2-wire
resistance measurement method.
-
product
Temperature Sensors
TT420
Features • 2-wire, loop-powered 4-20mA analog output • Attachment probe, sensor, and 2-wire 4-20 mA signal conditioner • Compatible with PLCs, meters, and data acquisition systems • No user calibration • TT420Z 1/4" stainless steel probe • TT420S 1/4-28 threaded stud – screws into any 1/4-28 tap • TT420F mounts onto any flat surface • UL listed, Intrinsically Safe (IS) • Class I, (C, D) and Class II, (E, F, G)
-
product
Party Line Intercom Conversion
COMMS Series
The stand-alone COMMS 300 and the OG-COMMS openGear® units provide a means to interface between two channels of 2-wire party-line intercom audio and two channels of 4-Wire analog line-level signals. The unit is capable of performing auto nulling for each channel with the push of a button. In addition, each of the 4-Wire input and output channel levels are monitored and displayed on easy to understand front panel VU meters.
-
product
TB-2635, Screw Terminal, 8x16, 2-Wire PXI Module Matrix Terminal Block
778839-01
Screw Terminal, 8x16, 2-Wire PXI Module Matrix Terminal Block - The TB-2635 provides the necessary routing to configure the PXI-2529 PXI Matrix Switch Module as a 2-wire 8×16 matrix. You can directly connect the TB-2635 to the front panel I/O connectors of the PXI-2529. The TB-2635 includes screw terminals that provide access to the rows and columns of the matrix.
-
product
Ultra High Density Matrix Switch Card
1260-45
The Astronics 1260-45 offers the highest-density switching matrices in a single-slot C-size VXI module, configurable as 11 different matrices from four 4x16 2-Wire to one 16x16 two-wire. Easily extend this module externally to build a larger matrix in a single VXI chassis to satisfy even the most dense applications.
-
product
REM-11115, 4-Channel, 2-Wire Analog Output Module for Remote I/O
784749-01
4-Channel, 2-Wire Analog Output Module for Remote I/O - The REM‑11115 is an analog output module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11115 from a real-time controller, such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. You can use the REM‑11115 for voltage or current output, and it features a 2‑wire spring terminal connection method. The REM‑11115 has selectable output ranges and short-circuit-proof output channels.
-
product
Inputs Temperature Data Logger – Pt100
HD32.7
The instrument HD32.7 is a robust 8 inputs data logger for Pt100 sensor temperature probes. The probes can be Pt100 with SICRAM module, direct 4-wire Pt100 or direct 2-wire Pt1000.
-
product
20 Channel Multiplexer (2/4-wire) Module for 34970A/34972A
34901A
The Keysight 34901A module for the 34970A/34972A Data Acquisition/Switch Unit is the most versatile multiplexer for general purpose scanning. It combines dense, multi-function switching with 60 channel/second scan rates to address a broad spectrum of data acquisition applications.
-
product
Digital Power Recorder
MPR-601W-02
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Applicable for single phase 2wires and single phase 3wires and 3phase 3wires system*Wide measuring range up to 0~500V/500A*Easy data logging by USB flash memory
-
product
Legacy Liquid Detection Rope Sensor
ENVIROMUX-LDSx-y
For warning of flooding. Detects liquid depth >0.1" (2.5 mm). Minimum puddle: 0.6" (15 mm) diameter. 100% waterproof electronics. Detects any liquid or moisture, except deionized water. RJ45 connector. Voltage Supply: 12VDC. Current Consumption: 20mA. Supports CAT5/5e/6 cable up to 1,000 ft. (305 m). Available water sensor cable (x) lengths: 1/10/50/100/200/400/600/800/1000 feet. Plenum rating: CL2P (UL). Available 2-wire cable (y) lengths: 5/10/20/50/100 feet. Powered by ENVIROMUX-SEMS-16U and SERIMUX-S-x. Regulatory approvals: CE, RoHS. Requires the ENVIROMUX-SEMS-16U and SERIMUX-S-x to operate. Use self-adhesive clips (ENVIROMUX-CLP10-LD) to prevent sensor rope cable from shifing after installation. ENVIROMUX-CLP10-LD includes 10 clips.
-
product
Modbus or Laurel ASCII ProtocolSerial Output DIN Rail Transmitters
Laureate TM Series serial output transmitters can be jumpered for two signal levels: RS232 or RS485. Two serial protocols are selectable in software: Modbus or Laurel's Custom ASCII.Modbus protocol operation is fully compliant with the Modbus Over Serial Line Specification V1.0 (2002) for 2-wire, half-duplex connection.
-
product
16-Channel Multiplexer (2 / 4-Wire) Module for DAQ970A and DAQ973A
DAQM902A
DAQM902A 16 Channel Multiplexer (2/4-wire) Module. Reed relays with high voltage switching of up to 300 V and scan speed up to 250 ch/s.
-
product
LVDT/RVDT Simulation Board
75DL1
The 75DL1 is a cPCI LVDT/RVDT Simulation Board that provides eight 2-wire or four 4-wire transformer isolated programmable outputs. It provides wrap-around self-test, PXI compatibility, optional Excitation Supply, and is available for Military or Commercial applications.
-
product
4x8 2 Wire USB Modular Switch Matrix
U2751A
The U2751A USB Modular Switch Matrix offers a flexible connection path between the device under test and the test equipment, thus allowing different instruments to be connected to multiple points on the device under test at the same time. This instrument is able to support measurements at a high bandwidth of up to 45MHz. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity
-
product
SWB-2814, 8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781421-14
8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2814 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
product
IEC60695-11-2 Single Wire And Cable Vertical Burning Tester
CX-D12
Shenzhen Chuangxin Instruments Co., Ltd.
It’s strictly designed according to IEC60695-11-2, IEC60332-1, GB/T18380.11-2008, GB/T18380.12-2008 etc. Stainless steel screen with a sliding burner handle support for approaching or movingback the flame from the sample under test according to the CEI standards for test on cables.
-
product
PXI High Density Multiplexer: 99-ch, 2-Wire, 100Vrms/1A, Armature Relays
M9103A
The M9103A, a high-density, high-power 99-channel multiplexer routes many different channels to a single point. The switches operate in a break-before-make mode that ensures no two points are connected at the same time, or multiple channels can simultaneously connect if needed. This module is ideal for routing multiple analog signals to a measurement device in an automated test environment (ATE) or data acquisition systems. Each channel switch has a high and low for 2-wire switching. The high-quality armature relays are capable of switching up to 100Vrms, with up to 60W of power. Choose from the durable connector block or standard cable connections.