Temperature Calibration Baths
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-02
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Linear Measurement Kit
55280A
Mechanical Calibration Kit
The Keysight 55280A Linear Measurement Kit, used with the Keysight 5530 Laser Calibration System, includes the optical equipment needed to measure linear distance (displacement) and velocity. The kit contains a Keysight 10766A Linear Interferometer, two Keysight 10767A Linear Retroreflectors, mounting hardware, andtransit case.
-
Product
USB Temperature Measurement Bundle
Temperature Input Module
The USB Temperature Measurement Bundle includes a CompactDAQ Chassis with the C Series Temperature Input Module for temperature measurements. The USB Temperature Measurement provides a portable, USB-based sensor measurement system with features such as anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements.
-
Product
Calibration Lead Precision Resistor, Triple
40-975-009-SL3
Calibration Lead Cable Assembly
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
Mechanical Calibration Kit, 18 To 26.5 GHz, Waveguide, WR-42
K11644A
Mechanical Calibration Kit
The Keysight K11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the Thru-Reflect-Line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
Product
1 Mm Calibration Kit
85059B
Mechanical Calibration Kit
The Keysight 85059B is a 1.0 mm calibration kit designed for vector network analyzer systems operating over the frequency range of DC to 120 GHz. The opens, shorts and loads in this kit are optimized to provide accurate and traceable calibrations over the specified frequency range. The 85059B with 85059V 1 mm Verification kit are replacements for the 85059A 1 mm calibration/verification kit.
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
785189-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Calibration Lead Precision Resistor - Single
40-975-009-SL1
Calibration Lead Cable Assembly
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
Standard Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036B
Mechanical Calibration Kit
The Keysight 85036B calibration kit contains precision 75 ohm type-N standards used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 3 GHz.
-
Product
Economy Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052D
Mechanical Calibration Kit
The Keysight 85052D economy mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection. Connector gauges may be ordered separately.
-
Product
NI-9212, 8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module
785259-01
Temperature Input Module
8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module - The NI‑9212 offers channel‑to‑channel, isolated thermocouple input channels. The NI‑9212 channel‑to‑channel isolation protects channels from continuous voltages up to 250 Vrms and transient (withstand) voltages up to 1500 Vrms. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels such as white goods testing, in-vehicle data logging, battery stack testing, as well as in various other noisy industrial environments.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-02
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Linear/Angular Measurement Kit
55281B
Mechanical Calibration Kit
The Keysight 55281B Linear/Angular Measurement Kit is part of the Keysight 5530 Laser Calibration System and enables the system to measure both linear velocity along a machine's travel path as well as rotation about an axis perpendicular to the axis of motion (pitch and yaw).
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (f)
85561A
Mechanical Calibration Kit
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight.
-
Product
Liquid Calibration Baths
-
Designed for calibration of temperature control devices that contain hazardous or corrosive fluids. Meets Class 1, Division 1 requirements for operation in a hazardous environment. CSZ explosion proof liquid calibration baths are designed to calibrate a large number of temperature sensors which contain a variety of different types of hazardous fluids. The sensors are typically calibrated in the same fluid used in the sensing element of the control devices per specification.
-
Product
Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm
85132F
Calibration Cable
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.
-
Product
sbRIO-9213, Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
781210-01
Temperature Input Module
Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The sbRIO-9213 is a high-density thermocouple input module that is designed for higher-channel-count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The sbRIO-9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO-9213 features NIST-traceable calibration and a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
Product
Calibration Kit YAV90MMU
YAVMMUCK
Mechanical Calibration Kit
The Calibration Kit includes the tools for YAV90MMU test and calibration. As the YAV90MMU is the core of the YAVPack Bundle (YPB), this calibration kit is also an option for the YPBs.
-
Product
Dry Block And Bath Calibrators
-
These units are used to calibrate sensors such as thermistors, thermocouples and RTD's. Different temperature ranges, accuracies and stabilities to cover most sensor specifications.
-
Product
Cal Kit, 4-in-1 OSLT, DC To 26.5 GHz, 3.5 Mm(f)
85521A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
Precision Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052C
Mechanical Calibration Kit
The Keysight 85052C precision mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection.
-
Product
Diagonal Measurement Kit
10768A
Mechanical Calibration Kit
The Keysight 10768A Diagonal Measurement Kit is designed for use with the Keysight 5530 Laser Calibration System. It allows linear measurements to be made on the four body diagonals of a machine tool's working volume. These measurements document the machine's capability and quickly perform a complete check of volumetric positioning performance. In addition, long-term drift tests can be performed over hours or days, showing possible effects of temperature on geometry.
-
Product
Portable Temperature Calibrators
-
Portable temperature calibrators (dry-well calibrators) are electronic controllers which automatically, quickly and dryly supply a temperature. Due to the high reliability, accuracy and simple operation, portable temperature calibrators are particularly suitable as a factory/working standard for the automatic testing and/or calibration of temperature measuring instruments of all types. A major advantage is offered by the large sleeve diameters and the fast, stable temperature control, since, as a result of these characteristics, the time for calibration can be used very effectively.
-
Product
Temperature Controlled Water Bath
WB
-
Digital temperature controllerStainless steel tank with structural steel baseTiming circuit refreshes water for a full two minutes each hour preventing buildup of weak acid and stale waterWater level adjustable by standpipe changeOverhead wire tray with openings for optional test leadsHolds 15 SLI storage batteries (BCI group 24)
-
Product
Humidity and Temperature Calibration
-
The most comprehensive temperature, humidity and dew-point calibration offering on the market today.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (m)
85562A
Mechanical Calibration Kit
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight
-
Product
REM-11120, 4-Channel Thermocouple, 1-Channel Voltage, Temperature Input Module for Remote I/O
784750-01
Temperature Input Module
4-Channel Thermocouple, 1-Channel Voltage, Temperature Input Module for Remote I/O - The REM‑11120 is a temperature input module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11120 from a real-time controller such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. The REM‑11120 also has an adjustable filter time for improved measurement quality and optional external cold junction compensation (CJC) or PT100 resistance temperature detector (RTD) measurements.
-
Product
Temperature Calibration
-
Trescal provides full Temperature Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Temperature Calibration services can be delivered at your site or at our lab. Accreditations for our temperature calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Liquid Thermal Shock Baths
TSB Series
-
CSZ's Liquid thermal shock chambers consist of separately controlled hot and cold baths. Product is submersed in fluid and thermally stressed between the hot and cold baths, resulting in immediate product temperature changes. CSZ uses perfluorinated fluid that does not coat the product or conduct electricity for use in both the hot and cold baths to eliminate cross contamination and reduce evaporation losses.
-
Product
Portable Calibration Baths
6109A / 7109A
-
The Fluke Calibration 6109A and 7109A Portable Calibration Baths are liquid baths that let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other portable baths in this class. Larger than micro baths, up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges. Two bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe. Professionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.