Bulk Current Injection
-
Product
Concrete Bulk Resistivity
RCON
-
Giatec RCON™ is a non-destructive device for measuring the electrical resistivity of concrete specimens in the laboratory without any additional sample preparation requirements. This measurement can easily be made on the same concrete samples that are currently used for the compressive strength testing of concrete.
-
Product
Combinated Current Clamps
-
PeakTech Prüf- und Messtechnik GmbH
Measure small direct and alternating currents up to 2 A with 1 mA resolution. The device measures the current indirectly via the surrounding magnetic field, so it is measured without contact when the clamp jaws enclose the current-carrying conductor (single wire).
-
Product
Current Integrated Sources
CIS
-
The CIS current integrated source was designed to provide a stable alternating current source for the electricity meter test equipment, and in laboratories. The output current is isolated and independent from the mains voltage. Different CIS versions are available depending upon the values of output power and output current required.
-
Product
High Current Sensor
HCS-BTA
-
Vernier Software & Technology, LLC
Use the High Current Sensor in experiments that involve currents larger than 1 A, such as solar panels, hand generators, and other alternative energy projects.
-
Product
Primary Injection Test System
-
HAOMAI Electric Test Equipment Co., Ltd.
Primary injection testing is suitable for testing over-current trip relays attached to a circuit breaker.
-
Product
Bulk Acoustic Wave Technology
BAW
-
Macom Technology Solutions Holdings Inc.
MACOM’s BAW product portfolio is ideal for high performance Industrial, Aerospace, Defense, and Communications applications that require critical frequency filtering. Our high-performance RF filters enable our customers manage signal integrity in the 1 to 6 GHz frequency range. Bulk Acoustic Wave Resonators consist of two metal electrodes above and below a layer of a piezoelectric material. The piezoelectric material converts an electrical signal to a mechanical signal and vice versa. The metal electrodes provide the connections to/from the piezo material. The frequency at which resonance occurs depends on the thickness of the combined metal-piezo-metal stack. Advances in thin-film piezoelectric fabrication have enabled BAW resonators to meet RF filtering challenges up to 6000 MHz using standard MEMS fabrication process. High-performance BAW resonators-based RF filters are made of piezoelectric material having high Q-factor (>3000) and high coupling coefficient. Currently, no competitive technology provides the same high performance for RF filter applications when compared to BAW resonator-based RF filter up to 6000 MHz for the same size and cost.
-
Product
NI-9247, 50 kS/s/ch, 50 Arms, 147 Apk, 24-Bit, 3-Channel C Series Current Input Module
783589-01
-
50 kS/s/ch, 50 Arms, 147 Apk, 24-Bit, 3-Channel C Series Current Input Module - The NI‑9247 is designed to support direct ring lug connectivity to the three-phase high-current measurements of 1 A and 5 A current transformers (CTs). It is optimized for power, energy, and industrial applications. The safety features, certifications, input ranges, overvoltage ranges, and connectivity are well suited for applications such as power quality monitoring and metering, utility pole-mounted smart switches, utility pole-mounted smart grid reclosers, substation merging units, industrial machine measurements, health monitoring, predictive maintenance and prognostics, and phasor measurement units (PMUs).
-
Product
Leakage Current Tester
-
Test Voltage : - 1V to 500V DC settableAccuracy : ± 1% of set Value ± 1digitLeakage Current : - Accuracy - ± 0.5% ± 1digitDigital Model – 19.99μA / 199.9 μA / 1.999mA / 19.99mAAnalog Model - 10μA /25μA/100 μA/1mA/2.5mA/10mASeparate Indication for Charge / Measure and Discharge modeAvailable in Digital Version Also
-
Product
Current Transformer
ST-6RCT
-
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 400~600
-
Product
Current Measurement Probes
-
Comprehensive line of clamp-on current probes covers the entire spectrum of applications, from electrical panels to substations. AEMC Current Probes measure current without interrupting the circuit under test and extend the measuring capabilities of DMMs, recorders, power meters, and loggers. The numerous jaw sizes are designed to accommodate a wide variety of conductor diameters and ranges. Available for AC or DC measurements.
-
Product
Precision Current Shunt
-
Has five precision selectable Ultra stable Current Shunts which ranges from 0.0001 to 1Ω. The Shunt T/C is less than 10ppm, and the internal current meter will measure from 1μA to 1000Amps.
-
Product
Current Transformer Tester
CTT
-
The CTT is designed to test the current transformer ratio, Phase shift, Polarity, Excitation, Saturation, Winding resistance and Insulation resistance using the voltage method in compliance with ANSI/IEEE C57.13.1 and IEC 60044-1 standards, where voltage is applied to the secondary X terminals of the current transformer.
-
Product
Current Transformers
-
The Institute of Electrical and Electronic Engineers defines a current transformer (IEEE Std C57.13) as “a transformer intended to reproduce in its secondary circuit, in a definite and known proportion, the current of its primary circuit with the phase relations substantially preserved”. Its primary winding is connected in series with the conductor carrying the current to be measured or to be controlled and its secondary winding is connected to the measuring, protection or control devices. Osborne designs and manufactures current transformers which are used for instrumentation applications, others which are used for power system synchronizing applications and others which are used in protection circuit application. They have been designed to meet specified current ratios, burden impedance and transformation errors.
