Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
product
Class 1 Sound Level Calibrator
HD2020
The HD2020 sound level calibrator is a portable, battery operated sound source, suitable for sound level meters (portable and laboratory) and acoustic stations.
-
product
Standard Voltage 9 Pin D-Type Cables - Connector to Connector
The connector to connector cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
product
Portable Gas Calibrator
Model T750
Teledyne Advanced Pollution Instrumentation
The Model T750 is a portable, microprocessor based calibrator for precision gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750 is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.The Model T750 can be equipped with an optional UV ozone generator for accurate, dependable ozone calibrations, and production of NO2 when blended with NO gas in the included, internal gas phase titration (GPT) chamber. An optional photometer allows even more precise control of the ozone generator giving accurate and dependable ozone calibrations and enhanced GPT. A number of calibration sequences may be programmed into the non-volatile memory of the Model T750, covering time periods up to a year.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2J30
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Calibration Units
Optical Stroboscope and Tachometer European Calibrator Unit was originally designed for in-house test and calibration of our comprehensive range of Digital Optical Tachometers, Optical Speed sensing products and Stroboscopes.
-
product
Standard Gain Horn Pyramidal Horn Antenna
Elva’s SGPH series of standard gain horn antennas cover the frequency range of 18 to 220 GHz in ten waveguide bands. They can be issued with rectangular or circular waveguide. Lens technology significantly allows decreasing mechanical sizes of horns and correcting beam for the best performance. These horns are ideal solution for measurement gain of other antennas, short range radars and radiometers.
-
product
Standard Round 2m Cables, Shielded, for Higher Current
ST010-S
Connection to digital boards, intended for higher currents. to be used with CPCI-1500, APCI-1500, APCI-1564, APCI-2032.
-
product
Coating thickness XRF Standards
We manufacture high accuracy reference standards capable of calibrating virtually any X-Ray Fluorescence (XRF) coating thickness and composition analysis system.
-
product
Vibration Calibrators
Metra Mess- und Frequenztechnik in Radebeul e.K.
Metra is a leading manufacturer of vibration sources for the calibration of accelerometers, velocity and displacement sensors. Metra's vibration calibrators have some unique features such as a very high payload and variable vibration frequencies.
-
product
Gauges & Calibrators
Ralston Instruments' gauges and calibrators are born from decades of experience working with technicians, project managers and facilities teams responsible for maintaining metrology instruments.
-
product
Standard 0.50 (14.00) - 3.40 (96.00) Non Replaceable General Purpose Probe
C-S-C
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 45Full Travel (mm): 1.14Recommended Travel (mil): 30Recommended Travel (mm): 0.76Overall Length (mil): 395Overall Length (mm): 10.03Rec. Mounting Hole Size (mil): 46.5Rec. Mounting Hole Size (mm): 1.18Recommended Drill Size: 56
-
product
Refractometer Calibration Oils
Calibration Oils are one of the most commonly used materials for calibrating refractometers as they have good traceability, particularly to NIST. Having a high temperature co-efficient, Calibration Oils are best used where strict temperature control is adopted either by Peltier or external waterbath between 10 and 75 °C as well as with refractometers operating at ambient by making use of supplied tables or an RI/°C Temperature Calculator as long as the prism temperature is reliably known.
-
product
Automatic Battery with Filters with Standard Contactors
BATLVF400
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of powerfactor in low voltage instalations
-
product
RTD Calibrators
Practical Instrument Electronics, Inc.
PIE has an RTD calibrator to fit your needs from the PIE 510B single type RTD simulator to the advanced troubleshooting capabilities of the PIE 311Plus. Have you had issues in the past where your RTD calibrator wouldn’t work with some of the instruments in your plant? Our RTD calibrators are guaranteed to be compatible with all process RTD inputs including all brands of smart temperature and multivariable transmitters, PLC input cards, DCS systems and multichannel recorders.
-
product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-F180-1
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
Standard 0.87 (24.70) - 5.40 (153.00) Battery Probe
BIP-12
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Resistance Remark: Probe Resistance Steel: 30 mOhms, Gold plated: 100 mOhmsTest Center (mil): 260Test Center (mm): 6.60Full Travel (mil): 394Full Travel (mm): 10.00Recommended Travel (mil): 315Recommended Travel (mm): 8.00Overall Length (mil): 1,220Overall Length (mm): 31.00
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
product
Acoustic Calibration Services - IEC
Acoustic Calibration Services - IECMake sure you measure correctly! We offer traceable acoustic calibration services according to international IEC and ANSI standards and ensure that your instrument accurately indicates the required measurement parameters. Calibrations are documented, traceable, and digitally signed in cooperation with an accredited calibration laboratory.
-
product
Electronic Calibration Module, DC To 6.5 GHz, 2-Port
N7551A
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors
-
product
Standard 0.66 (18.70) - 4.50 (128.00) Battery Probe
CP-2TB-4
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 39Full Travel (mm): 1.00Recommended Travel (mil): 30Recommended Travel (mm): 0.75Overall Length (mil): 158Overall Length (mm): 4.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-2
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-C
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
product
Three Phase Portable Energy Meter Calibration Equipment
GF302D1
Beijing GFUVE Electronics Co.,Ltd.
The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.
-
product
Standard Test Finger
SMT-1
It with Protection against electric shock device. It according to IEC60335, IEC60884, IEC61032, IEC60529, IEC60065, IEC60035, IEC60950, EN60529, EN60950, GB4706, GB7000, GB9706, UL507, VDE0470, etc.
-
product
Gas Flow Standards
Fluke Calibration offers molbloc/molbox gas flow calibration systems to calibrate flow meters and controllers over a very wide range of flows. The systems are fast, precise and transportable and can be fully automated using COMPASS for Flow software. molblocs, which are the heart of the measurement system, are mechanically stable, gravimetrically calibrated laminar flow and sonic nozzle elements.
-
product
Electronic Calibration Module (ECal), 18 GHz, 7 Mm, 2-Port
N4696D
The Keysight N4696D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4696D is a precision 2-port ECal module that supports 7-mm connectors up to 18 GHz. The plastic storage case for the N4696D is included for securing your ECal module and accessories.
-
product
Phase Angle Voltmeter, Industry Standard
2250A
NAI's 2250A Phase Angle Voltmeter is the most accurate and versatile AC measurement tool in the Synchro/Resolver and LVDT/RVDT marketplace. Considered the industry standard and based on the latest DSP and FPGA technologies, the 2250A substantially extends and simplifies the capabilities of the legacy 2250 model.
-
product
In-Line Speedometer Calibrator Module
Hypertech’s In-line Speedometer Calibrator Module is an in-line module to correct the speedometer and odometer for non-stock tire sizes and/or rear gear ratios. This module is perfect for vehicles with computers that don’t allow for tire size and/or rear gear ratio correction or re-calibrate for tire sizes and/or rear gear ratios outside the range of programmers.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1H-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02