Infrared Calibrators
controlled sources of thermal radiation, used to calibrate infrared radiation devices.
-
product
Automated Calibration
ORION
ORION automates the process of characterization and calibration of engines. It facilitates the calibration process by taking control of both the ECU calibration system and the test cell control system to run experiments as part of an automated calibration process. With connectivity to IAV’s EasyDOE, Mathworks’ MBC Toolbox and other DOE tools, ORION provides an extremely powerful environment for mapping an engine and generating the Engine Management System calibration tables. The modular design means the product can be configured to a users’ specific requirements and work practices, rather than having to adhere to rigid methodologies dictated by prescriptive software.
-
product
Phasor Measurement Unit Calibration System
6135A/PMUCAL
The 6135A/PMUCAL system is the only fully automated and traceable PMU calibration system available today. It fully complies to the IEEE C37.118.1™-2011 and section 7 of IEEE C37.242:2013 standards for PMU operation and verification.
-
product
Calibration And Verification Instruments
The system of automatic calibration and verification consists of a computer of the operator's workplace and a control controller with a calibrator connected to it and a verified device. The device under test can have 4 to 16 working channels with a complicated circuit for connecting different types of signals: voltage, current, thermocouples, thermoresistance. The system allows a change in the set of operating ranges during calibration and calibration. The software development system used the LabVIEW development environment with the Real-Time module.
-
product
Portable Vibration Calibrator
AT-2040
With AT-2040 you will find the features required for your application without having to install cumbersome and expensive addons. AT-2040 features a full-automatic sensitivity test mode, sensor simulation, power supply output for sensors that require voltage such as the 7310 and 991V aviation sensors, a built-in sensor charge amplifier for both single-ended and differential charge accelerometers, and a custom sensor input that can be configured to fit most accelerometers with a one to one cable.
-
product
Humidity Calibration
Trescal provides full Humidity Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Humidity Calibration services can be delivered at your site or at our lab. Accreditations for our humidity calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
product
Robot Calibration
Achieve improved absolute robot positioning accuracy via dynamic robot calibration using API’s Laser Tracker and Active Target a self-orienting motorized 360° rotation SMR.
-
product
Infrared Thermometer
384
8:1 distance to spot ratio. Emissivity : Pre-Set 0.95. Functions : Display data hold, Backlight
-
product
Monitor Calibrator
hueyPRO
It's all about the color. Color in your photos, color in your designs, color online and more importantly, color on your display. World's first built-in ambient light sensor enables consistency never seen before in any lighting condition.
-
product
Calibration Services
For over 25 years, OAI (Optical Associate Inc.), is the leader in NIST traceable calibration of instruments for measuring Ultra Violet (UV) light. Originally designed to meet the demanding needs of the semiconductor wafer fabrication industry, OAI developed the most repeatable NIST traceable calibration in the industry.
-
product
Portable Analyzer and Calibrator
ECD’s portable analyzer and calibrator product lines are a simple convenient way to obtain fast, accurate pH and ORP measurements. They provide a milliVolt output signal for fast field analysis of samples, calibration verification, or trouble-shooting of installed sensors.
-
product
Handheld Calibrators
These handheld calibrators are perfect for calibrating thermocouples and RTD's in cases where the sensors are fixed or need to be calibrated on the spot. Locations such as factory floor or in the lab.
-
product
4-in-1 OSLT Calibration Kit, DC to 40 GHz, 2.92 mm (m)
CK562A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
Digital Infrared Thermometer
IR-710
Shenzhen Calibeur Industries Co., Ltd..
'- Non-Contact Infrared Thermometer With Laser Targeting '- Range: -38° C to +520° C/-36.4° F to +968° F'- Accuracy : < 0°C: ±3% or ± 3°C ≥0°C: ±2% or ±2°C'- Distance spot ratio (D:S) : 8:1'- ℃/℉ exchange,'- Size: 180x80x40mm'- Weight: 120g'- Power: AAA1.5V 2pcs (not included)
-
product
Reference Temperature Calibrator
JOFRA™ RTC-187
AMETEK Sensors, Test & Calibration
RTC-187 provides high-quality temperature measurement from -45 to 180°C. The 180°C is a 25° expansion over the range of the RTC-157, and it’s now the hottest temperature available for a calibrator that also supplies cold temperatures.
-
product
Infrared Camera for Methane and VOC Detection
FLIR GF300
The FLIR GF300 detects methane, other hydrocarbon, and volatile organic compounds resulting from the production, transportation, and use of oil and natural gas. This camera can scan large areas and visualize potential gas leaks in real-time, so you can check thousands of components over the course of one survey. Designed with the user in mind, the GF300 is lightweight, offers both a viewfinder and LCD monitor, and has direct access to controls.