-
Product
Current Transformer
CT
-
The split-core current transformers are easily installed with the snap on design.
-
Product
Current Pulsers and Laser Diode Drivers (Pulsed Current)
-
These instruments generate current pulses whose amplitude is largely independent of the load voltage. This makes them ideal for pulsing device whose voltage may vary with time (for instance, the voltage drop of laser diodes may vary with temperature, or explosive squibs which change impedance during ignition). This voltage independence is a trade-off with speed. If faster rise times are required, consider using pulsed voltage instruments instead.
-
Product
Magnetic & Current Sensors
-
From the International Space Station to a simple electronic compass, we can provide a solution to meet your magnetic semiconductor needs. The F.W. Bell® product line was founded in 1944. Since then we have been a pioneer in developing instrumentation to measure electric current and magnetic fields.
-
Product
Industrial Current Sensors
RCT
-
Power Electronic Measurments Ltd
The RCT range of AC current transducers are designed for permanent or semi-permanent installation and are available with industry standard outputs.
-
Product
Primary Injection Testers
AT-10B
-
ETI’s AT-10B autotransformer steps-down 480V outputs to 240V outputs. This portable autotransformer allows ETI’s PI-1600 or PI-800 circuit breaker testers to be used at full-capacity on 240 and 480 VAC lines. The unit provides 240 VAC at 10 kVA, is housed in a rugged ABS enclosure approximately 22″ x 11″ x 22″, and weighs less than 125 lbs.
-
Product
Injection Transformer
J2100A
-
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
Product
Current Clamps
-
Due to its variable measuring functions, the digital clamp meter can be operated universally. Useful details, such as the large display, manual or automatic ranging and measurement position lighting, makes operation particularly easy and reliable.
-
Product
Current Sensing
-
voltage-output, current-sensing amplifier family that integrates an internal shunt resistor to enable high-accuracy current measurements at common-mode voltages that can vary from 0 V to 36 V, independent of the supply voltage. The device is a bidirectional, low- or high-side current-shunt monitor that allows an external reference to be used to measure current flowing in both directions through the internal current-sensing resistor sensor. The integration of the precision current-sensing resistor provides calibration equivalent measurement accuracy with ultra-low temperature drift performance and ensures an optimized Kelvin layout for the sensing resistor is always obtained.
-
Product
AC Current Transducer
iDVM 333
-
The iDVM 333 AC Current Transducer plugs into the iDVM 510 multimeter and measures current (as AC millivolts) with no need to break the circuit. Special Introductory Price: $52.50FeaturesTransformer jaws that detect AC current flowing through a conductorSelectable sensitivity between 1mV/A and 10mV/AHand Guard to protect your hand for safetyLarge, easy-to-operate trigger opens the transformer jaws
-
Product
Primary Injection Test Systems
-
Primary current injection testing is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.
-
Product
Leakage Current Sensors / Small Current Sensors
-
ChenYang Technologies GmbH & Co. KG
This current sensor is based on magnetic modulation and compensation principle, and can beused for measurement of small DC current and leakage current, current difference between two ormore conductors.
-
Product
Current Transformer Testers
-
Vanguard Instruments Company, Inc.
Performs CT excitation, current-ratio, polarity, and phase angle testsMeasures insulation resistance and winding resistance of the CT seconday windingsMeasures the CT's secondary burdenTest record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-commentsBuilt-in 4.5-inch wide thermal printerPlot Multiple Saturation CurvesStores up to 128 CT test plans and 140 test records internallyUSB, Bluetooth, and USB Flash drive interface
-
Product
Density Determination and Bulk Density
-
Consisting of 2 incremental displacement transducers 25 x 0.01 mm (measurement of volume change over path) with interface for connecting the displacement transducers with RS 232 C interface for PC, complete with Windows software with real-time display of uplift over time including trial database and option for log output.
-
Product
Integrated Current Sensors
-
Current sensors have to be smaller, smarter, cheaper. LEM’s R&D is actively developing a range of ICS to reduce the footprint of the current sensing function and simplify the integration of current measurement in a wide range of applications in automotive, industrial, or residential.
-
Product
Multi-Channel, Programmable Current Source
CS-48-100
-
The Model CS-48-100 is a multi-channel, programmable current source. Developed for both semiconductor and digital superconductor electronics, it is computer-controlled and features 48 low noise current source outputs. Each source output has the capability to both set and read back currents and can be set to a zero current high Z mute state. Each of the 48 sources are optically coupled for control and are sourced from their own secondary winding for complete galvanic isolation. The device consumes a maximum of only 80 W and handles a maximum load current of 4.8 A total over all outputs. Operating over a range of 0-100 mA on each channel, the device features accuracy of +/-25 ?A. The mute state can be set thru a rear panel interlock or from the front panel button for maximum circuit protection. The unit can be mounted in a standard-sized rack.
-
Product
Current Sensors and AC Current Sensors
-
Current sensors are designed to monitor the presence or absence of AC or DC current and are available in an assortment of standard & custom models with hermetic or gasket seal models designed to withstand severe environmental conditions.