Frequency Calibrators
-
Product
Electronic Ballast High Frequency Parameters Tester
UI2002A
-
• Measure Vrms, Irms, W, PF/Hz • Voltage range: 10~600V, Current range: 10~2000mA, Frequency range: 20~70kHz • Accuracy: Class 2
-
Product
Calibration Standards, Calibration Services
-
ISO 17015 traceable calibrated reference lamps, detectors and reflectors for the calibration and adjustment of sensors and measurement devices for light, optical radiation and light reflection. We offer as well many ISO 17025 calibration services.
-
Product
Proving Unit& Calibrators
-
Shanghai Beha Electronics Co., Ltd.
Calibration box is used to verify and proof any High Voltage Insulation Testers. It can be utilized to calibrate all High Voltage Insulation Testers very accurately Analogs or Digitals.
-
Product
Frequency Doubling Comb Generator
COMBGEN6DIFF
-
*Differential output - can also provide two separate single ended complementary outputs.*Pulse height of up to +4V peak into 50 ohms, on positive output*Pulse height of up to -4V peak into 50 ohms, on negative output*Rise time < 80pS, FWHM of approximately 120pS*Produces pulse on both edges of input clock, thereby doubling frequency.*Input clock may be sinewave from 50MHz to 2GHz or square wave from 5MHz to 2GHz, producing fundamental comb tooth energy from 10MHz to 4GHz.*Usable energy to >10GHz.*Can drive any load, including short, without damage.*Power Requirements: -12V @ 120mA and +24V @ 80mA
-
Product
Calibration Lead Precision Resistor - Dual
40-975-009-SL2
-
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
Digital/Analog Frequency Response Analyzer
8800 Series
-
The analyzer utilizes a digital “Sync” signal to provide synchronization between analog and digital hardware. The Model 8800 performs simultaneous analysis on both analog input channels and digital target processor, reliably capturing all data. Versatile by design, the Model 8800 digital interface can be disabled, via software, to use the analyzer in a standard 2-channel, analog-only configuration.
-
Product
Portable Vibration Calibrator
AT-2040
-
With AT-2040 you will find the features required for your application without having to install cumbersome and expensive addons. AT-2040 features a full-automatic sensitivity test mode, sensor simulation, power supply output for sensors that require voltage such as the 7310 and 991V aviation sensors, a built-in sensor charge amplifier for both single-ended and differential charge accelerometers, and a custom sensor input that can be configured to fit most accelerometers with a one to one cable.
-
Product
Torque Calibration
-
Calibration capabilities for torque applications range from 15 inch-ounces to 2,000 foot-pounds with electronically converted readings in every common unit of measure. NIST traceable weights and torsion arms provide traceability on all Process Instruments'' Torque Calibrations. Force gauges and torque transducers can also be calibrated with this system.
-
Product
33kHz and 200kHz Dual Frequency Transducer
Model TC2122
-
Model TC2122 is a 33kHz and 200kHz dual frequency transducer ideal for navigation and hydrographic echosounder systems. The transducer has excellent piezoceramic elements which will ensure the highest reliability and quality in echosounding. The transducer will fit Teledyne RESON SW 60/28/6029 housing and Teledyne RESON steel housings.
-
Product
High Frequency Current Transformer
HFCT
-
The HFCT is a high frequency current transformer designed specifically for picking up partial discharge signals. It has a split core ferrite to allow retrospective fitting to earth straps without the need for disconnection. The durable body has a hinge and a quick release latch, making use quick and easy. The HFCT is constructed with an aluminium body to provide RF shielding and improved performance in noisy environments.
-
Product
K-50 Series Probes
-
The K-50 coaxial probe provides an instrumentation-quality interface for broadband R.F. measurements up to 4 GHz. With the K-50 R. F. circuit design, impedance characterization measurements can be performed using it as a Network Analyzer port-extending accessory. Accurate and repeatable small signal and R.F. power (50 Watts) measurements provide consistent and repeatable results.
-
Product
AC Voltage and Frequency Transducers
NMTU/F
-
The NMTU/F device is an AC voltage and frequency transducer with two independent analogous outputs. The A output measures AC voltage, the B output measures the frequency of input voltage. That´s why one single NMTU/F transducer is able to replace two customary transducers, thus making it possible to achieve significant savings in installation space.
