Discharge
-
Product
Battery Load Banks
-
Kongter Test & Measurement Co., Limited
Kongter offers many different models of battery load units for real capacity test in various industries. With our customized solution, users of different applications will find their exact models as per their needs. With its optional DAC (Data Acquisition Case), you could easily monitor voltage of each cell on PC during battery discharge test.
-
Product
Portable PD Monitoring
ASM-P
-
The ASM-P can be configured with up to 32 PD sensor channels. If excessive discharge is detected, the ASM-P raises an alarm that can be configured either locally or by email/SMS. This enables the long-term assessment of plant conditions to be carried out quickly and easily, from any remote computer.
-
Product
Partial Discharge Testing Equipment
PD-Analyser
-
This is an ‘All in One’ solution for testing and analysing partial discharges in the insulation of high-voltage transformers, cables, GIS and electric machines. The DIMRUS ‘PD Analyser’ help diagnose their insulation state and find any type of defects very effectively.It can be used for temporary or constant monitoring of partial discharge in medium and high voltage systems and cables of any rated voltage.The PD Analyser is the most useful device for condition estimation of high-voltage insulation. This multipurpose device is designed for -Partial discharge measuring in high-voltage insulation at a high noise level.Fast detecting of the defects in different high-voltage equipment and identifying how dangerous they are.
-
Product
48V / 300 Amp Load
BD18-48P
-
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 48V and 50V, (24 or 25 cells at 2V each), battery systems and is extremely cost effective.
-
Product
Battery Cell Formation System
17000 series
System
Chroma 17000 series is specifically designed for the formation of Lithium Ion and Lithium Polymer secondary batteries. The 17000 series is a complete turn-key system, including carrier trays, robust battery probe contacts, high quality charge/discharge modules and intuitive software all under computer control. Patented Battery Voltage Tracking (BVT) DC-DC conversion power modules minimize power consumption in battery charging, and Energy Recycle Modules (ERM) recycle the discharged energy directly back to the DC power system for increased power efficiency. These power saving designs provide a planet friendly solution along with cost savings by reducing energy consumption. The intuitive software provides a flexible selection in the charge/ discharge channel, current rating, and modules under test. These features allow the Series 17000 to be used for final cell development, pilot line production, high volume production and ongoing reliability monitoring/quality control.
-
Product
Photoelectric Direct Reading Spectrometer
TY-9610
-
Wuxi Jinyibo Instrument Technology Co., Ltd.
1, Optical SystemStructure: Pa type - RungeRaster: Radius of curvature: 750mmIncident slit width: 20 μ mExit slit: high-precision photolithography of the entire slit, according to different elements set up 30u-75u slit width.Detector: Photomultiplier tube ( PMT ) detector2, all digital excitation light source1. Fully digital intelligent composite light source DDD technology, which can automatically adjust the excitation parameters of light source according to the excitation characteristics of different materials, and truly realize full digital control. 2. Using the all-digital control mode, high-energy pre-combustion technology ( HEPS ), ultra-stable energy release stimulates the sample in an argon atmosphere. 3. The application of all-digital light source improves the measurement accuracy and similarity of the sample, improves the sample excitation speed, improves the spark stability, and makes the sample have better reproducibility. The maximum discharge current reaches 400A .
-
Product
Full-Featured Life Cycle Test System
LCV
-
Configurations for testing to industry standards: IEC, SAE, BCILife Cycle Testing: Perform charge/discharge cycling of batteries or modules to obtain charge and discharge capacity, energy and DC internal resistanceAutomotive Battery TestingStarting, Lighting and Ignition (SLI) TestingTraction Battery Testing
-
Product
MASTER FUEL PRESSURE TEST KIT
FIT550
-
*Performs running, residual, rail and flow rate pressure tests*Large, easy-to-read 3-1/2" dual-scale gauge reads 0-100psi and 0-700 kPa*Kit includes: 50+ adapters, fittings, 48" hose, pressure relief and fuel discharge hose to test most domestic and foreign fuel injection systems*Also includes quick release couplers and adapters to fit other fuel injection test kits*For use with gas engines only
-
Product
FaithTech Regenerative High-power Programmable DC Load
FTR9000 Series
-
Shenzhen FaithTech Technology Co., Ltd.
