Frequency Calibrators
-
Product
Calibrators
-
Portable and user friendly calibrator, ideal for checking sound level meters and dosimeters on the measurement site, or in the laboratory.
-
Product
Frequency Dividers
-
Precision Test Systems manufacturers' various divider boards as options to its range and frequency standards and distribution amplifiers.
-
Product
Calibration Modules and Kits
-
Keysight Calibration Modules achieve more precise and accurate measurements for your testing needs. Regular calibration is required to ensure your high-performance measurement equipment is operating to its specified performance, and our Calibration Modules and Kits make the calibration of your equipment fast, easy, and accurate.
-
Product
MOSFETs For High Frequency Amplifier
-
The MOSFETs shown below are best suited for amplification of high-frequency signals.
-
Product
Frequency Extension Heads for Vector Network Analyzers
FEV
-
These frequency extension modules connect to your existing test ports and leverage the inherent microwave network analyzer’s performance and features to display full port S-parameters: Two measurement architecture available: 1-path/2-port and fully reversing 2 port. Waveguide calibration kits are available as separate accessories.
-
Product
Low Frequency 3-Way Power Dividers To 1500 MHz
-
Pulsar Microwave manufactures 3-way power dividers from 1 MHz to 1.5 GHz in both surface mount and connectorized packages. They are rated for an input power of 1 watt maximum for a load VSWR of 1.20:1 or better. This series of 3-way power dividers are currently offered in four outline packages. The hermetically sealed outline 301 and surface mount outline B are useful in portable applications where space is premium. Outlines 412 and 433 are connectorized versions in cross or in-line format, respectively.
-
Product
Automatic Calibration Module
ACM4509
-
ACM4509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full four-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.
-
Product
Three Phase Electrical Power Calibrator
6003A
-
The Fluke Calibration 6003A Three Phase Electrical Power Calibrator is the most cost-effective way to get the superior accuracy and performance of three independent phases in one instrument. It is an ideal solution for calibration laboratories, electronics manufacturers, electric utility meter shops, and other organizations that manufacture and maintain energy meters, power quality analyzers, and similar tools.
-
Product
Hart Multifunction Calibrator
Model 26 / 26 H
-
Kusam Electrical Industries Limited
The multi-functional field process calibrator with high accuracy and stability, which can provide powerful measurement or output functions & other special functions to meet all the calibration work for field process control.
-
Product
Digital Instantaneous Frequency Measurement Receivers
DIFM
-
Mercury Systems offers a range of standard high-performance broadband Digital Instantaneous Frequency Measurement (DIFM) receivers and Digital Frequency Discrimination (DFD), which act as functional building blocks in many military electronic warfare systems. Examples include electronic counter measures (ECM) systems, electronic surveillance measures (ESM) systems and radar warning receivers (RWR).
-
Product
Calibration
RF Test Equipment
-
We calibrate following types of RF test equipment:EMF test systems (frequency selective)EMF test systems (broadband)Field strength transfer standards (e.g. RefRad)Line Impedance Stabilisation Network (LISN)Cable, attenuator, couplerAntennaField Probe
-
Product
CableEye Tester Calibration Verification Board | Cable & Harness Tester
CB50
-
Populated with precision resistors, it allows users to determine empirically whether the tester requires calibration. The CB50 may be used on all CableEye models. The CB50 is intended for periodic verification of tester calibration. To ensure that resistance measurements remain accurate, CAMI recommends yearly calibration. However, depending on environmental conditions and usage, testers may need calibrating more or less frequently.
-
Product
Calibration Kit
N612
-
*N612 Calibration Kit, * Frequency Range: up to 6 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.
-
Product
Air Pollution Multigas Calibrator
APMC-370
-
Dilution of gases with high accuracy and precision requires high quality MFC’s, especially for high dilution ratios and ranges. Consequently HORIBA’s APMC-370 is equipped with digital MFC’s. These MFC’s are factory calibrated, optional also with a special Polynomial Calibration. HORIBA Europe‘s APMC-370 is designed to calibrate gas analyzers manually, remotely controlled or automatically. It is installed in air pollution monitoring stations for quality assurance in the laboratory and also in the production of gas analyzers.
