is offered. These include models with frequency responses to 40 kHz, noise floors of 12 dBA in both free field and pressure versions. Microphone sensitivities range from 12 to 50 mV/Pa.
-
Product
Digital USB Sensor Interface AC,DC, IEPE
ROGADAQ2
-
The RogaDAQ2 USB DAQ is developed for highly accurate measurements in the T&M and also for NVH measurements. This USB Front End is optimized for noise and vibration measurements with 2 channel IEPE (ICP®) sensor supply.
-
Product
Measurement Microphone System
MK224SYS
-
The MK224SYS Type 1 measurement microphone system offers a cost effective option to acoustic measurements. Perfomance: 8 Hz to 18 kHz response, 50 mV/Pa sensitivity and a "A" weighted noise floor less than 14 dBA.
-
Product
Easy Connection Of IEPE Sensors To Voltage Input Measurement Devices
K- IEPE
-
Our K-IEPE module is designed to connect IEPE sensors to a voltage measurement device that normally cannot support IEPE sensors. The powered K-IEPE module simply enables IEPE sensors to be connected via the BNC terminals and will output the signal voltages to an analog measurement device.
-
Product
Microphone Calibration Workstation
9350C
-
The Precision Acoustic Calibration Workstation Model 9350C is an accurate, turnkey, automated PC-based system that features cost-effective calibration of ¼", ½" and 1" microphone cartridges (open-circuit sensitivity), microphone cartridges with preamplifiers (closed-circuit sensitivity) and microphone Frequency Response Function.
-
Product
For accurate testing of headphones, microphones telephones and loudspeakers
Artificial Mouths, Ears, and Couplers
-
Listen supplies artificial mouths, ears and ear couplers from Brüel and Kjær, GRAS and more.
-
Product
Microphones
-
All these measurement microphones have a XLR connector and require a phantom power. They can be connected to specially equipped soundcards or pre-amplifiers, only.
-
Product
Phantom Powered Measurement Microphone System
7052PH
-
The 7052PH Type 1.5TM phantom powered measurement microphone system offers a cost effective solution to acoustic measurements from phantom powered sources. Type 1.5TM - a superior Type 2. Frequency Response: <3 Hz to > 20kHz typ.(capsule). Sensitivity: 22 mV/Pa (-33 dBV/Pa)typ. Dynamic Range (capsule) 1% THD: <20dBA-150dBSPL (Capsule).
-
Product
Precision Condenser Microphone
377B11
-
Performance:Nominal Microphone Diameter:1/2 CharacteristicPressureOpen Circuit Sensitivity: 50 mV/Pa50 mV/PaInherent Noise<15 dB(A) re 20 Pa<15 dB(A) re 20 Pa Dynamic Range (3% Distortion Limit)>143 dB re 20 Pa>143 dB re 20 Pa EnvironmentalTemperature Range (Operating)-40 to +248 F-40 to +120 C Temperature Coefficient of Sensitivity (+14 to +122F (-10 to +50C))0.005 dB/F0.009 dB/C
-
Product
ICP Electret Surface Microphone
130B40
-
Low-profile surface pressure microphone and preamp, prepolarized
-
Product
PCB IMID01, 100 mV/g, IEPE, 2-Pin, Accelerometer, Industrial Vibration Sensor
784175-01
-
The PCB IMID01 is an industrial Vibration Sensor designed for permanent installations. This sensor helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. The PCB IMID01 features a sensitivity range of 100 mV/g and uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The sensor supports the IMI Industrial Accelerometer Cable as well as the MIL2M-Breakout Cable.
-
Product
Measurement Microphone
UMM-6 USB
-
Precision condenser microphone for critical measurement and recording applicationsConnects to your PC or Mac via USB portTrue omnidirectional pattern with calibrated flat frequency responseRugged construction with high-quality componentsCompact design; includes sturdy carrying case with foam insertCompatible with most industry-standard measurement software
-
Product
SparkFun Analog MEMS Microphone Breakout
ICS-40180
-
The SparkFun Analog MEMS Microphone Breakout makes it easy to work with the InvenSense ICS-40180 analog microphone. This board features an OpAmp to bring the output of the microphone to a usable level, allowing you to plug directly into an ADC on a microcontroller or something like the SparkFun Spectrum Shield.
-
Product
Microphone Pre-Amp Audio Interfaces
-
Analog Devices mic pre-amp audio interfaces provide a high fidelity, high performance solution for audio products. Specifications for this family include ultralow 1.5 dB noise figures, 140 dB gain range, and high gain capability. Operating in an extended industrial temperature range of –40°C to +85°C, this portfolio of mic pre-amp audio interfaces supports many applications, including precision instrumentation, active filters, low noise amplifier front ends, surveillance systems, computerized voice recognition, and a variety of other industrial and consumer products. As the first choice for serious audio engineers, Analog Devices mic pre-amp audio interfaces can give your applications the performance needed to meet the most demanding specifications.
-
Product
Measurement Microphones
SCM
-
The SCM measurement microphone is a robust, free- field microphone designed for the rigorous environment of a production line without compromising the accuracy, precision, and stability required for R&D.
-
Product
Omni Measuring Microphone
PVR™ 2
-
Omni-directional microphone for free-field measurement. With a highly reliable circuit and a 1/4" pre-polarized condenser capsule, it boasts high stability, low distortion and low noise in performance. Its excellent flat frequency response makes it ideal for sonic analysis systems and recording.
-
Product
PCB High Sensitivity, 100mV/g, ICP® (IEPE) Accelerometer
784170-01
-
The PCB HSTA15 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB HSTA15 features a sensitivity range of 10 mV/g and requires a 4-socket plug-to-3 BNC plug cable.
-
Product
Measurement Microphone System
7052SYS
-
The 7052SYS Type 1.5TM measurement microphone system offers a cost effective option to acoustic measurements. Perfomance: 4 Hz to >20 kHz response, 20 mV/Pa sensitivity and a "A" weighted noise floor less than 20 dBA.
-
Product
ICP Microphone System
378A14
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
Single Channel Microphone Power Supply
SoundConnect Microphone Power Supply
-
SoundConnect is a cost-effective, single-channel microphone power supply for audio test applications.
-
Product
PCB High Sensitivity, 100mV/g, ICP® (IEPE) Accelerometer
780989-01
-
The PCB HSTC33 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB HSTC33 features a sensitivity range of 100 mV/g and requires a low-noise coaxial cable.
-
Product
Specialty Test And Measurement Microphones
-
When acoustic measurements need to be made in demanding environments and applications, a variety of PCB® specialty microphones are available.
-
Product
Measurement Microphone Cartridges
-
G.R.A.S. Sound & Vibration A/S
Measurement microphones are available in many types covering various frequency ranges, dynamic ranges and application situations. Selecting a microphone involves a number of choices, which can be summarized as:
-
Product
IEPE Triaxial High Sensitivity Accelerometer 10V/g
HDBV-1000
-
HDBV-1000 is a tri-axial accelerometer for the measurement of human exposure to whole-body vibrations, according to ISO 2631 and ISO 8041.
-
Product
IEPE Triaxial Accelerometer – 10 mV/g
HDP356A02
-
Triaxial accelerometer miniature for hand-arm measurement, ICP, 10mV/g, weight 4g, range 500 g pk
-
Product
Externally Polarized Precision Condenser Microphones & Preamplifiers
-
Externally polarized microphones set the initial standard for all acoustic test and measurement applications. They rely on a dedicated 200V power supply and specialized cables with 7-pin LEMO® connectors. Their straightforward design supports a wide product range. Often chosen as replacements for existing models or when prepolarized alternatives are unavailable.





