FTR9000 series is a regenerative programmable DC electronic load. It not only has the function of traditional consumable load, but also cleanly feeds the energy consumed by traditional load back to the power grid to achieve the purpose of energy conservation. It can be widely used in new energy equipment testing, lithium ion, fuel and other battery discharge testing, automatic testing system, AC/DC, DC/DC and other one-way module product testing and aging. The product is equipped with rich communication, programming interfaces, color screens and a variety of text menu interfaces, which is easy to operate and intuitive. It is a common equipment in the power electronics, new energy, sensors, motor drives, system integration and other industries.
-
Product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
-
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
Product
Partial Discharge Detection Calibration Device
-
Hangzhou Xihu Electronic Institute
Calibration Device of Transient Earth Voltage PD detector, calibration device of ultrasonic PD detector, calibration device of high frequency PD detector, calibration device of ultra high frequency PD detector.
-
Product
Battery Charger-Analyzer for small battery systems (up to 10A-Hr)
miniMasterCharger
-
The miniMasterCharger is an instrument designed to charge, trickle charge and analyze (discharge) Nickel-Cadmium, Sealed Lead-Acid and other types of rechargeable batteries.With its multiple modes of operation of Constant Current Charge (dual and single rate), Constant Current & Float Charge, Constant Current & Peak Stop Charge, Automatic Discharge (analysis), Resistance Discharge (analysis) and Full Discharge (deep cycle), the miniMasterCharger can satisfy the requirements of most small (0 to 10 A-hr) rechargeable battery systems.The instrument features safety interlocks to protect the operator, the charger and the battery in the event of reversed polarity connection, short circuit, open circuit (no load) and Overvoltage conditions.
-
Product
Acoustic Imaging Cameras
Si1 and Si2 Camera series
-
Helps you significantly lower costs associated with mechanical bearing issues and partial discharge on electrical equipment. It also enables you to drastically reduce leaks in your facilities, cutting down expenses related to compressed air and gas leaks.
-
Product
Coupling Decoupling Network for Communication Lines
CDN61000-5C
-
• Application Range: ≤4kV, 1.2/50us pulse, 8 wire unshielded twisted pair (UTP) • Test Voltage: Max 4KV, 2 kV (1.2/50 µs pulse when RJ45 connector is connected. Maximum test voltage is 1.5kV when RJ45 female is unconnected or auxiliary terminal is not protected.) • Coupling mode: 90V gas- discharge tube+250ohm Resistor/Each Wire, 8 Wires Simultaneously-Ground (Common Mode) • Input and output interface: RJ45 connector • Terminal layout (RJ45 connector): First pair of lines: pins 1/2 Second pair of lines: pins3/6 Third pair of lines: pins 4/5 Fourth pair of lines: pins 7/8 • Max. operating speed: 1000MBit/s • Max operating voltage: Max 50V DC • Max operating current: Max 1A Related Instruments
-
Product
Transmission Line Pulse Testing
-
Transmission Line Pulse testing, or TLP testing, is a method for semiconductor characterization of Electrostatic Discharge (ESD) protection structures. In the Transmission Line Pulse test, high current pulses are applied to the pin under test (PUT) at successively higher levels through a coaxial cable of specified length. The applied pulses are of a current amplitude and duration representative of the Human Body Model (HBM) event (or a Charged Device Model – CDM – event in the case of Very Fast TLP, or VF-TLP).
-
Product
Power ICs - Smart Load Switches
-
Combining multiple functions in a single IC, Vishay smart load switches eliminate the need for external circuitry . A simplified GPIO interface allows for power distribution and sequencing of multiple sub-systems. Slew-rate-control devices provide a controlled supply ramp to reduce inrush current, while fault protection and isolation switches increase robustness with reverse current, overtemperature, current limiting, and short circuit protection features. The ICs offer quick output discharge and small footprints, while their integrated design saves PCB space compared to discrete solutions, reduces BOM counts, and lowers manufacturing costs.
-
Product
Universal Partial Discharge Measurement and Analysis System
MPD 800
-
Our MPD 800 universal partial discharge (PD) measurement and analysis system represents the next generation of our widely-used and innovative MPD PD testing technology. Enhanced and newly-added hardware and software features ensure highly-sensitive multi-channel PD measurements for reliable, industry-standard PD testing on a variety of electrical equipment and components.
-
Product
Partial Discharge
-
Partial discharge (PD) is a local electrical discharge that occurs in imperfections or inhomogeneities. The partial discharge measurement is a so-called “non destructive test” to determine the quality of insulating materials. On the contrary of pure high-voltage test, th test item is not pre-damaged at low PD levels.