-
Product
Digital Attenuator Operating Frequency of 1 to 20 GHz
LDA Series
-
The LDA series of Lab Brick® RF and Microwave Programmable Digital Attenuators includes 50 Ohm and 75 Ohm bidirectional RF step attenuators with calibrated operation up to 20 GHz. These USB powered and controlled units require no additional DC supply voltage. They are easily programmable for fixed attenuation or swept attenuation ramps directly from the included GUI. Lab Brick Digital Attenuator API DLL, Linux drivers and LabVIEW-compatible drivers are also available for custom programming applications.
-
Product
Bench Digital Multimeter, Calibrated, 1 kV, 10 A, 3.8 Digit
72-1015 CAL
-
The 72-1015 CAL from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
Product
Bench Digital Multimeter, Calibrated, Data, 1 kV, 10 A, 3.8 Digit
72-1015 CAL D
-
The 72-1015 CAL D from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
Product
Time Frequency Analysis Function
OS-0527
-
This function can evaluate transient phenomena that were difficult to capture by FFT analysis, and display clearly time change of the frequency component while maintaining its frequency resolution . The OS-0527 is equipped with STFT (Short Time Fourier Transform) and Wavelet transform.
-
Product
Three Phase Portable Energy Meter Calibration Equipment
GF302D1
-
Beijing GFUVE Electronics Co.,Ltd.
The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.
-
Product
Palm Size Digital Multimeter, Calibrated, 1999 Count, Mean Value, Manual Range, 3.5 Digit
72-7770 CAL
-
The 72-7770 CAL from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.
-
Product
Partial Discharge Measurement Calibrator
DAC-CP-2
-
DAC-CP-2 is a calibrator for partial discharge measurements.The electric charge enables to generate up to max 10000pC.It is battery-operated and can be charged by connecting to the measuring instrument (DAC-PD-3).
-
Product
Calibrator
-
Shijiazhuang Suin Instruments Co., Ltd.
Is a device used to adjust an instrument accuracy,
-
Product
PXIe Frequency Reference: 10 MHz And 100 MHz
M9300A
-
The M9300A PXIe frequency reference is a PXIe-compatible, compact, modular instrument that can be used with the Keysight M9301A synthesizer, M9310A source output, and M9311A modulator to create the world’s fastest vector signal generator, the M9381A. Create a CW source, the M9380A, by combining the M9300A with the M9301A and M9310A or use it as the 10-MHz or 100-MHz reference with other PXI solutions. Control the instrument through a soft front panel and programmatic interfaces tuned to your application development environment of choice.
-
Product
infra-red turbidity bench meter (NTU) with calibration kit
CyberScan TB 1000
-
The CyberScan TB1000 series turbidity meters (employing the Nephelometric non-ratio or NTU principle) are designed to meet stringent requirements of today's scientists. TB1000 series meet the performance criteria specified by USEPA method 180.1 for NTU measurement and ISO 7027 (IR version). Ideal for beverage production, drinking water, waste water treatment, petrochemical and electroplating applications.
-
Product
4-in-1 OSLT Calibration Kit, DC to 18 GHz, Type-N (f) 50 Ohm
CK519A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
RF Calibration Accessories
-
Employing good connector practice when using an RF calibrator not only avoids measurement errors and minimizes connector repeatability uncertainties but also reduces risk of damage to connectors and equipment. The 96000CONN and 9600CONN connector kits include a range of adapters and torque wrenches intended for use with the 96000 Series RF Reference Sources (9600CONN for the 96040A and 96000CONN for the 96270).The 9600CONN connector kit includes one each of 50 Ω and 75 N-Type male-female adapter for use with the 96000 Series levelling head as a “connector saver” or “sacrificial connector” to avoid risk of damage when making connections to UUT/DUT instruments.
-
Product
Trace-Level Dilution Calibrator
Model T700U
-
Teledyne Advanced Pollution Instrumentation
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.
-
Product
Passive Frequency Multipliers
-
The frequency multiplier which generates output with power level less than input power.
-
Product
Calibrator Process
VA70034
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Loop calibrator This Calibrator is use to measure or output 0 to 24 mA DC current loop, and 0 to 20 V DC voltage.
-
Product
Multi-Cal Pressure Calibrator
MC
-
Series MC Portable Multi-Cal Pressure Calibrator performs a wide variety of simple and complex pressure based measurement, test, and calibration operations. Modular sensor design allows user to select pressure measurement range for application flexibility.





























