Fixed Attenuators
Fix the degree of attenuation.
-
Product
System Monitor 3 Gen (SysMon) Fix Mounted
041-039
-
The SysMon 3 Gen is a platform-independent system monitoring unit which monitors- and, if necessary, controls - the internal parameters of a System Platform such as voltages, temperatures, digital inputs and fan speeds.
-
Product
Variable Fiber Optic Attenuator
-
Variable fiber optic attenuator could help simulate distance or actual attenuation in the fiber optic testing work by inserting a calibrated attenuation into the link. By using the variable fiber optic attenuator, technicians could verify the power margin received by testing the fiber optic link power budget. Variable fiber attenuator can help user vary the light power injected from a light source into the optical fiber. Important parameter of variable fiber attenuator include its insertion loss, reflection loss and attenuation range.
-
Product
Power/Voltage Rail Probe. 4 GHz Bandwidth, 1.2x Attenuation, +/-30V Offset, +/-800mV
RP4030
-
The Teledyne LeCroy RP4030 Power Rail Probe meets the specific requirements of those who need to acquire a low-voltage DC signal as part of a:-Comprehensive power integrity, digital power management IC (PMIC), voltage regulator module (VMR), point-of-load (POL) switching regulator, or low-dropout regulator testing- Complete embedded power management system that includes PMICs, VRMs, POLs, and LDOsThe RP4030 will faithfully acquire a low-impedance, low-voltage DC power/voltage rail signal without unduly loading the device under test (DUT), while providing high offset to allow DC power/voltage rail signal display on an oscilloscope with high gain.
-
Product
Fixed Mounting Panel, i1, 2U, 8 Positions
310113517
Mounting Panel
The 2U Fixed Mounting Frame has 8 horizontal positions. i1 cover plate sold separately (310 113 546).
-
Product
Manual Attenuator (Waveguide)
-
RF Lambda’s manual waveguide attenuators are used to control signal levels using a manual control knob. These are commonly used in test setups or systems where an operator is present and there is a need to change signal levels manually.
-
Product
USB/Ethernet Control Step Attenuator
-
RF Lambda’s USB / ethernet control step attenuators utilize the same RF core as our standard digital attenuators only they incorporate a USB / ethernet controller to allow users to easily setup the control from any PC or network.
-
Product
CP400X, 400 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784254-01
High Current Probe
The CP400X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 2 meters in length. The CP400X attaches to BNC connections on both the signal input and instrument sides.
-
Product
HVFO10X +/-40V (40x Attenuation) Universal Tip Accessory
HVFO100-40X-TIP-U
-
HVFO10X +/-40V (40x Attenuation) Universal Tip Accessory.
-
Product
Fixed Wavelength CW Laser Source (FP) - PXI
Laser 1100 Series
Laser Source
The Laser-1102 is a Continuous Wave (CW) laser source offering high power 850 nm output into multimode fiber with stable output power operation.
-
Product
Bench Power Supply, Adjustable, Fixed, 3 Output, 0 V, 32 V, 0 A, 5 A
72-13610
-
*Triple channel linear DC power supply*Dual channel adjustable & one channel fixed*Constant current & constant voltage operation*Forced ventilation & temperature cooling system*LED digital tube display shows voltage and current simultaneously*Low ripple & low noise, output on/off control*Overload and reverse polarity protection*115VAC/230VAC (50Hz/60Hz) AC input voltage and 0.01% high regulation*12-month limited warranty *view Terms & Conditions for details
-
Product
Manual Attenuator (Coaxial)
-
RF Lambda’s manual coaxial attenuators are used to control signal levels using a manual control knob or buttons. These are highly reliable and commonly used in test setups where the operator needs access to tune RF signals without the need for any digital or voltage control.
-
Product
Fixed Gas Detectors
DG7 Series
-
Teledyne Gas & Flame Detection
All DGi-TT7 are constructed from a common housing and electronics with the detection properties being determined by the type of sensor (cartridge) used. A wide range of cells are available, these cells are intrisically safe protected, and may be replaced with the detector powered which minimises the system down time. The intelligent, microprocessor driven unit is fully configurable using a wireless hand-held terminal (TLU) or by using the hard wired HART option giving true flexibility to the installer and reduced service costs.Elements such as relay operation and alarm levels are all set via the TLU, a hazardous area approved hand-held unit. The unit may be interfaced directly with a wide range of panels, controllers and PLC’s etc. Its integral daylight readable alphanumeric display indicates local status and alarm level.
-
Product
33% Beam Splitter - BK7, fixed horizontal-bend mount
E1834E
-
The E1834E is a 33% beam splitter in a high performance horizontal mount that offer the high pointing stability for Keysight laser interferometer measurement system. The 8 flexure feet are designed for stable beam pointing.
-
Product
Attenuators & Loads
-
*High power handling 100W with a wide range of available attenuation values*Very low PIM <- 160 dBc with excellent return loss performance*Support for 7-16 or 4.3-10 connectors and optional 19 inch rack mount kit*Designed and produced to ISO 9001:2008 certification standards for reliability and quality
-
Product
Bench Power Supply, Single, Adjustable, Fixed, 3 Output, 0 V, 30 V, 0 A, 3 A
72-6628
-
The 72-6628 is a Triple Bench Power Supply with adjustable current control and galvanized steel case. The DC regulated power supply is a completely solid state, compact, well regulated, constant voltage power supply suitable for service field, hobby, laboratory and testing use. It provides three different voltages output for different. Overload and short-circuit protection, prevent the unit from overload and short circuit. When the unit is under the condition of overload or short circuit, the output current will be limited. Independent 5V, 12V easy snap-on output terminals to make it easy to use for TTL and CMOS circuit testing. The grounding of the output terminals is independent that the output can be connected in series to make a higher output voltage.