-
Product
Static Honest Meter
-
Sataton Instruments Technology CO., Ltd
Static honest meter is professional designed to determine the attenuation of static electricity, corona discharge time, static voltage attenuation half-life, static decay curve and other electric property of fiber, yarn, fabric, textile or plate materials. It is suitable for measuring the diffusibility of static in the testing samples.
-
Product
Battery Load Bank
K-3980
-
Kongter Test & Measurement Co., Limited
Kongter offers a series of customized DC load banks with many different models for constant current battery discharge test and battery capacity test. They cover a wide voltage range from 12V to 480V nominal voltages with current up to 600A. They are widely applied in various industries. With its optional battery Data Acquisition Case (DAC), discharge values of EACH cell could be monitored in battery load bank and PC software simultaneously by using Kongter’s data view software.
-
Product
Battery Analyzers
Beta D-50
-
*Analyzer for any type of battery.*Adjustable constant current discharge from 0 to 50 Amps.*Set for Amp-Hour capacity reading.*Accept or Fail lights Indicators for a GO/NO-GO Test.
-
Product
Partial Discharge Testing Of Transformer & Localization System
AE-150™
-
The is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors' data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors.
-
Product
Multifunctional Safety Tests
-
Manufacturers of electrical or electronic products are required by law to carry out an electrical safety test before placing them on the market. This final test takes place at the end of the manufacturing process and is therefore also referred to as an EOL test (end-of-line). Depending on the prescribed standard and directive, the following parameters are tested:- Leakage current and discharge current- Insulation resistance or the insulation strenth- Dielectric strength or electric strength- Correct installation of the protective conductor (ground continuity and ground bond test)- Faultless functioning of the product under the conditions defined for intended use (function or run test
-
Product
Tailor-Made to Simulate Low-Temperature Plasma Sources and Systems
Plasma Module
-
The Plasma Module is tailor-made to model and simulate low-temperature plasma sources and systems. Engineers and scientists use it to gain insight into the physics of discharges and gauge the performance of existing or potential designs. The module can perform analysis in all space dimensions 1D, 2D, and 3D. Plasma systems are, by their very nature, complicated systems with a high degree of nonlinearity. Small changes to the electrical input or plasma chemistry can result in significant changes in the discharge characteristics.
-
Product
Dual Surge Current Generator
MIG0624T-K12
-
Designed for testing telecom surge protection devices according to ITU-T K12. The generator has two indepedent impulse outputs which allow testing of two and three terminal protection devices such as gas discharge tubes (GDT). The generator can be configured for two terminal devices or with the outputs in parallel to increase the current impulse for two terminal devices.
-
Product
RC Meters
-
Provides the. capacitance to be measured at a frequency which is reciprocal to the. product of the discharge resistance and the measured capacitance.
-
Product
ESD - Simulator
SESD 230
-
The test generator SESD 216 simulates electrostatic discharge as defined in the standard IEC / EN 61000-4-2. Depend on the Equipment Under Test (EUT) and the test set-up for laboratory tests the IEC standard shows two test methods
-
Product
Portable Touchplate Wrist Strap Tester
-
Testing your ESD Wrist Strap system before handling electrostatic sensitive is extremely important. ESD events can go unnoticed by feel and sight. While a static discharge into a door knob (we’ve all done it!) can be thousands of volts, an ESD event can be as little as 10V, and you will not feel this. This is a no-frills, “go-no-go” type tester, but portable. Sure you could put this at your entry point, but where it really shines is in special remote applications. Keep one in your tool box, bag or Field Service Kit.
-
Product
Life Cycle Module Testing System
LCN
-
Full featured test system for quality control and R&DLife Cycle Testing: Perform charge/discharge cycling of batteries or modules to obtain charge and discharge capacity, energy and DC internal resistanceAutomotive Battery TestingStarting, Lighting and Ignition (SLI) TestingTraction Battery Testing
-
Product
Transformer Winding Resistance Meters
RMO TD Series
-
The RMO-TD Series On-Load Tap & Winding Resistance Analyzer is designed for the measurement of winding resistance of inductive elements, and for tap changer analysis. The RMO-TD series is based on the latest technology, using the most advanced switching technology available today. The RMO-TD series is accurate (0.1%), powerful (up to 60 A) and lightweight. It generates true, ripple-free DC current with automatic metering control and a discharge circuit.