Arc Fault
unintended electrical discharge.
-
Product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A
40-194A-002
Fault Insertion Unit
The 40-194A-002 is a 7-Channel Fault Insertion switch with two fault buses, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
PXI-8511, 1‑ or 2-Port, Low-Speed/Fault Tolerant PXI CAN Interface Module
780686-01
CAN Interface
1‑ or 2-Port, Low-Speed/Fault Tolerant PXI CAN Interface Module—The PXI‑8511 is a fault-tolerant Controller Area Network (CAN) interface for developing applications with the NI‑XNET driver. The PXI‑8511 excels in applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals, such as hardware‑in‑the‑loop simulation, rapid control prototyping, bus monitoring, automation control, and more. The NI‑XNET device-driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts, minimize message latency and freeing host processor time for processing complex models and applications.
-
Product
Medical Box PC Featuring The 12th/13th/14th Gen Intel® Core™ I3/i5/i7/i9 Processors, With Support For MXM-AXe Based On Intel® Arc™ GPU, And Thunderbolt™ 4 Port
MLB-3100 with Intel MXM GPU
Industrial Computer
- ADLINK MXM-AXe graphics module support (type A, up to 50W TDP based on power supply)- 12th/13th/14th Gen Intel® Core™ i3/i5/i7/i9, Celeron® processor- Dual SODIMM for up to 64GB DDR5 non-ECC memory (depending on CPU)- 1x HDMI 2.0, 5x DisplayPort (1 from CPU, 4 from MXM)- 1x M.2 E-key supporting 1630 or 2230 for Wi-Fi/Bluetooth module, 1x M.2 M-key supporting 2242 or 2280 for SATA/PCIe storage module, 1x M.2 M-key supporting 2242 or 2280 for NVMe & frame grabber- Reliable Molex 24V DC-in connector- 2x 2.5GbE Intel® I225-LM Ethernet Controller
-
Product
Digital Fault Recording
SHERLOG
-
Fault recorder systems with a power quality analyser for comprehensively monitoring and assessing low, medium and high voltage networks in power plants and transformer substations. The measuring devices of the SHERLOG range make very high-resolution recordings of all the disturbances which occur in power supply systems. The behaviour of protection and switchgear devices during these system disturbances is recorded at the same time.
-
Product
Visual Fault Locator VFL
X4007
-
X-4007 series visual fault locator is used for the measurement in single-mode or multi-mode fibers. It features a rugged design, a universal connector and an accurate measurement.
-
Product
Ground Fault Location
-
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of ground fault locator from basic to advanced model to fast detect, trace and pinpoint virtual grounding faults in DC systems when systems are LIVE (working online). Without injecting any signal to the DC system, they are safe to your existing system. With Kongter’s unique technique for signal tracing, these ground fault locators are much faster and more effective to find the earth fault in the field than its peers.
-
Product
Visual Fault Locator
-
Shanghai Baudcom Communication Device Co.,Ltd.
This Pen-type VFL is specially designed for field personnel who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in optical networks. It finds breakpoints, poor connections, bending or cracking in fiber optic cables
-
Product
PXI 1A Fault Insertion Switch 22-Channel
40-195-001
Relay
The 40-195 is a 22 Channel Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions on pairs of signals between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Relays in-line with the signal paths allow open circuit conditions to be simulated on either side or both sides of a signal pair. Relays between each channel pair enable adjacent signals to be shorted, and relays between signal paths and the "Fault" connection allow the application of external user applied fault conditions.
-
Product
PXI Fault Insertion Matrix Modules
-
All of our fault insertion matrices feature a breakout arrangement that allows faults to be attached to the sensor lines via the Y axis. This includes the breaking of a connection or the adding of a series defect – all of which can simulate connectivity problems in the system. The three pin breakout versions allow the connection to be swapped for a “bad” sensor simulation.