-
product
Calibration Lead - Precision Resistor Modules
40-975-037-1m
The cable assembly is specifically designed to connect to the 37-Pin D-Type calibration port located on the front panel of Pickering Interfaces Precision Programmable Resistor Modules 40-297 and 50-297 enabling calibration via an external DMM.
-
product
Calibration Kit
N912
*N912 Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.
-
product
Calibration Baths
Fluke Calibration temperature baths provide optimal temperature environments for “secondary” or “comparison” temperature calibrations. They offer unsurpassed stability and uniformity, a large working volume, and flexibility for performing thermometer calibration on calibrating a variety of temperature sensors. A world-class temperature controller and 30+ years of experience make these the choice of National Metrology Institutes and calibration laboratories worldwide. Fluke Calibration temperature baths include: compact temperature baths; deep-well temperature baths; standard calibration baths; resistor maintenance baths; ice-point baths; bath / temperature controllers.
-
product
Calibration / AVP Service
Comware Technical Services, Inc.
Regular calibrations / AVPs will help ensure the measurement integrity of your system. We supply the calibration equipment or you can provide us with your own in-house equipment.
-
product
Sound Level Calibrators
PeakTech Prüf- und Messtechnik GmbH
For sound level measurements in extreme conditions, at high altitudes or high demands on the accuracy of the measurement results, sound level meters should be checked prior to the measurement with a sound level calibrator. Also for calibration and verification of microphones in audio technology, you need a sound level calibrator, which is designed to produce several sound pressure levels at a fixed frequency characteristic. This calibrator has two switchable calibration steps.
-
product
Multi-Cal Pressure Calibrator
MC
Series MC Portable Multi-Cal Pressure Calibrator performs a wide variety of simple and complex pressure based measurement, test, and calibration operations. Modular sensor design allows user to select pressure measurement range for application flexibility.
-
product
Automatic Cleaning and Calibration
Knick Elektronische Messgeräte GmbH & Co. KG.
Fully automatic process monitoring in combination with the analysis measuring system Protos and the retractable housings SensoGate or Ceramat. Highly accurate measurements even under difficult process conditions such as high pressure, high temperatures and high levels of impurities.
-
product
4-in-1 OSLT Calibration Kit, DC to 70 GHz, Type-1.85 mm (m)
CK058M
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
Data-based Modeling and Calibration
ASCMO
ETAS ASCMO is the easy-to-use-solution for advanced model-based calibration and data-based modeling in significantly less time. ETAS ASCMO enables the fast and efficient development of accurate data-based models. Once created, these high-accuracy models can be used to optimize parameters of real systems such as engine ECUs or plant models in different simulation environments (e.g. Simulink or HiL-Systems). Both, steady state and dynamic/transient system behaviors can be captured.
-
product
Infrared Thermometer
Shenzhen UYIGAO Electronic Technology Co., Ltd
Thermometer which infers temperature from a portion of the thermal radiation sometimes called blackbody radiation emitted by the object being measured.
-
product
Power and Energy Automated Calibration System
RS-933
The RS-933 Syntron Power and Energy Automated Calibration System calibrates a range of test equipment including; Energy Reference Standards, Digital Multimeters, Phase meters, Energy meters, Power meters, Revenue meters, Amp meters, Panel meters & Power Quality meters.
-
product
Pressure Calibrators
We offer pressure calibrators as portable and as workshop models. Pressure measurement is performed with internal and/or external pressure modules for better flexibility. Pressure measurement ranges go from vacuum up to 1000 bar (14,500 Psi). Both gauge (vacuum and positive) and absolute pressure can be measured with same modules meaning you don’t need to buy so many module for greater flexibility. Also, intrinsically safe pressure calibrators are available for use in hazardous areas.
-
product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, Type-N, 2 Port
85092D
The Keysight 85092D RF electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
product
Precision Calibrated Noise Sources
ELVA-1's calibrated noise source ISSN-XX series delivers a uniform level of noise power spectral density within the whole waveguide frequency range. Sources are available in eight waveguide bands covering 26.4-170 GHz.
-
product
Dual Input Thermometer And Infrared Thermometer
We hereby certify that this product has been calibratedand found to be in accordance with the applicableSPECIFICATIONS and STANDARDS.Accuracies of the standard equipment used inthis calibration are traceable to the National Standards