-
Product
Multispectral Fixed Camera for Perimeter Protection
FH-Series ID
-
The FLIR FH-Series ID are ruggedized, multispectral fixed cameras that integrate industry-leading thermal imaging with 4K visible imaging to provide reliable intruder-detection capabilities for perimeter security. Built-in convolutional neural network (CNN) analytics accurately detect and classify human and vehicle threats moving at high or low speeds, minimizing false alarms and daily operations costs. Custom scheduling enables security operators to set intrusion analytics to run on visible streams during the day and on thermal streams throughout the night, establishing optimized coverage for any lighting condition.
-
Product
NI-5191, 800 MHz, ±30 V, 10X Attenuation, Differential Active Oscilloscope Probe
781785-01
Oscilloscope
The NI-5191 is a differential, active voltage probe that offers 800 MHz of input bandwidth with a 10:1 attenuation ratio. You can use it with oscilloscopes that provide 50 Ω input impedance. You can power the probe using a Type-N barrel power connector from a USB port or using a 9 V alkaline battery.
-
Product
Low-Cost, Fixed Focus, An-alogue High Definition Camera
L3C-AHD
-
The Teledyne Bowtech L3C-AHD is a low cost, fixed focus, An-alogue High Definition Camera. The analogue HD signal will travel up to 250 metres on a Teledyne Bowtech coax or a high quality screened twisted pair (a small inline mould is required to be connected between the camera and the umbilical when a screened twisted pair is used). The video is viewed on an HD monitor with an HDMI connection after going through a small topside converter box.
-
Product
Fixed Mounting Frame, iCon, 1U, 2 Positions, Painted Gray
310113491
Mounting Panel
The iCon Fixed Mounting Frame has 2 horizontal positions. iCon cover plate sold separately (310 113 467).
-
Product
SA2500X, 2.5 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784257-01
Oscilloscope Probe
The SA2500X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
Product
Bench Power Supply, Single, Adjustable, Fixed, 3 Output, 0 V, 30 V, 0 A, 10 A
72-7660
-
Compact, regulated constant voltage power supply for service field, hobby and telecommunication equipment. It provides three different voltage output for different usage.
-
Product
Fixed Clamp-on Flowmeter
D118
-
Gentos Measurement & Control Co.
The D118 ultrasonic flowmeter is based on Tansit-time technology, which has ultra-high measurement accuracy. D118 uses an external clipped Transducer, which can collect flow data simply by clamping it on the outside of the pipe, and it will never come into contact with the fluid, and will not cause liquid pollution, pressure reduction, leakage, etc.
-
Product
(125×150×20mm) C-Band DWDM FGA Full Function Module Fixed Gain EDFA Module
FGA4400-FM05
-
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai FGA4400-FM05 series is a fixed gain Full Functional EDFA module which is specifically designed for C-Band DWDM optic transmission system, accord with various communication technology requirements of 44 channels DWDM system. It adopts nowadays excellent optical performance, advanced electronic control technology and complete software functionalities. Excellent total integration electronic transient control technology ensures amplifier to achieve the locking of optimal flat gain (OFG) in large dynamic input optical power range.
-
Product
Programmable Step Attenuator DC~50GHz, 0~115dB Att.
-
The programmable step attenuator achieves step attenuation over a wide frequency band. It features high attenuation accuracy, excellent repeatability, low insertion loss, and long service life. Its primary applications include controlling the amplitude of signals entering systems, regulating output signal power in systems, and adjusting impedance matching between signal sources and loads. It is widely used in various broadband spectrum analyzers, broadband vector network analyzers, broadband synthesized signal sources, noise figure test sets, and diverse microwave automatic test systems.
-
Product
Attenuators
-
OZ Optics offers a broad range of both variable and fixed attenuators having key competitive advantages. All of our attenuators operate over the two standard wavelength bands, the C-Band and the L-Band. This wide wavelength range makes these components ideal for DWDM applications. Our attenuators are wavelength insensitive, which means they operate with minimal changes in attenuation when used in either the C-Band or the L-Band and exhibit low return loss. In addition, all of our attenuators have a wide attenuation range, which means they operate at a wide range of power levels. This is important as increased power levels are being used in newer optical systems.
-
Product
HVFO10X +/-5V (5x Attenuation) Universal Tip Accessory
HVFO100-5X-TIP-U
-
HVFO10X +/-5V (5x Attenuation) Universal Tip Accessory.
-
Product
Source - 20 GHz Source with Amp Attenuator
RI8554A
-
Automated Instruments, Powerful Development Tools and Worldwide Support
-
Product
Digital Control Step Attenuator
-
Digital control attenuators with TTL parallel control offering fast switching speed and high attenuation accuracy
-
Product
Attenuators And Pulse Limiters
-
A bidirectional attenuator, i.e. the attenuation and power capability specification is valid for both directions. There is a large variety of applications for this attenuator: The measuring range of a spectrum analyzer can be increased. Any kind of meter can be protected against overload; it can be used to control the linearity of a meter reading. It can minimize measurement uncertainty caused by mismatched impedances. During an EMI receiver calibration an attenuator directly at the pulse generator output is inevitable.





