-
Product
Visual Fault Locators
MVFL Series
-
Shanghai Tarluz Telecom Tech Co., LTD
MVFL series Visual Fault Locators is meet the Class IIIA product, which is the easiest way to identify fibers from end to end and locate polished connector endfaces. Its red laser shines through most yellow-jacketed fibers to help you pinpoint breaks, bends, faulty connectors, splices and other causes of signal loss. The 1mW output power enable the MVFL has a reach of up to 5 km. MVFL seires VFL locates faults visually by creating a bright red glow at the exact location of the fault on single mode (SM) or multimode (MM) fibers. Due to its small size, lightweight and simple but proven design, the MVFL can accompany you anywhere In your pocket or belt pouch in harsh environment
-
Product
Pen-based Fault Locator
-
*Find the breakpoint, bending or cracking*Find the fault of OTDR dead zone*Identification of fiber from one end to other end*Universal adaptor*Testing distance up to 8km*Lightweight, red laser output, both SM and MM available
-
Product
PXI 1A Fault Insertion Switch 11-Channel
40-195-101
Relay
The 40-195 is a 22 Channel Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions on pairs of signals between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Relays in-line with the signal paths allow open circuit conditions to be simulated on either side or both sides of a signal pair. Relays between each channel pair enable adjacent signals to be shorted, and relays between signal paths and the "Fault" connection allow the application of external user applied fault conditions.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A
40-194A-001
Fault Insertion Unit
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
Line Mounted Detector of PtG and PtP Faults in Line Networks
LineTroll 110EμR
-
The indicator is powered by replaceable long-life lithium batteries which have a life expectancy of 10-15 years. It provides a 360 degree visibility for indication both for transient faults and permanent faults.
-
Product
Detection of PtG and PtP Faults on Multi and Single Core Cables
CableTroll 2350
-
CableTroll 2350 is an indicator for detection of PtG and PtP faults on multi and single core cables. The unit uses standard type current transformers. (40:1, 60:1 or 3x500:1)
-
Product
Mobile Cable Fault Location System
BAUR Syscompact 4000
-
Fault location with Syscompact 4000. The Syscompact 4000 is a compact, fully enclosed fault location system for pre-location and pinpointing of high-resistive, low-resistive and intermittent faults on low- and medium-voltage cables. Easy operation and the use of latest fault location methods enable fast and safe fault location.* Location of low-resistive, high-resistive and intermittent cable faults* Efficient cable fault pre-location methods* Pinpointing according to the noise location method or acoustic propagation time measurement* (with Universal Locator and ground microphone)* Sheath fault location according to the step voltage method (with Universal Locator and two measurement probes)* Easy to handle
-
Product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 8 Channel
40-200-008
CAN Interface
This PXI Fault Insertion module is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This module supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses. Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signalling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
DC Ground Fault Locators
-
We currently offer one highly capable DC ground fault locator for sale to the United States, Canada and Globally. This fault locator is highly reliable and highly capable of locating any ground fault in a variety of settings. This one piece of ground fault locator equipment is all you will ever need to find any fault, in any location, in any system. With advanced computations and fuzzy logic it can very accurately display the insulation level of the tested circuit. We offer the best and only ground fault locator you will ever need. To learn more about his product please click below where you will also be provided key features and the ground fault locator specifications.
-
Product
Fault Locating
-
Schweitzer Engineering Laboratories, Inc.
The built-in fault-locating methods in SEL devices allow you to quickly identify faults, dispatch crews for repairs, and restore service faster. Traveling-wave fault-locating technology calculates the locations of temporary and permanent faults by measuring the arrival times of the naturally occurring traveling waves caused by a transmission line fault. Accurately detecting these waves requires ultra-high-resolution monitoring, and locating is accurate to within one tower span (±300 m). Impedance-based fault-locating technology calculates fault locations by detecting changes in line impedance as a result of a fault. Impedance-based locating is reliable and accurate to about 2 percent of a line’s total length.
-
Product
Dual Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-102
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
Visible Fault Locator
FiberLink 6656
-
Fiberlink 6656 Visible Fault Locator is a light-weight, hand-held tool used to quickly troubleshoot faults in the continuity of both single-mode and multimode fibers, especially at fiber launch points or in OTDR dead zones.




