-
Product
Frequency Multipliers for Radio Amateurs
-
First approach is to generate the high frequency directly, at the fundamental, using an oscillatortuned on the desired frequency. Few sensitive issues appears here due to high working frequency as, stability, jitter, phase noise, pulling, pushing, low output power, and cost of the active component to meet the performances
-
Product
Frequency Converters & Transceivers
-
Mercury Systems’ converter and transceiver products are at the forefront of SWaP-optimized RF integrated products. Through substantial R&D investment and a library of building blocks, Mercury Systems has the capability to rapidly execute on the most complicated of custom transceiver designs. As the OpenVPX industry leader, Mercury Systems knows how to make integration into your system a breeze.
-
Product
Class 2 Sound Level Calibrator
SPC70
-
The SPC70 is a Class 2 sound level calibrator suitable for periodic testing of sound level meters and verifying their accuracy before and after readings, in accordance with international standards. The SPC70 is simple to use and provides a 1kHz reference at 94dB and 114dB. The output is accurate to 0.5dB with low levels of harmonic distortion. The SPC70 is compatible with the Martindale SP79 Class 2 Sound Level Meter and other meters with microphones up to 25mm.
-
Product
Dynamic Frequency Selection
-
MET is a leader in performing DFS testing on a variety of WLAN products for FCC, ISED, EU and Japan requirements.Many countries require wireless devices operating in unlicensed 5 GHz bands to have the capability to detect interference with other technology sharing the spectrum (such as military and weather radar systems) and automatically switch over to another frequency.
-
Product
Active Frequency Multipliers
-
The frequency multiplier which generates output signal with power greater than or equal to input power
-
Product
High Frequency Cartridge for HFP Series Probes
PACC-MS003
-
High Frequency Cartridge for HFP Series Probes
-
Product
Mercury Argon Calibration Source
HG-1
-
The compact, low-cost HG-1 Mercury Argon Calibration Source is a spectral wavelength calibration source for UV-VIS-Shortwave NIR spectrophotometric systems.
-
Product
Trace-Level Photometric Ozone Calibrator
Model T703U
-
Teledyne Advanced Pollution Instrumentation
The Model T703U is a microprocessor controlled ozone calibrator for precision gas analyzers. Expanded ozone audit levels have created a need for precise ozone calibration well below the capabilities of standard calibrators. The Model T703U is designed to meet the requirements of ultra-low ozone production.In addition to a high range with similar performance to the Model T703, the Model T703U has the capability to generate ozone in a low range, or "fractional" mode, for producing ozone levels down to 3 ppb, with exceptional accuracy. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperature and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703U, covering time periods up to a year.
-
Product
Handheld Economic Process Calibrator
VA701
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
This Multifunction calibrator combined voltage. current .resistance .thermocouple temperature .RTD in one device.
-
Product
FREQUENCY DISPLAY UNIT
TYPE NFD-1
-
The National RF Type NFD-1 Frequency Display Unit was designed for use with vintage and classic communications equipment, to display the received or transmitted radio frequency. The unit incorporates an internal processor that allows the intermediate frequency (IF) to be counted out by the frequency counter. The resultant display is the actual frequency that the equipment is receiving or operating at.
-
Product
Calibrators
-
A calibrator or process calibrator is used for basic measuring, testing and regulation techniques for setting and verifying test installations and instrumentation. PCE Instruments' calibrator products are lightweight yet made of durable materials. Our calibrator devices are easy to use and primarily handheld, though fixed installations are possible. A calibrator is valued by technicians due to its high level of accuracy and its universal range of applications.
-
Product
Calibrated Solar Reference Cell
-
To insure repeatable testing on any solar simulator, OAI offers 2cm x 2cm calibrated reference cells. Standard reference cell calibration cycles can be set up by OAI''s calibration laboratory to insure that your reference cell maintains certification.
-
Product
Calibrator/DVM Calibration
-
Measurements International Ltd.
Developed & designed by metrologists for metrologists & calibration technicians
-
Product
Acoustic Calibrators
-
When you're ready to take noise measurements, it's strongly recommended that you perform a field calibration using an Acoustic Calibrator. You should calibrate your sound meter before you start to measure, and then once you've finished you should perform a reference check against the calibrator and make note of any drift that has occured. You can find out more about performing Field Calibrators by reading this post and watching a short video.
-
Product
Low Frequency 2-Way Power Dividers To 3000 MHz
-
Power dividers from 4 kHz to 3 GHz are available from Pulsar Microwave in connectorized packages with SMA-female connectors, standard. This series is designed to handle 1 watt input power. They are designed for use in 50-ohm systems, and cover frequencies for VHF, UHF, Cell and PCS applications.
-
Product
Instrument Transformer Calibrators
CTPT 81
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
Product
Class 1 Sound Level Calibrator
HD2020
-
The HD2020 sound level calibrator is a portable, battery operated sound source, suitable for sound level meters (portable and laboratory) and acoustic stations.